cs.ARJul 16, 2026

Toward Energy-Efficient and Low-Power Arrhythmia Detection for Wearable Devices

Authors: Floriaan BultenYawar RasheedArlene JohnVincenzo StoicoGhayoor Gillani

Abstract

Cardiovascular diseases are the leading cause of death worldwide, and conditions such as arrhythmia often require long-term monitoring for effective detection and diagnosis. However, current wearable monitoring devices are bulky, uncomfortable, and typically rely on clinicians to manually evaluate electrocardiograms (ECGs). While Deep Learning (DL) algorithms have shown superior performance in arrhythmia detection and classification, their computational complexity coupled with high power consumption limit deployment in wearable devices. To address this challenge, this paper investigates the use of approximation techniques to reduce the power and energy consumption of DL architectures while maintaining acceptable classification performance. Specifically, techniques such as data precision reduction and approximate multiplication are investigated in a state-of-the-art DL model and its corresponding hardware architecture. The model is trained and validated using the MIT-BIH Arrhythmia Database, and hardware implementations employing various approximate multipliers are synthesized and evaluated. Compared with the state-of-the-art 8.75 μW (and 2.08 μJ) reference architecture, our proposed architecture consumes 3.07 μW (and 2.17 μJ) at 12 kHz, showing 64.9% reduction in power consumption while providing an acceptable output quality, i.e., 93.7% classification accuracy and 92.1% sensitivity. At 100 MHz, our proposed architecture consumes 9.45 mW (and 0.8 μJ), showing 61.5% reduction in energy consumption as compared to the state-of-the-art architecture. These results demonstrate that our proposed approximations significantly extend wearable device battery life while preserving the required arrhythmia classification performance.

Explore similar work

Jun 13, 2026eess.SP

ECG-LDC: A Hardware-Efficient Low-Dimensional Computing Framework for ECG Arrhythmia Classification

Continuous cardiac monitoring in wearable devices demands classifiers that are simultaneously accurate, energy-efficient, and deployable on resource-constrained hardware. While deep neural network approaches have demonstrated high classification accuracy for electrocardiogram (ECG) arrhythmia detection, their substantial parameter counts and reliance on multiply-accumulate-intensive operations make them impractical for low-cost edge platforms. In this work, we propose ECG-LDC, a hardware-software co-design framework that adapts Low-Dimensional Computing (LDC) for real-time ECG arrhythmia classification. ECG-LDC employs a dual-encoder architecture with dedicated value and feature codebooks to independently encode morphological waveform features and RR-interval temporal features, enabling effective capture of both intra-beat and inter-beat cardiac dynamics. The framework encompasses data preprocessing, model training, and a hardware accelerator architecture prototyped on the Pynq-Z2 platform. Implemented using binary representations and XOR/XNOR-based operations, ECG-LDC achieves 97.18%97.18\% accuracy with a memory footprint of only 3.86 kB3.86\ \text{kB}. ECG-LDC sacrifices approximately 1.8%1.8\% accuracy versus SOTA TinyML classifiers but achieves 1111~570× 570\times reduction in memory usage; among FPGA-based five-class arrhythmia classifiers, it delivers the highest accuracy with up to 2.4×2.4\times fewer LUTs and zero DSP block utilization, affirming its suitability for real-time arrhythmia detection on resource-constrained wearable platforms.
Anh Tran, Khanh Tran, Cuong Do
Jun 1, 2026cs.LG

ArrythML: An Autoencoder-Based TinyML Approach for On-Device Arrhythmia Detection on Resource-Constrained Embedded Systems

Our work presents a method for ECG segmentation and arrhythmia detection using Tiny Machine Learning (TinyML) models for real-time, on-device inference on resource-constrained embedded systems. We develop INT8 quantized autoencoder-based TinyML models with minimal layers and parameters for embedded deployment. These models are evaluated using a custom dataset derived from the MIT-BIH Arrhythmia Database and validated in both PC-based simulations and on-device environments. For the evaluations, over 95,000 ECG segments are processed on an ESP32-S3 microcontroller running the TensorFlow Lite Micro runtime. Post-evaluation, detailed analysis, including annotation-wise and record-wise failure analysis, is conducted to characterize model behavior across diverse ECG morphologies and rhythm patterns and to explain missed detections. In several cases, apparent misclassifications may correspond to early or subtle anomaly patterns labeled as normal in the reference annotations, highlighting the model's sensitivity. A refined evaluation by filtering out ambiguous cases in the dataset shows that the best-performing DNN-based autoencoder achieves a recall of 84%, an F1-score of 79%, a model size of approximately 180 KB, and an inference latency of 9 ms on-device. These results demonstrate the feasibility of low-power, privacy-preserving embedded wearable systems capable of performing accurate arrhythmia detection entirely on-device.
Nagarajan S, Kurian Polachan
Jul 12, 2026cs.LG

LSTrans: Efficient Knowledge Transfer for Lightweight and Automated ECG Classification

Deploying deep learning models for automated electrocardiogram classification on resource-constrained wearable devices remains challenging due to high computational costs. To address this, we propose LSTrans, a lightweight hybrid model designed for efficient and sensitive ECG analysis. LSTrans introduces a specialized 1D convolutional backbone with an interleaved layer architecture to capture both macroscopic rhythmic trends and microscopic morphological variations. This backbone is cascaded with a Transformer encoder to model long-range temporal dependencies, incorporating Low-Rank Adaptation across critical layers to compress the model and reduce the trainable parameter space. We further employ homogeneous and heterogeneous knowledge distillation to transfer diagnostic expertise from high-capacity teacher models to the student. Experimental results on multiple benchmark datasets demonstrate that LSTrans achieves a competitive balance between diagnostic sensitivity and resource efficiency, substantially reducing peak memory footprints and training latency during downstream adaptation. The source code is available for review at https://github.com/zyee00128/LSTrans4BIBM.
Yi Zhao, Jiajun Gao, Chenyang Xu +2