cs.CVJul 30, 2026

Inference-Time Agentic Decision Rules Beat Longer Evolving Search for Multi-Image Medical Reasoning

Authors: Site LiJianyi HaoXiaofeng Liu

Organizations: Yale University

Abstract

Multi-image medical VQA is not merely a prompt-length problem; it is a fundamental challenge of agentic decision-making. Medical vision-language agents must aggregate evidence across ordered images, remain robust to answer-order perturbations, and avoid overfitting to noisy search-time feedback. We study MedFrameQA through a controlled comparison of five inference-time agentic strategies, optimized using the same high-budget ShinkaEvolve configuration and evaluated on a reproducible internal frozen split (1,331 evolution, 665 holdout, 855 final test). Across five independent repeated runs, the strongest method emerges as the simplest robust aggregator: the \textbf{order-vote} policy achieves 57.89±0.65%57.89 \pm 0.65\% final-test accuracy, significantly outperforming the fixed baseline (52.73±0.42%52.73 \pm 0.42\%) and the more complex, albeit brittle, order-rerank variant (55.79±0.43%55.79 \pm 0.43\%). Paired bootstrap analysis confirms these significant gains. Extending the evolutionary search budget from 50 to 100 generations yields no generalization benefit: while holdout performance marginally increases, final-test accuracy drops from 57.89%57.89\% to 56.02%56.02\%. Our findings suggest that for multi-image medical reasoning, defining the correct agentic decision rule is substantially more impactful than expanding the optimization search budget.

Explore similar work

Sep 14, 2026cs.AI

Option-Aware Retrieval and Task-Specific VLM Adaptation for Medical VQA

We describe our submission to the MedReason 2026 challenge, covering multiple-choice (MCQ) and open-ended (OE) medical visual question answering (VQA) under fully offline, containerized inference. Our first finding is that MCQ retrieval must compare answer \emph{semantics} rather than answer labels: labels are independently assigned per question, so copying a retrieved neighbor's label transfers no useful information, whereas scoring each current option's text against correct-answer text from similar training cases raises retrieval-only accuracy from 20.0% to 57.5% on a 200-case retrieval-excluded development holdout. Our second finding attributes the submitted system's accuracy: holding the task-specific MCQ Low-Rank Adaptation (LoRA) adapter fixed and varying the number kk of in-prompt retrieved examples changes accuracy by at most one case --- 187/200 (93.5%) at both k=0k=0 and the adapter's training-time k=1k=1, 188/200 (94.0%) at the packaged runtime's default k=3k=3 --- and the submitted confidence-gated override adds no net accuracy on top of k=3k=3, selecting the VLM in 198/200 cases. With the final MCQ adapter fixed, retrieval changes accuracy by at most one case, and gating provides no net gain. On 20 OE cases, token-F1 and RaTEScore~\cite{zhao2024ratescore} decrease as kk grows, but paired sign tests on token-F1 differences are nonsignificant (p0.29p \ge 0.29); a single-annotator comparison found 6/20 wrong-anchor errors for the final configuration and 14/20 for an earlier configuration that jointly differed in routing, adapter, and prompting. The system reaches 94.0% MCQ accuracy on the development holdout and 93.20% on the organizer's official pre-evaluation, versus 29.43% for the off-the-shelf reference baseline, while both of the organizer's open-ended scores are lower than that baseline's (ground-truth agreement 1.245 versus 1.588, visual accuracy 1.995 versus 2.696, each out of 4).
Tristan Kirscher, Niklas C. Koser, Soren Pirk
Jun 10, 2026cs.CV

OpenMedReason: Scientific Reasoning Supervision for Medical Vision-Language Models

High-stakes clinical use of large vision-language models (LVLMs) requires reasoning that is grounded in visual evidence and clinical knowledge, not just correct final answers. We introduce OpenMedReason, a large-scale, open multimodal medical reasoning corpus comprising approximately 450K image-question-answer instances whose reasoning traces are primarily derived from curated biomedical, human-authored scientific articles. OpenMedReason provides high-fidelity supervision beyond synthetic chains of thought, covering diverse medical domain vision modalities such as radiological scans, microscopic images, visible light photographs, charts, and others. We complement it with OpenMedReason-Bench, a held-out benchmark that allows fine-grained evaluation of LVLMs along three complementary axes of capability, including perception, medical knowledge, and rationale, enabling diagnostic evaluation beyond final-answer accuracy. OpenMedReason is a rich training resource that exhibits its effectiveness in both supervised fine-tuning (SFT) and reinforcement-based alignment. Training with OpenMedReason yields a 20% average improvement in VQA accuracy over the base model and achieves performance within 4.2% of the strongest comparable-scale medical LVLMs. Fine-grained performance analysis confirms that the gains are not concentrated in any single axis: OpenMedReason improves perception, medical knowledge, and rationale jointly, and its reasoning traces are preferred over those of the base model in 86.1% of pairwise comparisons. We release the code and dataset at huggingface.co/datasets/neginb/OpenMedReason.
Negin Baghbanzadeh, Pritam Sarkar, Michael Colacci +6
Sep 3, 2026cs.CV

MedQA-MM: Shortcuts Behind Medical Visual Reasoning

A benchmark score credits final answers, but not the route by which an item can be answered. In medical multimodal multiple-choice questions (MCQs), this distinction matters because a correct answer can be supported by the intended image finding or by benchmark-preserved cues in the wording of answers, non-visual clinical text, visible image text, artificial annotations, or device/context artifacts. We call the resulting score-level overinterpretation reasoning inflation. Here, a route is an observable input path that can support answer selection, not a claim about the model's hidden cognition. Across six medical multimodal MCQ datasets, we separate candidate cues from behavioral evidence through prompt- and image-side audits, modality ablations, and matched repairs that preserve the medical target and answer key. In a 13-configuration open-model panel, full-input accuracy is 62.63%, while text-only and options-only settings achieve 53.96% and 29.71%, respectively. Removing length-gap, absolute/conspicuous, and spatial/prepositional cues lowers accuracy by 6.58, 3.50, and 4.77 percentage points. We also construct MedQA-MM, a 1,000-item shortcut-mitigated subset, where text-only and options-only accuracy fall to 5.21% and 12.33%. This does not imply that models never use images; it shows that medical image-reasoning claims require route-level evidence.
Benlu Wang, Yifan Zhang, Jiaqing Yu +7