cs.LGMar 20, 2026

Detecting Neurovascular Instability from Multimodal Physiological Signals Using Wearable-Compatible Edge AI: A Responsible Computational Framework

Authors: Truong Quynh Hoa, Hoang Dinh Cuong, Truong Xuan Khanh

Organizations: H&K Research Studio, Clevix LLC, Hanoi, Vietnam · the Department of Cardiology, Hanoi Heart Hospital, Hanoi, Vietnam

Abstract

We propose Melaguard, a multimodal ML framework (Transformer-lite, 1.2M parameters, 4-head self-attention) for detecting neurovascular instability (NVI) from wearable-compatible physiological signals prior to structural stroke pathology. The model fuses heart rate variability (HRV), peripheral perfusion index, SpO2, and bilateral phase coherence into a composite NVI Score, designed for edge inference (WCET <=4 ms on Cortex-M4). NVI - the pre-structural dysregulation of cerebrovascular autoregulation preceding overt stroke - remains undetectable by existing single-modality wearables. With 12.2 million incident strokes annually, continuous multimodal physiological monitoring offers a practical path to community-scale screening. Three-stage independent validation: (1) synthetic benchmark (n=10,000), AUC=0.88 [0.83-0.92]; (2) clinical cohort PhysioNet CVES (n=172; 84 stroke, 88 control) - Transformer-lite achieves AUC=0.755 [0.630-0.778], outperforming LSTM (0.643), Random Forest (0.665), SVM (0.472); HRV-SDNN discriminates stroke (p=0.011); (3) PPG pipeline PhysioNet BIDMC (n=53) -- pulse rate r=0.748 and HRV surrogate r=0.690 vs. ECG ground truth. Cross-modality validation on PPG-BP (n=219) confirms PPG morphology classifies cerebrovascular disease at AUC=0.923 [0.869-0.968]. Multimodal fusion consistently outperforms single-modality baselines. Code: https://github.com/ClevixLab/Melaguard

Figures & tables

Explore similar work

Apr 12, 2026

Sense Less, Infer More: Agentic Multimodal Transformers for Edge Medical Intelligence

Edge-based multimodal medical monitoring requires models that balance diagnostic accuracy with severe energy constraints. Continuous acquisition of ECG, PPG, EMG, and IMU streams rapidly drains wearable batteries, often limiting operation to under 10 hours, while existing systems overlook the high temporal redundancy present in physiological signals. We introduce Adaptive Multimodal Intelligence (AMI), an end-to-end framework that jointly learns when to sense and how to infer. AMI integrates three components: (1) a lightweight Agentic Modality Controller that uses differentiable Gumbel-Sigmoid gating to dynamically select active sensors based on model confidence and task relevance; (2) a Learned Sigma-Delta Sensing module that applies patch-wise Delta-Sigma operations with learnable thresholds to skip temporally redundant samples; and (3) a Foundation-backed Multimodal Prediction Model built on unimodal foundation encoders and a cross-modal transformer with temporal context, enabling robust fusion even under gated or missing inputs. These components are trained jointly via a multi-objective loss combining classification accuracy, sparsity regularization, cross-modal alignment, and predictive coding. AMI is hardware-aware, supporting dynamic computation graphs and masked operations, leading to real energy and latency savings. Across MHEALTH, HMC Sleep, and WESAD datasets, it reduces sensor usage by 48.8% while improving state-of-the-art accuracy by 1.9% on average.
Aug 7, 2026

CFD-Guided Detection of Concept Drift in Multimodal Physiologic Signals

Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration. This paper asks when a model should keep its prediction, change it, or flag uncertainty. We propose a physiologic stability framework, called PECS, that compares changes inside the model with measurable changes in the signal. ECG is treated as the main cardiac signal, photoplethysmography (PPG) adds pulse and vascular information, and respiration is used only when ECG and PPG disagree. We test the framework on PTB-XL at pilot and full scales and on synchronized BIDMC and MIMIC waveform cohorts. The PTB-XL pilot and full- scale analyses selected different domain pairs, and the strongest cross-modal pair also changed across BIDMC and MIMIC, showing that adding every available signal is not always the best choice. PECS outperformed the evaluated drift-detection baseline implementations, reaching drift classification accuracy (DCA) of 0.8786 on expanded BIDMC and 0.9560 on MIMIC. The MIMIC results also showed that respiration can help during disagreement cases, but it should be used selectively rather than as an automatic override. Overall, the results support PECS as a candidate monitoring framework for wearable cardiovascular AI while highlighting the need for scale-aware domain selection and interpretable trust routing
Oct 27, 2026

MM-Net: A Multimodal Multi-Task Network for Sleep Staging and Sleep Apnea Assessment After Ischemic Stroke

Automated polysomnography after ischemic stroke is challenging because of altered sleep-related neural activity and concurrent respiratory disturbances. Existing stroke-specific approaches mainly address sleep-stage classification, leaving joint analysis of sleep architecture and respiratory events underexplored. Moreover, adapting pretrained EEG encoders introduces a representation inconsistency when downstream models are trained on embeddings from previously seen patients but evaluated on unseen individuals. We propose MM-Net, a multimodal multi-task framework that resolves this inconsistency through cross-fitting and ridge-based embedding alignment. Sleep-adapted EEG-EOG representations and engineered neural descriptors are fused with learned cardiorespiratory features through cross-attention and shared temporal modeling for simultaneous sleep staging and respiratory-event detection. On iSLEEPS (99 patients with subacute ischemic stroke), ten-fold patient-independent evaluation achieved 76.3% staging accuracy (Cohen's κκ = 0.656) and 0.825 respiratory-event AUC, outperforming the evaluated baselines under matched protocols. The sleep-adapted encoder improved the downstream model when its embeddings were aligned, raising staging accuracy by 1.4 percentage points over the frozen encoder (pp = 0.020) versus 0.2 points without alignment. MM-Net also achieved 86.4% staging accuracy on Sleep-EDF, above every single-EEG architecture reimplemented on the same recordings, and 80.3% staging accuracy with 0.889 respiratory AUC on ISRUC-I, exceeding its retrained staging baselines. Without retraining, the iSLEEPS-trained model retained respiratory AUCs of 0.833 on ISRUC-I and 0.841 on UCD. These findings support representation-consistent neural adaptation and joint physiological modeling across stroke, healthy-sleep, and sleep-disorder cohorts.