cs.CVAug 6, 2026

MirrorNet: Can Medical Image Anonymization Really Protect Patient Identity?

Authors: Attila Simkó

Organizations: Department of Diagnostics and Intervention Umeå University, Umeå, Sweden

Abstract

Medical images are routinely de-identified---names, dates, and other metadata removed---and then shared for research, teaching, and public benchmarks under the assumption that this renders them anonymous. Such de-identification protects the metadata but not the pixels, and---apart from scans that directly contain facial structures---whether the image content itself identifies the patient has received little scrutiny. We investigate this question by learning a cycle-consistent correspondence between a cross-sectional medical image and a non-medical, patient-identifying image, using a pair of coupled, cycle-consistent variational autoencoders. From a held-out scan, the model recovers a recognisable likeness of the patient (identity-region MAE = 0.163); conversely, it synthesises a scan from such an image. These results indicate that a de-identified medical scan remains identifying---it is, in effect, a photograph of the patient---and that imaging data should be governed as biometric data rather than as anonymisable records. To support reproducibility, the code and trained models are shared at https://github.com/attilasimko/public-repository.

Explore similar work

Jun 19, 2026cs.CV

Graph-of-Differences: Anatomy-Structured Difference Alignment for Medical Image Re-Identification

Medical image re-identification (MedReID) enables longitudinal patient linkage but remains vulnerable to shortcut learning and often produces decisions that clinicians cannot audit against named anatomy. We propose Graph-of-Differences (GoD), which grounds identity comparisons in explicit anatomical structure. Each image is represented as an anatomy graph whose nodes correspond to named anatomical regions; given an image pair, soft node correspondence is established, and differences are computed over matched anatomy. A graph-level difference alignment objective ties these anatomy-matched differences to the global backbone difference, ensuring the retrieval signal is anchored in homologous structures rather than arbitrary spatial tokens. Explanations are defined over named graph nodes and quantitatively audited via node insertion/deletion tests, replacing unstable pixel heatmaps with verifiable structure-level evidence. On internal benchmarks, GoD improves Rank-1 by +7.1 pp on fundus and +3.1 pp on CXR over a strong frozen-backbone baseline, with further gains on zero-shot external transfers confirming that anatomy grounding improves both accuracy and generalization. Code is available at https://github.com/GenMI-Lab/GoD.git.
Nichula Wasalathilaka, Abhijit Das, Imran Razzak +1
Aug 31, 2026cs.CV

Robust retinal biometrics for patient identity verification and retrieval across age and imaging devices

Patient identity errors can compromise longitudinal medical records, research databases, and downstream clinical decisions. We present a retinal biometric system for verifying claimed identities and retrieving the correct identity from color fundus images. We trained a 512-dimensional metric-learning encoder combining a ConvNeXtV2 backbone with ArcFace and triplet losses on 227,004 images from 21,851 patient-eye identities in the Rotterdam Study, spanning multiple imaging devices and up to 32.6 years of follow-up. The system was evaluated on held-out Rotterdam Study data and externally on the UK Biobank and Age-Related Eye Disease Study (AREDS). Before evaluation, we used the model to screen for identity inconsistencies and manually adjudicated flagged images, identifying incorrect assignments in 0.588% of Rotterdam Study images, 0.259% of UK Biobank images, and 0.164% of AREDS images. In retrospective-only verification after removing near-duplicate images, the system achieved AUROCs of 0.9998, 0.9997, and 0.9998 in the Rotterdam Study, UK Biobank, and AREDS, respectively. For identity retrieval using only previously acquired images, Recall@1 was 99.7%, 97.2%, and 97.6%, respectively, from galleries averaging 4436-8510 identities; the correct identity appeared among the top five results in at least 98.6% of cases. Performance remained robust across imaging devices and long follow-up intervals, while lower image quality and inconsistent retinal fields accounted for most failures. These findings establish retinal anatomy as a durable biometric signal, useful for safeguarding the integrity of longitudinal imaging records.
Jose D. Vargas-Quiros, Dennis Bontempi, Jeroen Vermeulen +3
Sep 9, 2026cs.CL

MedDeID enables locally governed clinical-text de-identification from real or synthetic training data

Clinical notes contain personally identifiable information (PII), restricting reuse for research and medical AI, especially when data cannot leave an institution. We developed MedDeID, an on-premises framework combining in-house annotation and synthetic-note generation with model training, inference, pseudonymisation and evaluation. On an independently annotated, adjudicated 300-note Dutch hospital benchmark, a hospital-trained compact transformer detected 98.9% of identifying text while redacting 0.24% of text outside annotated identifiers; a synthetic-only counterpart detected 96.1%. On 100 primary-care notes, the synthetic-trained model achieved higher recall than the hospital-trained model (90.3% versus 87.0%) and greater robustness to identifier-format perturbations. An English instantiation trained without real text detected 99.7% and 98.9% of annotated identifier characters on two external synthetic benchmarks. These results demonstrate transfer of the workflow to another language, but not clinical English performance. MedDeID provides a route to locally governed de-identification using real or synthetic training data.
Stig Hellemans, Tom Stroobants, Elyne Scheurwegs +3