Organizations: Department of Electrical and Computer Engineering, Clarkson University, Potsdam, USA · Data Science, Worcester Polytechnic Institute, Worcester, USA · Department of Computer Science, Data Science, and Artificial Intelligence, Worcester Polytechnic Institute, Worcester, USA
Abstract
Photoplethysmography (PPG) has become a ubiquitous physiological signal; however, current generative models still struggle to preserve realistic waveform morphology and learn a latent structure that captures cardiac and respiratory physiology. PPG generators trained with adversarial losses can produce plausible waveforms, but provide no inference path from a real signal to a latent representation. Variational autoencoders, on the other hand, map the PPG data to latent codes, although their decoders often blur systolic upstrokes and dampen amplitude and spectral details. Diffusion models improve waveform fidelity, but typically lack an inference path for reconstruction and physiological analysis. We propose VampPrior Latent Diffusion (VAMP-Diff), a jointly trained variational diffusion model that combines a temporal PPG encoder, a conditional one-dimensional diffusion decoder, and VampPrior regularization on a compact pooled latent. The model uses full temporal latent during diffusion reconstruction, giving the decoder access to beat timing and morphology while generating samples from learned VampPrior components instead of a fixed Gaussian prior. We demonstrate on the CapnoBase dataset that VAMP-Diff produces realistic PPG signals, reconstructs sharper physiological waveforms than Gaussian-prior baselines, preserves heart-rate information, maintains respiratory-rate consistency, and is sensitive to waveform corruptions through reconstruction error.
Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PG-LRF, a physiology-guided latent rectified flow framework. PG-LRF introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PG-LRF significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway
Publicly available phonocardiogram (PCG) datasets remain limited in size and pathological diversity, constraining both auscultation training and the generalisation of automated heart-sound classifiers. A class-conditional diffusion model for PCG generation is developed in the log-mel domain and synthetic fidelity is assessed using complementary (i) physiology-inspired plausibility metrics, (ii) downstream label-consistency evaluation, and (iii) expert listening. Experiments use the Phy-sioNet/Computing in Cardiology Challenge 2016 dataset (3240 recordings) with recording-level splits. After preprocessing and quality control, 16,749 non-overlapping 4 s clips are mapped to a normalised 1 x 128 x 128 log-mel representation to train a conditional 2D U-Net denoiser with classifier-free guidance. Signal-level plausibility is quantified on reconstructed waveforms using three lightweight metrics: an envelope-autocorrelation rhythm score, an amplitude-based explosion score, and the dominant cycle lag. Synthetic clips preserve similar dominant cycle durations but exhibit reduced envelope periodicity and increased transient burstiness relative to real clips. For downstream evaluation, a ResNet-50 classifier achieves 92.24% accuracy on the held-out real test set and 82.8% accuracy on class-balanced synthetic batches, indicating that generated signals retain discriminative structure relevant to normal/abnormal classification. In a pilot expert listening study (60 clips, two clinicians), most synthetic clips are judged as heart-sound-like, while abnormality sensitivity is low for both real and synthetic 4 s excerpts. Overall, the results provide a practical baseline for diffusion-based PCG generation while highlighting remaining challenges in retaining abnormal acoustic cues and reducing reconstruction-induced artefacts.
Accurate cardiac output (CO) estimation from photoplethysmography (PPG) is promising for unobtrusive hemodynamic monitoring, but remains difficult since CO is jointly determined by cardiac function and vascular tone. Conventional feature-based models use physiologically meaningful PPG descriptors, yet depend on accurate pulse detection and may miss latent temporal relationships. In contrast, fully end-to-end deep learning models learn directly from raw PPG but often underuse established PPG-derived prior information. Here, we introduce the Cross-View Attention Fusion Network (CVAF-Net), a prior-guided dual-view deep learning model for CO estimation from short, fixed-length PPG segments. CVAF-Net processes raw PPG as a temporal view and a feature sequence map (FSM) as a structured prior-guided view, and fuses the two representations through cross-view attention. The model was independently evaluated using 5-, 15-, and 30-s segments from three datasets: simulated pulse waves (3323 subjects), vasoconstriction provocation (79 subjects), and resting/cycling activities (10 subjects), and was compared with multiple machine learning and deep learning benchmarks. CVAF-Net outperformed most benchmark methods and achieved performance comparable to a state-of-the-art Transformer-based model, with a mean absolute error (MAE) of 0.19 L/min (MAPE: 3.95%) on simulated data and high accuracy in real-world settings (minimum MAE: 1.20 L/min). Importantly, CVAF-Net reduced FLOPs by twelvefold compared with the leading Transformer-based model. Plausibility analysis showed physiologically consistent CO estimates, with expected correlations with age (ρ=−0.274), heart rate (ρ=0.894), and systemic vascular resistance (ρ=−0.740). These findings indicate that CVAF-Net provides an accurate, computationally efficient, and generalizable approach for continuous wearable-based CO monitoring.