cs.SDJun 19, 2026

CoughPhase-CLR: Designing an acoustics-informed foundation model for coughing sound classification

Authors: Marius MoldovanAnton BatlinerThomas M. BerghausBjörn W. SchullerAndreas Triantafyllopoulos

Abstract

In this work, we introduce CoughPhase-CLR, a self-supervised learning framework designed to leverage the physiological phases of a cough for robust representation learning. Unlike generic contrastive frameworks, CoughPhase-CLR constructs positive pairs based on these specific acoustic phases. We pre-trained our model on approximately 40 hours of public cough audio and evaluated it across five downstream tasks, including COVID-19 detection, chronic obstructive pulmonary disease (COPD) state classification, and smoker status prediction. Our results demonstrate that cough-specific pre-training consistently outperforms standard random-cropping techniques when training on cough recordings. Additionally, we benchmarked a diverse set of state-of-the-art models on COPD state classification, highlighting the difficulty of this task. The best-performing models, pretrained on either general audio or respiratory sounds, achieved a UAR of 57%, failing to outperform the state-of-the-art performance of 84% UAR achieved using speech analysis.

Explore similar work

Jun 13, 2026cs.LG

Beyond Classification: A Cough Regression Benchmark for Respiratory Acoustic Foundation Models

Respiratory acoustic foundation models (FMs) excel at cough classification, yet their ability to predict continuous health quantities from cough audio remains largely unexplored, despite the clinical value of passive age, BMI, and disease probability estimation in settings where physical measurements are unavailable. We introduce the multi-model, multi-target cough regression benchmark evaluating five FMs (OPERA-CT, OPERA-CE, OPERA-GT, HeAR, M2D+Resp) across six targets on three datasets under subject-disjoint protocols, comparing linear, MLP-small, and full MLP regression heads. MLP-small beats the mean-predictor baseline on all tasks and linear probing in 23 of 30 model x task cases, with full MLP overfitting on small clinical data but recovering on larger sets, revealing a dataset size x head-capacity trade-off. HeAR leads within-dataset age regression on Coswara (9.12 yr MAE); its CIDRZ result is excluded from headline claims owing to possible HeAR-CIDRZ pretraining overlap. OPERA-GT is favored over OPERA-CT on age in all three datasets, with the CIDRZ margin within seed variance, extending a generative-pretraining advantage from breath to cough. HeAR and M2D+Resp reach near-full performance at N = 50 samples while OPERA models require N = 400. Cross-dataset transfer is strongly asymmetric as large diverse data generalises to small clinical populations (CoughVID to CIDRZ: -0.17 yr) but not vice versa (CIDRZ to Coswara: +2.43 yr, +26.6%).
Mayur Sanap, Prasanna Desikan, Edgar Lobaton
Jun 2, 2026cs.LG

CoughSense: Five-Class Respiratory Disease Classification via Whisper Encoder Fine-Tuning and Dual-Encoder Cross-Attention Fusion with Balanced Contrastive Learning

Automated cough analysis offers a path to low-cost respiratory screening, but most existing work stops at binary COVID-19 detection. A practical tool needs to tell apart several respiratory conditions from one cough recording on a consumer smartphone. We present CoughSense, a system that sorts cough recordings into five classes. These are healthy, COVID-19, asthma or respiratory condition, bronchitis, and pneumonia. We aggregated 18,301 recordings from four public datasets (Coswara, CoughVID, Virufy, and the West China Hospital Pediatric Cough Dataset) and used the OpenAI Whisper encoder as a pretrained backbone for cough disease classification. The main contribution is active-frame QKV attention pooling, which restricts attention to the first 200 of 1500 encoder tokens. This avoids the silence-dilution problem that arises because a 3-second cough fills only 150 tokens of Whisper's 30-second input window. Other training parts handle the 19 to 1 class imbalance and the four-dataset domain shift. These include WeightedRandomSampler, SpecAugment, Balanced Mixup with forced minority pairing, a supervised contrastive auxiliary loss, FiLM symptom conditioning, and gradient-reversal domain adaptation. A dual-encoder model fuses Whisper with the OPERA-CT respiratory foundation model through cross-attention. CoughSense (Whisper-tiny, 8.6M parameters) reached 82.3 percent balanced accuracy on five-fold cross-validation (macro-F1 of 0.817, AUC of 0.941). It beat an ImageNet-pretrained EfficientNet-B2 by 11.1 points and a ViT trained from scratch by 29.6 points. All five classes passed 74 percent recall and four of five passed 80 percent. The dual-encoder model reached 85.4 percent balanced accuracy. Active-frame pooling is the largest single contributor across all ablation components at 5.1 points, which should help any short-audio task using Whisper as a backbone.
Nikhil Vincent
Jun 23, 2026eess.AS

BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions

Respiratory acoustic foundation models (FMs) are benchmarked exclusively on smartphone recordings, yet clinical deployment increasingly targets body-coupled (BC) wearables whose sensors attenuate high-frequency content through tissue and bone, leaving FM reliability uncharacterised. We introduce BCoughBench, evaluating five FMs (OPERA-CT/CE/GT, HeAR, M2D+Resp) on nine classification tasks (AUROC, sensitivity at 95% specificity, Expected Calibration Error) and three age regression tasks (MAE vs. a mean-predictor baseline) across five EBEN-simulated BC sensor conditions on five labeled cough datasets. Mean AUROC declines from 0.785 (smartphone) to 0.689-0.723, degrading most under temple vibration pickup (ΔΔ = -0.096) and least under the soft in-ear (ΔΔ = -0.062). No FM meets the clinical sensitivity threshold (Se@Sp95 \geq 0.20) on most disease tasks under any BC sensor. Sex classification on the CIDRZ cohort collapses (AUROC 0.954 to 0.596-0.628, ΔΔ = -0.341) while COVID detection is nearly unaffected (ΔΔ = -0.004). Age regression is robust, improving under the forehead accelerometer on CoughVID (MAE 9.61 to 8.97 yr); HeAR leads on regression and demographic tasks, M2D+Resp on disease and characteristic tasks. BCoughBench provides a reproducible framework for FM evaluation under wearable conditions.
Mayur Sanap, Prasanna Desikan, Edgar Lobaton