cs.AIAug 28, 2026

Physics-Guided Flow Matching for CT Image Reconstruction

Authors: Davide Evangelista

Organizations: Department of Computer Science and Engineering University of Bologna Bologna, 40126, Italy

Abstract

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Feb 27, 2026

Efficient Flow Matching for Sparse-View CT Reconstruction

Generative models, particularly Diffusion Models (DM), have shown strong potential for Computed Tomography (CT) reconstruction serving as expressive priors for solving ill-posed inverse problems. However, diffusion-based reconstruction relies on Stochastic Differential Equations (SDEs) for forward diffusion and reverse denoising, where such stochasticity can interfere with repeated data consistency corrections in CT reconstruction. Since CT reconstruction is often time-critical in clinical and interventional scenarios, improving reconstruction efficiency is essential. In contrast, Flow Matching (FM) models sampling as a deterministic Ordinary Differential Equation (ODE), yielding smooth trajectories without stochastic noise injection. This deterministic formulation is naturally compatible with repeated data consistency operations. Furthermore, we observe that FM-predicted velocity fields exhibit strong correlations across adjacent steps. Motivated by this, we propose an FM-based CT reconstruction framework (FMCT) and an efficient variant (EFMCT) that reuses previously predicted velocity fields over consecutive steps to substantially reduce the number of Neural network Function Evaluations (NFEs), thereby improving inference efficiency. We provide theoretical analysis showing that the error introduced by velocity reuse is bounded when combined with data consistency operations. Extensive experiments demonstrate that FMCT/EFMCT achieve competitive reconstruction quality while significantly improving computational efficiency compared with diffusion-based methods. The codebase is open-sourced at https://github.com/EFMCT/EFMCT.
Aug 20, 2026

Flow Matching-Based PET Image Reconstruction

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [18F^{\text{18}}\text{F}]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.
Feb 20, 2026

DM4CT: Benchmarking Diffusion Models for Computed Tomography Reconstruction

Diffusion models have recently emerged as powerful priors for solving inverse problems. While computed tomography (CT) is theoretically a linear inverse problem, it poses many practical challenges. These include correlated noise, artifact structures, reliance on system geometry, and misaligned value ranges, which make the direct application of diffusion models more difficult than in domains like natural image generation. To systematically evaluate how diffusion models perform in this context and compare them with established reconstruction methods, we introduce DM4CT, a comprehensive benchmark for CT reconstruction. DM4CT includes datasets from both medical and industrial domains with sparse-view and noisy configurations. To explore the challenges of deploying diffusion models in practice, we additionally acquire a high-resolution CT dataset at a high-energy synchrotron facility and evaluate all methods under real experimental conditions. We benchmark ten recent diffusion-based methods alongside seven strong baselines, including model-based, unsupervised, and supervised approaches. Our analysis provides detailed insights into the behavior, strengths, and limitations of diffusion models for CT reconstruction. The real-world dataset is publicly available at zenodo.org/records/15420527, and the codebase is open-sourced at github.com/DM4CT/DM4CT.