cs.LGJun 29, 2026

Toward an Energy-Optimized Operation of Data Centers Located in Wind Farms Using Reinforcement Learning

Authors: Jan StennerAlexander KilianSebastian PeitzHermann de Meer

Organizations: Software Innovation Campus Paderborn, Paderborn University, Germany · Chair of Computer Networks and Computer Communications, University of Passau, Germany · Lamarr Institute for Machine Learning and Artificial Intelligence, Technical University of Dortmund, Germany

Abstract

This paper studies Reinforcement Learning as an online controller for curtailment-aware workload shifting in wind-turbine-integrated high-performance computing (HPC) data centers. We introduce a reproducible fixed-day simulation framework with synthetic wind and price signals and delayed completion feedback, designed to be extensible toward more complex scenarios. As a controlled benchmarking basis, we then focus on the minimal case with one wind turbine and one co-located data center. In this setting, pure Reinforcement Learning exhibits a pronounced credit-assignment problem and tends to underuse free wind energy early in the day. We therefore evaluate two complementary countermeasures: optimization-based Imitation Learning and potential-based Reward Shaping. Across multi-seed training and a 200-day test set, Proximal Policy Optimization (PPO) and a Soft Actor-Critic (SAC) variant with an additional on-policy update routine achieve strong empirical performance among learned policies, and both Imitation Learning and Reward Shaping provide improvements in relevant configurations. A performance gap to the optimizer remains, which is expected: the optimizer plans offline with full-day foresight, whereas Reinforcement Learning must decide online from current observations without future realizations. The benchmark and ablation results provide a transparent basis for extending the approach toward richer multi-site and continuous-time scenarios.

Explore similar work

Sep 14, 2026cs.LG

Offline Reinforcement Learning for Wind Farm Control: A Wind Tunnel Study under Dynamic Wind Directions

This paper addresses the wind farm power maximization problem in the presence of wind direction changes. Specifically, a model-free Modified Twin Delayed Deep Deterministic Policy Gradient with Behavior Cloning (MTD3-BC) algorithm is proposed to tackle this task through yaw control under varying wind direction conditions. MTD3-BC is an offline reinforcement learning (RL) algorithm that aims to infer good behavior from only a precollected offline dataset. Additionally, to ensure smooth and moderate yaw adjustments, a new action consistency term is introduced into the policy optimization objective. Unlike online RL methods, MTD3-BC does not require extensive interactions with a wind farm simulator during training, significantly reducing computational costs and training time. A wind tunnel experiment is conducted to validate the effectiveness of the algorithm under varying wind directions. The results demonstrate that MTD3-BC successfully mitigates wake effects, delivering farm-level power gains of approximately 10% over the baseline greedy strategy and performance on par with a data-calibrated model-based wake-steering benchmark, while requiring no wake model and only a small fraction of the training cost of online RL. To our knowledge, this is the first time an offline RL wind farm control policy has been validated and demonstrated experimentally.
Yuhan Su, Hongyang Dong, Simone Tamaro +3
Jul 27, 2026cs.AI

Cutting AI Datacenter Energy with Reinforcement Learning: Measured Power Control of LLM Training from One GPU to the Fleet

Reinforcement-learning post-training dominates modern language-model development, yet its power behavior on GPU hardware has not been characterized, and datacenters manage GPU power with workload-blind mechanisms, static caps and reactive throttling, that slow hardware indiscriminately. We instrument GRPO training with half-second power telemetry at 7B, 14B, and 72B scales on one to four A100s (380,000+ samples), and train a PPO meta-controller that adapts the workload's own generation parameters to measured power. Against the full 500-step 7B trace, the controller cuts power-limit violations by 89.8% while increasing token output by 18.1% and energy efficiency by 26.2% (tokens per MWh). Deployed live at 72B, the same controller family yields replicated null results, diagnosed as the group-size actuator losing authority under model sharding. An actuator-authority sweep shows the same parameters applied as generation concurrency retain 17-22% power authority, isolating an occupancy-versus-volume principle; a controller rebuilt on that actuator controls a live 72B rollout-generation workload across three replications: 35.7% more output than a static safe baseline at 2.27 +/- 1.08% budget violations, 87.2% fewer violations than uncontrolled operation, and the best mean throughput and energy per token among constrained controllers, with an adaptive threshold rule matching it in one of three operating conditions. Under realistic measurement windows the original 72B transients fall from 23.6% at half-second resolution to 1.6% at 30 s and zero at 5 min; a composed 16-GPU fleet shows zero violations at 30 s and longer, with peak demand at 50-56% of nameplate. For this fleet mix, roughly twofold oversubscription of nameplate appears feasible, subject to operator validation. We quantify the economic and carbon consequences and specify a low-cost operator pilot.
Eliseo Curcio
Jul 3, 2026eess.SY

Hierarchical Multi-Agent Reinforcement Learning for Carbon-Aware AI Data Centers in Power Distribution Systems

Eco-friendly energy management for artificial intelligence data centers (AIDCs) is crucial because of the significant increase in energy consumption-induced carbon emissions from AIDCs resulting from the rapid expansion of AI applications. This paper proposes a hierarchical carbon-aware multi-agent reinforcement learning (CA-MARL) framework for robust and efficient operations of AIDCs under uncertainties while ensuring low-carbon operation of power distribution systems. The framework comprises a workload manager (WM) agent and multiple local AIDC agents trained using a multi-agent transformer method, corresponding to a global AIDC aggregator and a local AIDC operator, respectively. Leveraging AIDC operation data along with nodal carbon intensity (NCI) calculated from the carbon emission flow-integrated distribution system operator problem, the WM agent spatially allocates AI training and inference jobs among all AIDCs. Based on the jobs allocated from the WM agent and NCI information, each AIDC agent schedules economical and eco-friendly operations of the AIDC by performing the following tasks: i) temporal shifting of training jobs, ii) spatial allocation of training graphics processing unit (GPU) blocks and inference GPUs within the AIDC, and iii) control of the supply air temperature of the cooling system. The effectiveness of the proposed framework was assessed using an IEEE 33-node power distribution system.
Hyunsoo Lee, Panggah Prabawa, Dae-Hyun Choi +1