cs.CVJun 22, 2026

Concept Alignment Contrast and Long-Short Prompt Memory for Test-Time Adaptation of SAM3 in Medical Image Segmentation

Authors: Yubo ZhouJianghao WuPing YeShaoting ZhangGuotai Wang

Organizations: University of Electronic Science and Technology of China, Chengdu, China · Faculty of Information Technology, Monash University, Melbourne, VIC 3800, Australia · Shanghai Artificial Intelligence Laboratory, Shanghai, China

Abstract

Concept segmentation models like Segment Anything Model 3 (SAM3) show strong generalization on natural images, yet their performance degrades in medical imaging due to the domain gap caused by different imaging principles and styles. Test-Time Adaptation (TTA) is essential for improving the testing performance by updating the model on the fly without annotations. However, existing vision-language TTA methods are mainly driven by image-level uncertainty minimization, which does not necessarily reflect region-level semantic correctness in medical segmentation. Moreover, they often lack mechanisms to maintain stability in continual one-pass adaptation, leading to limited performance when reliable dense supervision is missing for segmentation. To address these issues, we propose Concept Alignment Contrast and LongShort Prompt Memory for Test-Time Adaptation (CM-TTA) of SAM3 for medical images. First, for a test sample with multiple augmentations, we introduce a novel Concept Alignment Contrast (CAC) metric, which leverages textual-visual semantic consistency to robustly evaluate prediction quality to select the best augmented view as the supervision. Second, to balance rapid and stable adaptation, we design a Long-Short Prompt Memory (LSPM) module. The short memory dynamically fuses recent prompts based on CAC scores for agile local adaptation, while the long memory maintains a stable global prompt to generate enhanced pseudo-labels. Finally, a Densely Supervised Prompt Update (DSPU) strategy is proposed to optimize the prompt embeddings with enhanced pseudo labels as dense supervision. Extensive experiments on prostate and skin lesion segmentation demonstrate that our CM-TTA framework significantly outperforms existing methods for TTA of SAM3. The code is available at https://github.com/SherlockZYB/CM-TTA.

Explore similar work

Jul 20, 2026cs.CV

Memory-Supported Synergistic Adaptation for Training-Free Test-Time Medical Image Segmentation

Test-time adaptation (TTA) aims to mitigate distribution shifts by adapting models with unlabeled target data at inference time. While TTA with vision-language models (VLMs) has shown promising results in classification, extending it to medical image segmentation remains challenging. In this setting, the adaptation gains from optimizing on VLM-generated predictions are often outweighed by the degradation to the VLM's strong pretrained features caused by noisy, update-driven learning, resulting in limited and unstable improvements. We therefore propose Memory-Supported Synergistic Adaptation (MSSA), a novel training-free TTA framework for medical image segmentation. Without updating model parameters, MSSA dynamically selects reliable image-text predictions to construct an online memory, uses them as text-guided semantic priors, and couples them with cross-image structural alignment for robust adaptation. Specifically, MSSA consists of (i) a noise-aware memory construction module that filters and stabilizes cross-modal predictions, and (ii) a relevance-driven prototype alignment module that aligns the target sample with structurally consistent memory samples and their reliable predictions to improve adaptation. Extensive experiments on multiple medical segmentation benchmarks demonstrate that MSSA consistently improves VLM-based segmentation models and outperforms existing fine-tuning-based TTA methods by a clear margin, with gains of up to 12.2% DSC and 11.7% mIoU. Project page: https://lingrayy.github.io/MSSA/ .
Lingrui Li, Nan Pu, Dong Zhao +4
Nov 24, 2025cs.CV

MedSAM3: Delving into Segment Anything with Medical Concepts

Medical image segmentation is fundamental for biomedical discovery. Existing methods lack generalizability and demand extensive, time-consuming manual annotation for new clinical application. Here, we propose MedSAM-3, a text promptable medical segmentation model for medical image and video segmentation. By fine-tuning the Segment Anything Model (SAM) 3 architecture on medical images paired with semantic conceptual labels, our MedSAM-3 enables medical Promptable Concept Segmentation (PCS), allowing precise targeting of anatomical structures via open-vocabulary text descriptions rather than solely geometric prompts. We further introduce the MedSAM-3 Agent, a framework that integrates Multimodal Large Language Models (MLLMs) to perform complex reasoning and iterative refinement in an agent-in-the-loop workflow. Comprehensive experiments across diverse medical imaging modalities, including X-ray, MRI, Ultrasound, CT, and video, demonstrate that our approach significantly outperforms existing specialist and foundation models. We will release our code and model at https://github.com/Joey-S-Liu/MedSAM3.
Anglin Liu, Xu R. Cao, Yifan Shen +4
Jun 25, 2026cs.CV

Mask to Concept: Auto-Promptable SAM3 via Efficient Test-Time Concept Embedding Search for Few-Shot Annotation

Transforming foundation segmentation models from human-prompted tools into auto-promptable annotators is critical for scalable medical data annotation. Current methods commonly depend on external feature matchers or auxiliary networks to automate geometric prompting, but introducing architectural overhead and limiting performance scalability. Although SAM3 natively supports concept segmentation via reusable text prompts, its direct use in medical imaging is hindered by a lack of fine-grained clinical knowledge and the ambiguity of human-written descriptions. In this work, we propose Mask to Concept (M2C), an efficient framework that adapts SAM3 for medical few-shot annotation without external modules, parameter retraining, or manual text engineering. Using only a few labeled images, M2C enables SAM3 to automatically search for transferable visual concepts entirely within its frozen architecture: it initializes a learnable concept embedding, uses it to prompt segmentation, and updates the embedding by gradients of minimizing the concept segmentation error. We further introduce a Hybrid Uncertainty Estimation (HUE) module that calculates the prediction entropy and maps concept predictions back to the box prompts, measuring concept-geometry prompting inconsistency. Highly uncertain samples are flagged actively for human correction, and the corrected masks are then fed back to M2C to continuously search for more precise concept embeddings, forming a self-enhancing annotation loop with minimal expert effort. Experiments on medical segmentation benchmarks show that our method achieves SOTA few-shot segmentation performance and outstanding annotation efficiency, offering a practical and efficient pathway toward scalable medical image labeling. Codes are at https://github.com/Huster-Hq/M2C.
Quan Zhou, Shaoqing Zhai, Qiang Hu +3