q-bio.BMAug 28, 2026

Reconstruction-Aware Cryo-EM Particle Picking

Authors: Riku Itsuji, Yuanhao Wang, Xingjian Li, Seonghui Min, Hideo Saito, Min Xu

Organizations: Keio University, Yokohama, Japan · Keio AI Research Center, Yokohama, Japan · Carnegie Mellon University, Pittsburgh, PA, USA

Abstract

Cryo-electron microscopy (cryo-EM) determines the structures of proteins and macromolecular assemblies at near-atomic resolution, and the final 3D reconstruction depends on extracting a clean particle stack from noisy micrographs. This extraction decomposes into three sub-tasks, namely particle picking, contamination removal, and 2D class selection. Each of them, however, is trained and evaluated in isolation, and none is optimized for the reconstruction. We instead integrate the three sub-tasks into a single pipeline posed against downstream reconstruction quality. We instantiate the pipeline with a state-of-the-art component for each sub-task, CryoTransformer picking permissively, MicrographCleaner masking contamination, and CryoSift selecting 2D classes by a continuous quality score, and close the loop with a fine-tuning step that returns the surviving particles to the picker. The pipeline achieves a better 3D resolution than every picker we compare. We also show that the best 2D F1 is not the best resolution, so particle selection is better treated as one reconstruction-aware pipeline judged by the map it delivers.

Explore similar work

Apr 20, 2026cs.CV

Score-Based Matching with Target Guidance for Cryo-EM Denoising

Cryo-electron microscopy (cryo-EM) enables single-particle analysis of biological macromolecules under strict low-dose imaging conditions, but the resulting micrographs often exhibit extremely low signal-to-noise ratios and weak particle visibility. Image denoising is therefore an important preprocessing step for downstream cryo-EM analysis, including particle picking, 2D classification, and 3D reconstruction. Existing cryo-EM denoising methods are commonly trained with pixel-wise or Noise2Noise-style objectives, which can improve visual quality but do not explicitly account for structural consistency required by downstream analysis. In this work, we propose a score-based denoising framework for cryo-EM that learns the clean-data score to recover particle signals while better preserving structural information. Building on this formulation, we further introduce a target-guided variant that incorporates reference-density guidance to stabilize score learning under weak and ambiguous signal conditions. Rather than simply amplifying particle-like responses, our framework better suppresses structured low-frequency background, which improves particle--background separability for downstream analysis. Experiments on multiple cryo-EM datasets show that our score-based methods consistently improve downstream particle picking and produce more structure-consistent 3D reconstructions. Experiments on multiple cryo-EM datasets show that our methods improve downstream particle picking and produce more structure-consistent reconstructions.
Sep 8, 2026cs.CV

FPicker: Topology-Guided Evolution for Filament Tracing in Low-SNR Microscopy

Automating filament tracing in Cryo-Electron Microscopy (Cryo-EM) is essential for 3D helical reconstruction but challenged by intersecting topologies and extremely low Signal-to-Noise Ratios (SNR=σs2/σn2\text{SNR} = σ_s^2/σ_n^2 < 0.1 or -10 dB). Existing paradigms fail: pixel-wise segmenters suffer from severe topological fracturing, box-based detectors face ghost center drift, sequential trackers derail due to error accumulation, and traditional active contours collapse under artificial closed-curve constraints. To resolve these bottlenecks, we present FPicker, the first topology-guided framework reconciling these incompatibilities. It unifies perception via a center-endpoint representation and an open-curve evolution module to explicitly model non-cyclic connectivity. On simulated benchmarks, FPicker outperforms top baselines by over 40%40\% relative gain in mean spatio-angular precision (mSAP) and reduces topological gap rates by over 60%60\% under extreme noise (−20 dB-20\text{ dB}). By learning intrinsic physical geometry rather than local texture, FPicker demonstrates strong potential as a resilient geometric backbone. Its zero-shot performance on the real-world EMPIAR dataset exhibits robust topological resistance, achieving a state-of-the-art 82.9% mSAP upon fine-tuning. Our results also suggest modeling physical priors is a highly robust path toward bridging the sim-to-real gap in signal-starved scientific imaging. The code is publicly available at: https://github.com/tomzhaosky/FPicker.
Oct 1, 2026q-bio.BM

Fold'EM: Direct atomic structure inference from Cryo-EM particles

Single-particle cryo-electron microscopy (cryo-EM) has become a widely adopted technique for biomolecular structure determination. The conventional cryo-EM computational pipeline first combines many particle images to reconstruct an electrostatic potential (ESP) map and then fits an atomic model to the recovered map. Density reconstruction has high sample complexity, requiring large numbers of particle images and making structure determination high-cost and low-throughput, particularly for heterogeneous samples. Downstream atomic model building, in turn, becomes increasingly difficult as the resolution of the reconstructed map deteriorates. Protein structure prediction models provide strong sequence-derived priors on atomic structure, and experiment-guided approaches can use these priors to recover structures consistent with experimental measurements. Yet, in cryo-EM, such priors are typically integrated only after density reconstruction during atomic model fitting. We introduce Fold'EM, an inference-time framework that combines priors from protein generative models directly with cryo-EM particle images to determine atomic models from a small number of single particle images, bypassing both intermediate density reconstruction and downstream model building against the reconstructed map. Across synthetic and experimental cryo-EM datasets, Fold'EM recovers accurate atomic structures both with known particle orientations and in an ab-initio setting where orientations are inferred jointly with structure. In heterogeneous datasets, Fold'EM further resolves distinct conformational states from mixed particle populations without separately reconstructing a density map and building an atomic model for each state. We believe these results open new avenues for structure determination in the low-sample regime and for characterizing low-population conformational states directly from cryo-EM particles.