cs.CVApr 11, 2026

Global monitoring of methane point sources using deep learning on hyperspectral radiance measurements from EMIT

Authors: Vishal V. Batchu, Michelangelo Conserva, Alex Wilson, Anna M. Michalak, Varun Gulshan, Philip G. Brodrick, Andrew K. Thorpe, Christopher V. Arsdale

Organizations: Google Research · Carnegie Institution for Science · Jet Propulsion Laboratory, California Institute of Technology

Abstract

Anthropogenic methane (CH4) point sources are critical drivers of near-term climate forcing, safety hazards, and system-inefficiencies. Space-based imaging spectroscopy is an emerging tool for identifying emissions globally, but existing approaches largely rely on manual plume identification. Here, we present the Methane Analysis and Plume Localization with EMIT (MAPL-EMIT) model, an end-to-end vision transformer framework that leverages the complete radiance spectrum from the Earth Surface Mineral Dust Source Investigation (EMIT) instrument to jointly retrieve methane enhancements across all pixels within a scene. This approach brings together spectral information with spatial context to significantly lower detection limits. MAPL-EMIT simultaneously supports enhancement quantification, plume delineation, and source localization, even for overlapping plumes. The model was trained on 3.6 million physics-based synthetic plumes injected into global EMIT radiance data. Synthetic evaluation confirms the model's ability to identify plumes with high recall and precision and to capture weaker plumes relative to existing matched-filter approaches. On real-world benchmarks, MAPL-EMIT captures 84% of known hand-annotated NASA-L2B plume complexes across a test set of 1084 EMIT granules, while capturing roughly 1.5 times as many plausible plumes compared to human analysts. Further verification against coincident airborne data, top-emitting landfills, and controlled release experiments confirms the model's ability to identify previously uncaptured sources. By incorporating model-generated metrics such as spectral fit scores and estimated noise levels, the framework can limit false-positives. Overall, MAPL-EMIT enables high-throughput implementation on the full EMIT data catalog, shifting methane monitoring to a rapid, scalable paradigm for global plume mapping at the facility scale.

Explore similar work

May 5, 2026

Fully Automatic Trace Gas Plume Detection

Future imaging spectrometers will increase data volumes by orders of magnitude, requiring automated detection of trace gas point sources. We present a fully automated framework that combines machine learning-based morphological analysis with physics-based spectroscopic fitting to detect plumes without human participation. Applied to EMIT imaging spectrometer data, the system operates in two modes: "daily digest" that runs automatically on all downlinked data, flagging the largest events for immediate response, and a retrospective analysis that identifies plumes missed by prior human review. The daily digest demonstrates that a significant fraction of the largest plumes can be detected automatically with negligible false positives, while retrospective analysis suggests at least 25% of plumes may have been overlooked. In addition to the previously observed methane point sources, we extend detection to three understudied trace gases: NH3, NO2 and the first observations of carbon monoxide (CO) plume in EMIT imagery.
Jun 24, 2026

Methane-Plume Segmentation From Hyperspectral Satellite Imagery Via Multimodal Deep Learning

Efficient detection of methane plumes is crucial for understanding and mitigating global warming, as accurately identifying and segmenting them in earth observation imagery remain essential for large-scale monitoring. In this work, we propose a multimodal deep learning model that integrates a feature-guided methane enhancement (FGME) mechanism which injects physically meaningful methane cues into transformer-based RGB representations at multiple semantic scales. Our method is evaluated on the MPDataset, where it outperforms the state-of-the-art with improvements of +0.92 in MIoU, +0.87 in MPrecision and +1.01 in Recall. Notably, these gains are obtained with a substantially lower computational cost than other high-performing architectures, resulting in a favorable accuracy-efficiency trade-off for large-scale methane monitoring. These results highlight the potential of efficient multimodal fusion strategies for accurate and scalable methane plume segmentation in real-world remote sensing applications.
May 22, 2026

Plume Segmentation from MethaneSAT with Cross-Sensor Transfer Learning and Physics-Informed Postprocessing

Automated detection and masking of individual methane plumes from satellite imagery is important for operational emission attribution and quantification. We present a machine learning framework for plume detection from MethaneSAT retrieved column-averaged dry-air mole fractions of methane. We address two core challenges: the scarcity of labeled MethaneSAT data and the need for inference reliability across diverse atmospheric and surface conditions. We first demonstrate that Mask R-CNN with a ResNet-50 backbone outperforms a U-Net semantic segmentation baseline on both MethaneAIR (an airborne version of MethaneSAT) and MethaneSAT data, with pixel-level F1 score gains of 10.49 and 5.48 percentage points respectively. To address MethaneSAT data scarcity, we evaluate three cross-sensor transfer strategies leveraging MethaneAIR flights and synthetic plumes. Mask R-CNN with ResNet-50 fine-tuned from MethaneAIR pre-trained weights is the most effective strategy, achieving instance-level precision of 0.60 and recall of 0.98 at the baseline operating point. A physics-informed post-processing pipeline converts detections into two operationally distinct modes. The first is a high-sensitivity mode that applies morphological filtering and proximity-based merging for comprehensive emission screening, achieving precision of 0.71 and recall of 0.94. The second is a high-precision mode that additionally applies a distribution-based classifier for confident source attribution, achieving precision of 0.92 and recall of 0.70. Manual review of detections classified as false positives against our wavelet-based reference plume mask labels shows that some correspond to real methane enhancements... Our data and code used in this work are publicly available at: https://doi.org/10.7910/DVN/FR959H