eess.SPMay 13, 2026

Compact Latent Manifold Translation: A Parameter-Efficient Foundation Model for Cross-Modal and Cross-Frequency Physiological Signal Synthesis

Authors: Bo CuiXiaowen SongYaowen ZhangShunzhe ZhangB. J. F. van BeijnumMonique TabakYing Wang

Organizations: Department of Biomedical Signals and Systems University of Twente · Department of Applied Mathematics University of Twente

Abstract

The analysis of physiological time series, such as electrocardiograms (ECG) and photoplethysmograms (PPG), is persistently hindered by modality and frequency gaps stemming from heterogeneous recording devices. Existing foundation models typically rely on continuous latent spaces, which frequently suffer from severe modality entanglement, lack high-fidelity cross-frequency generative capacity, and impose high computational costs that prohibit edge-device deployment. In this paper, we propose Compact Latent Manifold Translation (CLMT), a highly parameter-efficient (0.09B) unified framework that bridges these gaps through a novel two-stage discrete translation paradigm. First, we introduce a Universal Tokenizer utilizing Hierarchical Residual Vector Quantization (RVQ) to decouple heterogeneous signals into isolated, well-structured discrete latent manifolds, effectively preventing inter-modality interference. Second, a Context-Prompted Latent Translator maps these discrete tokens across modalities by integrating static physiological priors, reframing complex signal synthesis as a pure latent sequence translation task. Extensive evaluations demonstrate that our 0.09B model significantly outperforms massive baselines. In cross-modal PPG-to-ECG synthesis, it resolves temporal phase drift and dramatically improves the clinical R-peak detection F1-score from 0.37 (baseline) to 0.83. Furthermore, in extreme cross-frequency super-resolution (25Hz to 100Hz), it successfully recovers high-frequency diagnostic landmarks, achieving an unprecedented Pearson correlation of 0.9956. By learning a universal discrete language for biological signals with a fraction of the computational footprint, our approach sets a new trajectory for edge-deployable, multi-modal medical foundation models.

Explore similar work

Aug 13, 2026cs.LG

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.
Hamza Shafiq, Hung Manh Pham, Bin Zhu +3
May 10, 2026cs.LG

Biosignal Fingerprinting: A Cross-Modal PPG-ECG Foundation Model

Cardiovascular disease remains the leading cause of global mortality, yet scalable cardiac monitoring is hindered by the gap between diagnostic-rich ECG and ubiquitous wearable PPG. Bridging this gap requires representations that are compact, transferable across modalities and devices, and deployable without task-specific retraining. Here we introduce biosignal fingerprints: compact latent representations of cardiovascular state derived from a cross-modal foundation model, the Multi-modal Masked Autoencoder (M2AE), trained on over 3.4 million paired ECG and PPG signals. M2AE integrates modality-specific encoders with a shared bottleneck and dual decoders, jointly optimized using reconstruction and cross-modal contrastive objectives, yielding generalizable fingerprints that retain intra- and inter-modality features. Like a biometric fingerprint, these representations uniquely encode an individual's cardiovascular state in a modality-agnostic, privacy-preserving form reusable across clinical tasks without exposing raw waveform data or requiring model retraining. Across 7 downstream tasks, spanning cross-modal reconstruction, cardiovascular disease classification, hypertension detection, mortality prediction, and demographic inference, biosignal fingerprints achieve competitive or superior performance compared to leading domain-specialist foundation models in frozen settings, including an AUROC of 0.974 for five-class CVD classification and 0.877 for hypertension detection, with a maximum improvement of 27.7% in AUROC across 5 classification tasks. Critically, strong performance is maintained with only a single modality, enabling deployment in resource-constrained, single-sensor environments typical of real-world wearable monitoring, with direct implications for continuous cardiovascular monitoring across clinical and consumer health settings.
Zhangdaihong Liu, Chang Liu, Fenglin Liu +4
Jun 20, 2026cs.LG

SPOTR: Spatio-temporal Pooling One-Token Reconstruction for Universal Physiological Signal Self-supervised Learning

Physiological signals such as EEG, ECG, and PPG are widely used in clinical monitoring. Recent self-supervised learning (SSL) methods offer an attractive way to leverage unlabeled recordings, yet they still fall short in practice. In particular, current SSL methods struggle across heterogeneous datasets, often distorting clinically meaningful structures or learning shortcuts from temporal and cross-channel redundancy. Consequently, existing SSL methods often deliver limited performance under linear probing, a lightweight adaptation setting that better matches real-world medical scenarios. Moreover, most Transformer-based SSL models encode a flattened spatiotemporal token sequence, incurring high computation and memory cost, and are typically developed within a single modality. To address these limitations, we present SPOTR (Spatio-temporal Pooling One-Token Reconstruction), a compress-reconstruct pretraining framework that introduces a single-token global bottleneck for physiological signals. SPOTR compresses each waveform into a single-token representation and reconstructs the signal conditioned only on this representation. Meanwhile, SPOTR introduces an efficient spatio-temporal compaction module to reduce computation and memory cost. Pretrained on 20 datasets spanning EEG, iEEG, ECG, and PPG, SPOTR consistently outperforms the strongest baseline under linear probing, improving average AUC by 18.49%, 21.71%, 17.86%, and 4.64%, respectively. Compared with a representative general-purpose time-series foundation model, SPOTR achieves around 78% lower latency and 52% lower peak GPU memory on average. The code can be found at https://github.com/5GYYYYY/SPOTR.
Yiyu Gui, Mingzhi Chen, Yuesheng Zhu +2