Generation of Heterogeneous PET Images from Uniform Organ Activity Maps Using a Pretrained Domain-Adapted Diffusion Model
Authors: Suya Li, Kaushik Dutta, Debojyoti Pal, Jingqin Luo, Kooresh I. Shoghi
Abstract
Synthetic PET images are valuable for quantitative imaging workflow development, scalable virtual imaging trials, and deep learning model training, but conventional physics-based simulation approaches are computationally intensive, limited in anatomical variability, and often fail to capture heterogeneous PET uptake. This study developed a pretrained domain-adapted diffusion (PAD) model for anatomy-conditioned PET synthesis from uniform organ activity maps. PAD adopts a natural-image pretrained text-to-image decoder with an upstream conditioning encoder and a downstream PET-domain adapter. A two-phase training strategy was used, with the first phase learning coarse uptake distributions and the second refining local image details. Uniform organ activity maps were generated from CT-based segmentations by assigning each organ its mean uptake from the paired PET image. Evaluation included quantitative accuracy, noise assessment, radiomic analysis, tumor segmentation performance, and a human observer study. PAD-generated images achieved high quantitative accuracy, with concordance correlation coefficients above 0.92 between organ mean SUVs and assigned activity values. The synthesized images showed noise levels and texture characteristics similar to target PET images and produced comparable tumor segmentation performance. In a two-alternative forced-choice observer study, four readers achieved approximately 50% accuracy, indicating visual indistinguishability between synthesized and target images. PAD also generated realistic PET images from XCAT-derived activity maps, demonstrating compatibility with phantom-based anatomical priors. Overall, PAD provides a diffusion-based framework for generating clinically relevant heterogeneous PET images from uniform organ activity maps derived from clinical segmentations or digital phantoms, supporting data augmentation and downstream imaging studies.
We present a Dual-Domain Equivariant Generative Adversarial Network (DDE-GAN) for multimodal CT-PET image synthesis. Traditional GAN-based approaches often operate solely in the spatial domain and ignore geometric consistency, resulting in limited structural fidelity. DDE-GAN addresses these challenges by jointly learning from both spatial and frequency (Fourier) domains, capturing complementary anatomical and spectral information. Furthermore, rotational equivariance embedded in the physics of the CT and PET measurements are integrated into the loss of both the generator and discriminator to ensure consistent responses under rotations, improving anatomical accuracy. A hierarchical dual-domain training strategy enforces intra- and inter-domain consistency through multi-stage loss functions. Evaluated on the HECKTOR 2022 CT-PET dataset, DDE-GAN achieves superior synthesis quality over baseline models for CT-PET image synthesis. The results demonstrate that combining dual-domain learning with geometric equivariance substantially enhances multimodal image synthesis accuracy and robustness, enabling practical applications in PET completion and data augmentation.
Gabriel Steele, Alzahra Altalib, Alessandro Perelli
Deep learning models in computational pathology often fail to generalize across cohorts and institutions due to domain shift. Existing approaches either fail to leverage unlabeled data from the target domain or rely on image-to-image translation, which can distort tissue structures and compromise model accuracy. In this work, we propose a semi-supervised domain adaptation (SSDA) framework that utilizes a latent diffusion model trained on unlabeled data from both the source and target domains to generate morphology-preserving and target-aware synthetic images. By conditioning the diffusion model on foundation model features, cohort identity, and tissue preparation method, we preserve tissue structure in the source domain while introducing target-domain appearance characteristics. The target-aware synthetic images, combined with real, labeled images from the source cohort, are subsequently used to train a downstream classifier, which is then tested on the target cohort. The effectiveness of the proposed SSDA framework is demonstrated on the task of lung adenocarcinoma prognostication. The proposed augmentation yielded substantially better performance on the held-out test set from the target cohort, without degrading source-cohort performance. The approach improved the weighted F1 score on the target-cohort held-out test set from 0.611 to 0.706 and the macro F1 score from 0.641 to 0.716. Our results demonstrate that target-aware diffusion-based synthetic data augmentation provides a promising and effective approach for improving domain generalization in computational pathology.
Positron Emission Tomography (PET) image reconstruction is inherently challenged by Poisson noise and physical degradation factors, which are further exacerbated in limited-angle acquisitions. While deep learning methods demonstrate promising performance, their generalization to unseen clinical data distributions remains limited without extensive retraining. We propose PET-Adapter, a test-time domain adaptation framework for generative PET reconstruction models pretrained solely on phantom data. Our method enables adaptation to clinical datasets with varying anatomies, tracers, and scanner configurations without requiring paired ground truth. PET-Adapter introduces layer-wise low-rank anatomical conditioning during adaptation and Ordered Subset Expectation Maximization-based warm-starting that initializes the generation from physics-informed reconstructions, reducing diffusion steps from 50 to 2 without compromising quality. Experiments across multiple clinical datasets demonstrate superior 3D reconstruction performance in both full-angle and limited-angle settings, highlighting the clinical feasibility and computational efficiency of the proposed approach.