Accounting for Optimal Control in the Sizing of Isolated Hybrid Renewable Energy Systems Using Imitation Learning

Authors: Simon HalvdanssonLucas Ferreira BernardinoBrage Rugstad Knudsen

Abstract

Decarbonization of isolated or off-grid energy systems through phase-in of large shares of intermittent solar or wind generation requires co-installation of energy storage or continued use of existing fossil dispatchable power sources to balance supply and demand. The effective CO2 emission reduction depends on the relative capacity of the energy storage and renewable sources, the stochasticity of the renewable generation, and the control of the isolated energy system. While the operation of the energy storage and dispatchable sources impacts the optimal sizing of the system, it is challenging to account for the effect of finite-horizon optimal control at the stage of system sizing. In this work, we present a flexible and computationally efficient sizing framework for energy storage and renewable capacity in isolated energy systems, accounting for uncertainty in the renewable generation and the optimal control. We implement an imitation learning approach to stochastic neural model predictive control (MPC) which allows us to relate the battery storage and wind peak capacities to the emissions reduction and investment costs while accounting for finite horizon, optimal control without solving an infeasible number of optimization problems. We evaluate the proposed sizing framework on a case study of an offshore energy system with a gas turbine, a wind farm and a battery energy storage system (BESS). In this case, we find a nonlinear, nontrivial relationship between the investment costs and the reduction in gas usage for different wind and BESS capacities.

Explore similar work

Sep 14, 2026math.OC

Towards Sustainable Hydrogen Systems: Supply Chain Optimization with Model Predictive Control and Reinforcement Learning

Hydrogen supply chains are expected to play a central role in future low-carbon energy systems by enabling renewable energy integration, long-duration storage, and decarbonization of industrial and transportation sectors. However, their operation is challenged by renewable generation variability, electricity price fluctuations, uncertain hydrogen demand, and engineering constraints associated with electrolyzers, energy storage, and grid interaction. As hydrogen infrastructure expands toward commercial deployment, operational strategies must balance economic performance, reliability, and sustainability under dynamic and uncertain conditions. This paper investigates and compares four control approaches for a renewable-powered hydrogen supply chain: a rule-based controller (RBC), model predictive control (MPC), reinforcement learning without forecasts (RL-NF), and reinforcement learning with forecast-augmented observations (RL-F). All methods are evaluated within a unified, physically realistic framework incorporating electrolyzer minimum-load and ramp-rate constraints, battery and hydrogen storage dynamics, grid import limits, and consistent economic assumptions, enabling a fair comparison under identical operating conditions. Simulation results show that MPC achieves the highest economic performance by exploiting short-term forecasts to coordinate storage, reduce grid dependence, and improve efficiency. RL-NF demonstrates robust and competitive performance without future information, highlighting the capability of learning-based methods to discover effective policies from experience. RL-F does not consistently outperform its no-forecast counterpart, suggesting that forecast uncertainty and increased state complexity can limit forecast-augmented learning. The results provide guidance for selecting operational control strategies in future hydrogen energy systems.
Mahammad Valiyev
Jun 14, 2026cs.NI

Hidden Degradation Costs in Energy-Cost-Only HEMS Optimisation: Study on Battery and PV Sensitivity

Residential battery energy storage systems (BESS) are increasingly deployed alongside photovoltaic (PV) generation to reduce household energy costs under volatile time-of-use (TOU) tariffs. Model predictive control (MPC) is a widely adopted optimisation strategy for home energy management systems (HEMS), typically formulated to minimise net energy cost, subject to physical and operational constraints. However, battery degradation is rarely embedded in the optimisation objective, meaning its cost is unquantified and aggressive; high-cycle-count strategies could incur significant losses once deployed to physical systems. This paper presents a receding-horizon mixed-integer linear programming (MILP) baseline for a UK residential HEMS, using demand data from the REFIT dataset. A 3 by 3 sensitivity study is conducted across three battery sizes and three PV array sizes, with post-hoc degradation cost estimated using the Naumann stress model and rainflow cycle counting. Results show that degradation remains constant for each battery size and can exceed energy cost savings by up to 1,060 %. These results demonstrate that energy-cost-only optimisation systematically underestimates the true system cost, motivating a degradation-aware control formulation.
Dawood Butt, Nandor Verba
May 23, 2026cs.AI

Emission-Aware Reinforcement Learning for Sustainable Electric Vehicle Charging and Carbon Dioxide Reduction Under Varying Renewable Penetration

The rapid growth of Electric Vehicle (EV) adoption challenges power distribution networks through peak load spikes, voltage instability, and transformer overloads from uncoordinated charging. While Model Predictive Control (MPC) and standard Reinforcement Learning (RL) methods have addressed these issues, existing approaches rarely treat real-time carbon intensity or fluctuating renewable energy (RE) availability as primary scheduling objectives, leaving substantial decarbonisation potential unrealised. This paper proposes an emission-aware RL strategy based on the Soft Actor Critic (SAC) algorithm, with a multi-objective reward that penalises carbon emissions, curtailed on-site renewables, and unmet user demand. The agent is trained within a unified benchmarking framework on the EV2Gym platform, incorporating behind-the-meter solar and wind profiles, time-varying EirGrid carbon intensity data, and realistic workplace EV behaviour across 25 Electric Vehicle Supply Equipment (EVSE) units. Nine control strategies, including heuristics, emission-aware MPC variants, and the proposed RL agent, are compared under five renewable penetration scenarios (0%-50%) over ten independent runs each. The RL agent achieves a carbon intensity as low as 23.96 grams of carbon dioxide per kilowatt-hour under 50% wind penetration, representing up to 87% emission reduction versus the uncontrolled baseline, and outperforms the external graph-based Power Distribution Network (PDN) benchmark. Transformer overload remains below 7 kWh across scenarios, against up to 1093 kWh for the As Fast As Possible (AFAP) heuristic, and renewable self-consumption reaches 52% under combined wind and solar supply. Embedding carbon intensity forecasts into the RL state and reward aligns charging with low-emission periods while preserving grid compliance and user satisfaction.
Ninglin Ou, Mohammad A. Razzaque, Iftekher Islam Shovon +5