Abstract
Partial Differential Equation (PDE)-based approaches have gained significant attention in image despeckling due to their strong capability to preserve structural details while suppressing noise. However, conventional second-order PDE models tend to generate blocky artifacts, whereas higher-order models often introduce speckle patterns. To resolve it, this paper proposes and comparatively analyzes two advanced PDE-based frameworks designed for speckle noise suppression while preserving the fine edges. The first model introduces a novel weighted formulation that combines second and fourth-order PDEs through a weighting parameter. The second-order diffusion coefficient employs grayscale and gradient-based indicators, while the fourth-order term is guided solely by a Laplacian-based indicator. The second model constructs a coupled PDE framework, where independent fourth and second-order components are explicitly solved in an iterative manner. In this coupled structure, each diffusion coefficient is defined separately to enhance adaptability in varying image regions. Both models are implemented using the explicit finite difference method. The proposed techniques are extensively evaluated on a variety of datasets, including standard grayscale, color, Synthetic Aperture Radar (SAR), and ultrasound images. Comparative experiments with the existing Telegraph Diffusion Model (TDM) and Fourth-Order Telegraph Diffusion Model (TDFM) demonstrate the superiority of the proposed approaches in reducing speckle noise while effectively preserving fine image structures and edges. Quantitative evaluations using PSNR, SSIM and Speckle Index metrics confirm that the proposed models produce higher image quality and enhanced visual perception. Overall, the presented PDE-based formulations provide a reliable and efficient framework for image despeckling in both natural and medical imaging.
Speckle noise severely limits the quality of images acquired from coherent imaging systems such as Synthetic Aperture Radar (SAR) and medical ultrasound. Traditional second-order PDE-based despeckling approaches, although popular, often introduce staircase artifacts and blur fine details. To overcome these limitations, we present a nonlinear, fourth-order coupled hyperbolic-parabolic PDE model that effectively reduces noise while preserving the structure. The framework consists of two evolution equations: one governing fourth-order diffusion for effective speckle reduction and smooth intensity transitions, and another refining an edge indicator to protect textures and structural features. The diffusion coefficient is adaptively constructed using both the image intensity variable u and a grayscale-based indicator function, ensuring structure-aware denoising while avoiding blocky artifacts and preserving fine details. We also prove the existence of a weak solution to the proposed model by applying Schauder fixed-point theorem. A finite-difference scheme with Gauss Seidel iteration is employed for efficient implementation. We compare the proposed model with the existing coupled second-order PDE model (HPCPDE) and the fourth-order telegraph diffusion model (TDFM). The results show that our model consistently outperforms these approaches. Experiments on standard grayscale images, real SAR and ultrasound data, as well as speckle-corrupted color images, demonstrate that the proposed method achieves superior performance over conventional PDE-based techniques in terms of PSNR, MSSIM, and Speckle Index.
In real-world scenarios, image defogging is an inverse problem due to unknown scene depth, atmospheric scattering, and the common absence of ground truth . To resolve the issue, we propose a hybrid defogging model that integrates a fourth-order nonlinear PDE with a physical haze formation model. We used Dark Channel Prior to estimate atmospheric parameters and to generate a guidance image, while the final restoration is performed via a fourth-order PDE-based evolution. A fourth-order PDE of the type telegraph is then evolved, incorporating an edge-adaptive diffusion coefficient and a fidelity term weighted by the transmission map. Fourth-order diffusion effectively suppresses haze while preserving structural details, and the hyperbolic formulation improves numerical stability and convergence behavior. We use relative error norm criteria for the convergence of our PDE. The proposed method is compared with Dark Channel prior, modified Dark Channel prior, and variational-based single-image defogging techniques. When we have ground truth available, we use MSE and SSIM for quantitative evaluation, whereas no-reference metrics, including FADE, Contrast Restoration Index, Average Gradient, and Entropy, are applied to real-world foggy images. Experimental results demonstrate that the proposed hybrid PDE-based method provides comparable visual quality and maintains structural details.
Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservation of anatomical structures. Although recently developed despeckling methods have achieved some progress, supervised learning approaches remain fundamentally limited by the ground truth paradox, which arises from the absence of noise-free, ground truth reference images in in vivo scenarios. Existing unsupervised diffusion-based methods typically enforce data consistency directly in the nonlinear log-compressed domain, which can disproportionately amplify background artifacts when mapped back to the envelope domain. To overcome these limitations, we propose an uncertainty-guided null-space diffusion (UGNS) framework, a novel label-free solution that enforces consistency correction on a stabilized positive-envelope proxy obtained via inverse log compression. The proposed UGNS introduces several technical novelties: (a) extraction of a structural prior in the stabilized envelope domain to produce a robust signal envelope that preserves anatomical structure, (b) development of an adaptive range-null reconstruction mechanism that uses an adaptive weight mask to preserve tissue regions via range-space projection, and (c) introduction of uncertainty-guided fusion in an adaptive way to mitigate sampling variability. Extensive and comparative experiments were conducted using the PICMUS benchmark and in vivo datasets. The results demonstrate that UGNS achieves competitive generalized contrast-to-noise ratio (gCNR) values across diverse datasets. In addition, it is successfully validated that UGNS effectively suppresses speckle noise while preserving fine spatial resolution. Code is available at https://github.com/yousirong/UGNS.git.