Detector response nonuniformity introduces systematic projection errors and ring artifacts in photon-counting detector computed tomography (PCD-CT). In measured PCD-CT data, residual stripe amplitudes vary slowly with projection angle, which fixed-bias models cannot adequately capture. We propose TRACE, a two-stage unsupervised sinogram decomposition method for estimating and correcting these response-related errors. TRACE represents stripes as a fixed bias plus low-order discrete cosine transform (DCT) components, using a small number of coefficients to describe angular variations at each detector element. A learnable analysis--synthesis architecture represents the ideal projections, while two-stage optimization separates them from fixed and then dynamic stripes. An angular-gradient soft orthogonality constraint suppresses correlated variations within the shared DCT gradient subspace, reducing the leakage of object structures into the artifact estimate. All parameters are optimized directly on the measured sinogram without paired training data. Experiments on measured QRM mouse phantom and porcine trotter data show that TRACE suppresses ring artifacts and improves image uniformity while preserving edge sharpness, soft-tissue texture, and trabecular detail.
The goal of this work is to reduce the effect of photon noise in dental cone-beam CT reconstruction. We consider an inverse problem formulation and develop a databased prior. To this end, we simulate fan-beam acquisitions and add photon noise to the projection data. The prior is obtained by training a gradient-step denoiser using reconstructed simulated acquisitions. The trained model is integrated into a plug-and-play gradient-step algorithm to reconstruct images from simulated projections. Experiments on synthetic data demonstrate the denoising capabilities of the trained model, while qualitative evaluations on real images showcase the algorithm's performance and generalization ability.
Idris Tatachak, Luis Kabongo, Nicolas Papadakis +2
Cone-beam computed tomography (CBCT) frequently suffers from data truncation, which introduces severe artifacts and limits the effective field of view (FOV). Existing deep learning methods for truncated cone-beam computed tomography (CBCT) reconstruction suffer from serious limitations, including a strict reliance on supervised ground truth and a failure to account for continuous 3D spatial truncation variations. To address these challenges, we introduce a self-supervised 3D reconstruction framework based on neural scene representations. By directly mapping spatial coordinates to radiodensity under projection supervision, our approach inherently bypasses traditional filtering and backprojection operations, thereby fundamentally eliminating truncation-induced ring artifacts while enabling robust continuous 3D data extrapolation. However, coordinate networks are susceptible to an inherent spectral bias, which leads to a severe loss of clinically vital high-frequency textures. To resolve this bottleneck, we further incorporate a physics-based iterative refinement module into the neural scene representation architecture. Leveraging the artifact-free, extrapolated volume from the coordinate network as an optimal initialization, this module progressively re-extracts and injects high-frequency structural information from the original projections back into the volume. Extensive experiments on both simulated and real-world datasets demonstrate that our method successfully unifies the exceptional artifact suppression and extrapolation capabilities of neural networks with the high-fidelity detail preservation of iterative algorithms.
Computed tomography (CT)-based attenuation and scatter correction improves quantitative PET but adds radiation exposure that is particularly undesirable in pediatric imaging. Existing CT-free methods are commonly trained in homogeneous settings and often degrade under scanner or radiotracer shifts, which limits their clinical utility. We propose the Generalizable PET Correction Network (GPCN), a dual-domain network for domain-robust CT-free PET attenuation and scatter correction. GPCN combines a multi-band contextual refinement module, which models pediatric anatomical variability through wavelet-based multiscale decomposition and long-range spatial context modeling, with a frequency-aware spectral decoupling module, which performs coordinate-conditioned amplitude/phase refinement in the Fourier domain. By synergizing multi-band spatial contextual modeling with asymmetric frequency-spectrum decoupling, the network explicitly separates invariant topological structures from domain-specific noise, thereby achieving precise quantitative recovery of both anatomical organs and focal lesions. This design aims to separate anatomy-dominant structures from domain-sensitive spectral residuals and to improve robustness across heterogeneous imaging conditions. We train and evaluate the method on 1085 pediatric whole-body PET scans acquired with two scanners and five radiotracers. In both joint training and zero-shot cross-domain evaluation, GPCN outperforms representative baselines and maintains stable quantitative accuracy on unseen scanner-tracer combinations. The method is further supported by ablation, region-wise quantitative analysis, and downstream segmentation experiments. In our cohort, the CT component of the conventional protocol corresponded to an average effective dose of 10.8 mSv, indicating the potential clinical value of reliable CT-free correction for pediatric PET.