cs.CVMay 17, 2026

GraphMAR: Geometry-Aware Graph Learning Framework for Spatially Adaptive CT Metal Artifact Reduction

Authors: Zilong LiChenglong MaYiming LeiYuanlin LiJing HanJiannan LiuHuidong XieJunping Zhang+2 more

Abstract

Computed tomography (CT) metal artifact reduction (MAR) aims to reduce the severe streaking artifacts induced by metallic implants and other high-density objects. Effective MAR generally requires both accurate artifact localization and artifact removal. Sinogram-domain methods can exploit explicit geometric cues, such as metal traces, to identify metal-corrupted measurements, while requiring raw projection data, which is often unavailable in clinical and practical scenarios. Image-domain methods are more flexible and widely applicable, yet they usually lack comparable geometric guidance, limiting their ability to localize artifacts and leading to suboptimal results. To address this limitation, we propose GraphMAR, a geometry-aware learning framework for explicit artifact identification and spatially adaptive MAR in the image domain. The key idea is to introduce graph-based geometric modeling as an image-domain analogue of sinogram metal traces. Specifically, we first construct a geometric graph from the metal mask and derive a geometric density graph that coarsely localizes artifact-prone regions according to inter-implant geometry. We then design GraphMoE, a graph-routed mixture-of-experts module that builds a polar-coordinate artifact graph in feature space and adaptively routes different experts to different spatial regions for MAR. By aligning the learned routing maps with the geometric density graph, GraphMAR provides explicit and interpretable artifact localization while enabling region-adaptive artifact reduction. Experiments on both simulated and real-world datasets demonstrate that GraphMAR achieves superior MAR performance compared with existing methods. To the best of our knowledge, this is the first work to introduce graph-based modeling for CT MAR and to enable explicit artifact identification in the image domain, improving both restoration quality and interpretability.

Explore similar work

Jul 30, 2026cs.CV

SCMA: Structure-Conditioned and Metal-Aware Flow Matching for CT Metal Artifact Reduction

In X-ray CT, metallic objects cause beam hardening, photon starvation, and scattering, leading to projection inconsistency, streaks, dark bands, and structural distortions that compromise clinical diagnosis and quantitative analysis. Existing metal artifact reduction (MAR) methods remain limited: optimization-based methods may leave residual artifacts or blur structures, regression networks may generalize poorly across scenarios, and generative models without sample-specific structural guidance and physical constraints may produce anatomically inconsistent structures. Flow Matching learns a continuous-time velocity field that deterministically transports a source distribution to a target distribution, providing a flexible MAR prior. However, standard unconditional Flow Matching does not exploit sample-specific structure, spatially nonuniform metal-induced degradation, or measured projections. To address these limitations, we propose SCMA, a structure-conditioned and metal-aware Flow Matching framework. First, a linear-interpolation-corrected image is fed into the velocity network with the intermediate state as a sample-specific structural condition, guiding inference toward artifact-free CT images while preserving anatomy. Second, time-varying spatial weights from the metal mask and its distance transform are incorporated into the Flow Matching loss to emphasize severe degradation within and around metal regions. Finally, conditional Flow Matching updates alternate with projection-consistency correction during inference, allowing reliable measurements outside metal traces to constrain predictions. Experiments on simulated and real CT data demonstrate that SCMA more effectively suppresses metal artifacts, preserves local anatomical structures, and reduces hallucination-like structures inconsistent with projection measurements than representative MAR methods.
Heran Wang, Jianing Sun, Xu Jiang +3
May 12, 2026cs.CV

H3D-MarNet: Wavelet-Guided Dual-Path Learning for Metal Artifact Suppression and CT Modality Transformation for Radiotherapy Workflows

Metal artifacts in computed tomography (CT) severely degrade image quality, compromising diagnostic accuracy and radiotherapy planning, especially in cancer patients with high-density implants. We propose H3D-MarNet, a two-stage framework for artifact-aware CT domain transformation from kilo-voltage CT (kVCT) to mega-voltage CT (MVCT). In the first stage, a wavelet-based preprocessing module suppresses metal-induced artifacts through frequency-aware denoising while preserving anatomical structures. In second stage, Domain-TransNet performs kVCT-to-MVCT domain transformation using a hybrid volumetric learning architecture. Domain-TransNet integrates a CNN-based encoder to capture fine-grained local anatomical details and a transformer-based encoder to model long-range volumetric dependencies. The complementary representations are fused through an attention-based feature fusion mechanism to ensure spatial and contextual coherence across slices. A multi-stage, attention-guided decoder, supported by deep supervision, progressively reconstructs artifact-suppressed MVCT volumes. Extensive experiments demonstrate that H3D-MarNet achieves 28.14 dB PSNR and 0.717 SSIM on artifact-affected slices from full dataset, indicating effective metal artifact suppression and anatomical preservation, highlighting its potential for reliable CT modality transformation in clinical radiotherapy workflows.
Mubashara Rehman, Niki Martinel, Michele Avanzo +2
Aug 5, 2026cs.CV

Splat-Based Metal Artifact Reduction in Cone-Beam CT via Compact Attenuation Modeling

X-ray computed tomography (CT) suffers from severe metal artifacts when high-attenuation objects such as dental fillings or orthopedic implants are present. These artifacts originate from the polychromatic nature of X-rays, where attenuation varies strongly with photon energy and material composition, breaking the monochromatic assumption used by conventional reconstruction algorithms. Recent neural rendering approaches attempt to address this mismatch through differentiable polychromatic projection models, but they still struggle with smoothness bias, loss of fine structures, and prohibitive computation when extended to large-scale cone-beam CT. We introduce a splat-based metal artifact reduction framework that incorporates a physically grounded polychromatic forward model into a continuous Gaussian representation for cone-beam CT. Each Gaussian encodes the energy-dependent attenuation of the underlying material using a compact material parameterization, which enables efficient joint optimization of geometric and material properties without relying on a metal mask. This compact attenuation formulation captures the essential variation across biological tissues and metallic implants, allowing our model to explain metal-induced nonlinearity while preserving high-frequency structure. Experiments on simulated and real cone-beam CT scans show that our method converges significantly faster and suppresses metal artifacts more effectively than existing reconstruction and neural field-based approaches.
Kiseok Choi, Jaemin Cho, Inchul Kim +1