eess.ASJun 19, 2026

Towards Detecting Neural Audio Codec Synthesized Heart Sounds

Authors: GirishOrchid Chetia PhukanMohd Mujtaba AkhtarBhavinkumar Vinodbhai KuwarSwarup Ranjan BeheraArun Balaji Buduru

Organizations: UPES, India · NTHU, Taiwan · VBSPU, India · IIIT-Delhi, India · Independent Researcher, India

Abstract

In this paper, we introduce Synthetic Heart Sound Detection (SHAC), a task aimed at identifying phonocardiograms (PCGs) synthesized using neural audio codecs (NACs). To facilitate research in this direction, we release CARDIOFAKE, the first benchmark dataset for SHAC containing both real and codec-synthesized PCGs. We benchmark spectral representations (MFCC, LFCC) and self-supervised learning (SSL) representations (e.g., WavLM) for the task. Furthermore, we propose GROOT, a fusion framework that integrates spectral and SSL features for leveraging their complementary behavior. Experiments show that GROOT, combining MFCC and WavLM, achieves state-of-the-art performance, outperforming individual representations and competitive baselines.

Explore similar work

Jun 1, 2026eess.SP

Diffusion-Based Heart Sound Generation: Evaluation with Physiological Signal Metrics, Classifiers, and Expert Listening

Publicly available phonocardiogram (PCG) datasets remain limited in size and pathological diversity, constraining both auscultation training and the generalisation of automated heart-sound classifiers. A class-conditional diffusion model for PCG generation is developed in the log-mel domain and synthetic fidelity is assessed using complementary (i) physiology-inspired plausibility metrics, (ii) downstream label-consistency evaluation, and (iii) expert listening. Experiments use the Phy-sioNet/Computing in Cardiology Challenge 2016 dataset (3240 recordings) with recording-level splits. After preprocessing and quality control, 16,749 non-overlapping 4 s clips are mapped to a normalised 1 x 128 x 128 log-mel representation to train a conditional 2D U-Net denoiser with classifier-free guidance. Signal-level plausibility is quantified on reconstructed waveforms using three lightweight metrics: an envelope-autocorrelation rhythm score, an amplitude-based explosion score, and the dominant cycle lag. Synthetic clips preserve similar dominant cycle durations but exhibit reduced envelope periodicity and increased transient burstiness relative to real clips. For downstream evaluation, a ResNet-50 classifier achieves 92.24% accuracy on the held-out real test set and 82.8% accuracy on class-balanced synthetic batches, indicating that generated signals retain discriminative structure relevant to normal/abnormal classification. In a pilot expert listening study (60 clips, two clinicians), most synthetic clips are judged as heart-sound-like, while abnormality sensitivity is low for both real and synthetic 4 s excerpts. Overall, the results provide a practical baseline for diffusion-based PCG generation while highlighting remaining challenges in retaining abnormal acoustic cues and reducing reconstruction-induced artefacts.
Xinqi Bao, Jia Bi, Xin Chen +2
Sep 15, 2025cs.SD

Scaling to Multimodal and Multichannel Heart Sound Classification with Synthetic and Augmented Biosignals

Cardiovascular diseases (CVDs) are the leading cause of death worldwide, accounting for approximately 17.9 million deaths each year. Early detection is critical, creating a demand for accurate and inexpensive pre-screening methods. Deep learning has recently been applied to classify abnormal heart sounds indicative of CVDs using synchronised phonocardiogram (PCG) and electrocardiogram (ECG) signals, as well as multichannel PCG (mPCG). However, state-of-the-art architectures remain underutilised due to the limited availability of synchronised and multichannel datasets. Augmented datasets and pre-trained models provide a pathway to overcome these limitations, enabling transformer-based architectures to be trained effectively. This work combines traditional signal processing with denoising diffusion models, WaveGrad and DiffWave, to create an augmented dataset to fine-tune a Wav2Vec 2.0-based classifier on multimodal and multichannel heart sound datasets. The approach achieves state-of-the-art performance. On the Computing in Cardiology (CinC) 2016 dataset of single channel PCG, accuracy, unweighted average recall (UAR), sensitivity, specificity and Matthew's correlation coefficient (MCC) reach 92.48%, 93.05%, 93.63%, 92.48%, 94.93% and 0.8283, respectively. Using the synchronised PCG and ECG signals of the training-a dataset from CinC, 93.14%, 92.21%, 94.35%, 90.10%, 95.12% and 0.8380 are achieved for accuracy, UAR, sensitivity, specificity and MCC, respectively. Using a wearable vest dataset consisting of mPCG data, the model achieves 77.13% accuracy, 74.25% UAR, 86.47% sensitivity, 62.04% specificity, and 0.5082 MCC. These results demonstrate the effectiveness of transformer-based models for CVD detection when supported by augmented datasets, highlighting their potential to advance multimodal and multichannel heart sound classification.
Milan Marocchi, Matthew Fynn, Kayapanda Mandana +1
Jun 17, 2026cs.SD

FlowFake: Liquid Networks for Audio Deepfake Detection

Audio deepfakes generated by neural text-to-speech and voice-cloning systems threaten speaker verification and public discourse at scale. The core challenge is cross-dataset generalization: detectors trained on one synthesis pipeline collapse on unseen forgeries. We argue that this failure is primarily because of structural synthetic speech artifacts which are multi-timescale trajectory anomalies. Though every existing detector aggregates a fixed-window frame statistics, this misaligns the architecture with the signal. We propose FlowFake, a Liquid Time-Constant (LTC) architecture whose hidden state evolves via a learned ODE, with per-neuron adaptive time constants simultaneously resolving spectral (10ms) and prosodic (2s) cues. At only 34K parameters FlowFake achieves formal BIBO stability and O(dt^4) integration error. On a four-dataset cross domain benchmark (ASVspoof2019-LA, FakeOrReal, InTheWild, MLAAD), FlowFake reaches 75.29% on ASVspoof2019 trained only on FakeOrReal and 79.97% trained only on MLAAD. It outperforms RawGAT-ST and Whisper-DF on every evaluated pair and matching SSL Wav2vec2 (300x larger) at 0.01% of its parameter count. The source code is available on : https://github.com/GhostRider2023/FlowFake
Shivaay Dhondiyal, Divyansh Sharma, Dinesh Kumar Vishwakarma