cs.ROMar 16, 2026

A Unified Calibration Framework for Coordinate and Kinematic Parameters in Dual-Arm Robots

Authors: Tianyu Huang, Bohan Yang, Bin Li, Wenpan Li, Haoang Li, Wenlong Li, Yun-Hui Liu

Organizations: Hong Kong Centre for Logistics Robotics and Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China · State Key Laboratory of Intelligent Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China · Thrust of Robotics and Autonomous Systems, The Hong Kong University of Science and Technology (Guangzhou), Guangzhou, China

Abstract

Precise collaboration in vision-based dual-arm robot systems requires accurate system calibration. Recent dual-robot calibration methods have achieved strong performance by simultaneously solving multiple coordinate transformations. However, these methods either treat kinematic errors as implicit noise or handle them through separated error modeling, resulting in non-negligible accumulated errors. In this paper, we present a novel framework for unified calibration of the coordinate transformations and kinematic parameters in both robot arms. Our key idea is to unify all the tightly coupled parameters within a single Lie-algebraic formulation. To this end, we construct a consolidated error model grounded in the product-of-exponentials formula, which naturally integrates the coordinate and kinematic parameters in twist forms. Our model introduces no artificial error separation and thus greatly mitigates the error propagation. In addition, we derive a closed-form analytical Jacobian from this model using Lie derivatives. By exploring the Jacobian rank property, we analyze the identifiability of all calibration parameters and show that our joint optimization is well-posed under mild conditions. This enables off-the-shelf iterative solvers to stably optimize these parameters on the manifold space. Besides, to ensure robust convergence of our joint optimization, we develop a certifiably correct algorithm for initializing the unknown coordinates. Relying on semidefinite relaxation, our algorithm can yield a reliable estimate whose near-global optimality can be verified a posteriori. Extensive experiments validate the superior accuracy of our approach over previous baselines under identical visual measurements. Meanwhile, our certifiable initialization consistently outperforms several coordinate-only baselines, proving its reliability as a starting point for joint optimization.

Figures & tables

Explore similar work

May 6, 2026

Optimal Uncertainty-Aware Calibration for the AX=YB Problem

This article proposes a general optimization framework for solving hand-eye calibration problem. Unlike traditional methods, an iterative algorithm based on Lie algebra that achieves approximately global optimal solutions is developed. During the optimization process, the method strictly preserves the structural constraints of the calibration parameters and enables synchronized updates between calibration parameters. Recognizing that data used in real-word hand-eye calibration often contain uncertainty, especially in over-loading and large workspace industrial robot scenarios, which can significantly degrade accuracy, and accurately modeling such uncertainty is inherently difficult, this article avoids explicit uncertainty modeling. Instead, an uncertainty metric to evaluate the relative uncertainty between data sources is introduced and used to dynamically refine the iterative process. To further enhance convergence efficiency, an effective initial solution generation method that improves overall stability and accuracy is designed. Numerical simulations and real-world experiments validate the effectiveness of the proposed approach, and in synthetic datasets, the proposed approach improves the estimation accuracy by at least 67% under high-uncertainty conditions compared with the existing methods.
Apr 17, 2026

Diffusion-Based Optimization for Accelerated Convergence of Redundant Dual-Arm Minimum Time Problems

We present a framework leveraging a novel variant of the model-based diffusion algorithm to minimize the time required for a redundant dual-arm robot configuration to follow a desired relative Cartesian path. Our prior work proposed a bi-level optimization approach for the dual-arm problem, where we derived the analytical solution to the lower-level convex sub-problem and solved the high-level nonconvex problem using a primal-dual approach. However, the gradient-based nature leads to a large computation overhead, and it prohibits directly imposing an L∞L_{\infty} Cartesian error constraint along the joint trajectory due to the sparsity of the gradient. In this work, we propose a diffusion-based framework that relies on probabilistic sampling to tackle the aforementioned challenges in the nonconvex high-level problem, leading to a 35x reduction in the runtime and 34% less Cartesian error compared to our prior work.
Sep 17, 2026

OmniCalib: Target-Free, Task-Structured Self-Calibration for Humanoid Robots

Assembly, wear, and component replacement perturb the sensor extrinsics and joint zeros encoded by a humanoid CAD model. Existing procedures calibrate one sensor pair or require external fiducials. Using only robot-native motion and onboard sensing, we present OmniCalib, a target-free workflow that calibrates the full upper limbs---all 14 arm joint zeros and the extrinsics of both wrist and chest cameras---as well as lower limbs and the multi-camera head rig. Each module matches a robot-native task to a parameter block, checks observability, and writes only supported corrections to the CAD model. Our depth ICP method recovers all 14 arm joint zeros and calibrates all RGB-D camera extrinsics without any calibration target. Relative to CAD, the estimated extrinsic corrections are 10.56 mm and 1.74 degrees for the left wrist, 6.33 mm and 1.25 degrees for the right wrist, and 9.81 mm and 0.929 degrees for the chest RGB-D camera. ICP point-to-plane residual is 2.09 mm. On the same injected offsets, ICP and ArUco recover all 14 joint zeros below the 0.1-degree encoder-resolution reference. On an AGIBOT A3 Ultra humanoid, four static double-support stances recover all 12 lower-limb joint-zero offsets injected with an RMS error of 0.063 degrees. The head module combines multi-camera visual odometry with legged odometry and dynamic compensation through the live ROS transform tree. Using only planar walking, it attains a mean SO(3) error of 1.061 degrees across three sequences. The best sequence reaches 0.775 degrees, competitive with iKalibr at 0.902 degrees from rich 6-DOF excitation. Rig-relative angles repeat within 0.140 degrees. Injection recovery and held-out tests validate each observable block.