q-bio.NCAug 6, 2026

Transcutaneous Spinal Cord Stimulation Disrupts Conscious Ankle Proprioception and Produces a More Constrained Locomotor Pattern in Unimpaired Adults

Authors: Christopher A. JohnsonAndria J. FarrensParastoo Ali PourArjan GillanHui ZhongDavid J. ReinkensmeyerAlexandra S. Voloshina

Abstract

Transcutaneous spinal cord stimulation (tSCS) modulates spinal sensorimotor circuits primarily through activation of afferent networks. While prior work has emphasized locomotor performance and spinal excitability, how tSCS affects conscious proprioceptive perception and the extent to which such effects parallel changes in locomotor control remain unclear. We investigated the acute and training-related effects of tSCS on ankle proprioception and gait in unimpaired adults (n = 14), with an independent control group (n = 14) completing identical proprioceptive training without stimulation. Proprioception was quantified using a bilateral robotic assessment of dynamic ankle localization ability (Crisscross), gross motor output using maximum dorsiflexion strength, and gait during normal and tandem treadmill walking using spatiotemporal, trunk-sway, and mediolateral center-of-mass (CoM) excursion measures. Acute tSCS increased ankle proprioceptive error (p < 0.001) while dorsiflexion strength was unchanged (p = 0.30). Gait shifted toward a modestly more constrained locomotor pattern, characterized by reduced step width and ML CoM excursion (p < 0.05). With continued training under stimulation, proprioceptive error decreased and, unlike the control group, the tSCS group showed progressive improvement that persisted after stimulation ended. Sagittal-plane gait measures recovered toward or beyond baseline, whereas mediolateral measures remained constrained, revealing a direction-dependent reorganization of locomotor control. Together, these findings show that tSCS influences multiple aspects of the sensorimotor control loop, disrupting conscious proprioception while reshaping locomotor behavior, and that the nervous system can adapt to altered afferent input through training.

Explore similar work

May 4, 2026cs.RO

Tensegrity crutches with compliance from a pre-stressed self-tensile module improve ground reaction force profiles, speed, effort, comfort, and perceived stability

Purpose: Six million people use crutches as mobile aids in the US. Rigid designs with no axial mobility limit sensory feedback and lead to secondary injury on the upper joints. Spring-loaded designs offer compliance but may compromise stability. We designed a biologically inspired tensegrity crutch with a compliant module aiming to achieve favorable mechanical properties. The terminal module was a pre-stressed self-tensile two-cell tensegrity structure. We compared the tensegrity crutch to commercial rigid and spring-loaded crutches in mechanical tests using axial loading, in overground straight and turning walking, and in participant experience. Methods: In human trials, healthy young adults (N=18) with no recent lower-body injury performed straight walking and turning trials at a comfortable self-selected pace. A knee blocker simulated unilateral injury of the dominant leg. After using each type of crutch, participants reported their perceived levels of effort, comfort, pain, stability, and usability. Results: Compared to the rigid design, both spring-loaded and tensegrity conditions reduced peak loading rates. The tensegrity design improved effort, comfort, pain, and usability. Spring-loaded crutches reduced perceived stability and walking speed. Conclusion: The biologically inspired tensegrity crutches were an overall improvement to existing designs. Simulations and mechanical testing suggest that nonlinear stiffness, ground-following, and force feedback are among the beneficial mechanical properties that underlie this improvement.
Jingxian Gu, Joanna Spyra, Andrew Walski +3
Sep 22, 2026cs.RO

SG-CPG: Severity-Gated Central Pattern Generators for Adaptive Quadruped Locomotion under Continuous Actuator Degradation

An animal with a weakened limb does not necessarily switch its gait, instead it unloads the affected limb, re-coordinates the remaining limbs, and scales its response with injury severity. This graded adaptation allows locomotion to persist despite partial loss of limb strength, rather than requiring a discrete transition between healthy and failed. Inspired by this behavior, we propose SG-CPG, a central pattern generator (CPG) for quadruped locomotion under continuous actuator degradation. SG-CPG preserves a frozen healthy CPG policy and introduces two severity-driven gates: a residual gate that re-coordinates all four legs and an amplitude gate that progressively shortens the weakened leg's stride as degradation increases. We emulate progressive degradation through two mechanisms: lowering the joint torque ceiling (ceiling mechanism) and scaling its low-level controller gains (gain mechanism), representing distinct forms of actuator weakening. Our simulations on a Unitree Go2 show that SG-CPG maintains a trot gait with 100% survival across an omnidirectional command schedule under 95% joint strength loss while tracking commands within 8%. Under a lowered torque ceiling, removing either severity path, the residual's severity observation or the amplitude gate, raises clipping at the weakened joint from 4.4% to 13.6% and 26.3% of steps at an 80% loss. On a real Go2, SG-CPG survives 28 of 29 forward and turning trials with up to 93% calf torque degradation. These results show that severity-gated adaptation can extend a healthy locomotion policy to progressive actuator degradation without treating the fault as a discrete failure.
Adarsh Kumar Kosta, Kaushik Roy
Oct 2, 2025cs.RO

SPARC: Spine with Prismatic And Revolute Compliance for Faster Quadrupedal Bounding

Quadruped mammals coordinate sagittal spinal bending with axial extension and compression during dynamic locomotion. Yet most robotic quadrupeds use rigid trunks, passively compliant spines with fixed properties, or actively controlled spines that track prescribed trajectories. Whether actively regulated spinal compliance can support faster dynamic locomotion remains unclear. We present SPARC, a compact 1.26-kg, 3-DoF sagittal-plane spine that combines revolute and prismatic motion with independently tunable task-space stiffness and damping. A floating-base impedance controller renders the desired task-space compliance, and benchtop tests show that the fitted axial stiffness matches commanded values within 1.5%. We integrate SPARC into an 8-DoF quadruped and evaluate it across 97 bounding trials under three spine configurations: impedance-controlled SPARC, the same SPARC module held near a fixed pose using position control, and a lightweight rigid spine. Impedance-controlled SPARC reaches 1.029 m/s, compared with 0.769 m/s for position-controlled SPARC and 0.673 m/s for the rigid spine. Impedance-controlled SPARC reaches higher speeds with larger axial motion and greater mechanical power exchange, while at matched speed it has a higher electrical cost of transport than the rigid spine, revealing an energetic trade-off. Code and hardware are available at: https://github.com/YueWang996/sparc
Yue Wang, Yanran Xu