cs.LGSep 23, 2026

Learning Where to Look: A Shared Relative-Alignment Module for Time-Series Forecasting and PPG-to-Vital-Sign Reconstruction

Authors: Ragamayi Puli, Shunya Nagashima

Abstract

PPG-to-vital-sign reconstruction turns a wrist-worn photoplethysmogram into clinical waveforms such as the ECG. Long-horizon multivariate time-series forecasting underpins planning in energy, weather, and traffic. Both generate a target sequence from a condition sequence, and current models hard-code where each target position reads it, as a same-position copy or seasonal recurrence, so neither transfers between tasks. We propose ROOSTER, one conditioning module that handles vital-sign reconstruction and time-series forecasting alike by learning this correspondence. Its core is a periodic-comb bias over the target-condition offset whose center, period, and sharpness are learned per head, so one module settles on the identity alignment or a seasonal lag and reports which it found. On vital-sign reconstruction from PPG, ROOSTER outperformed the published baselines on four heart-rate and respiratory-rate benchmarks. On multivariate time-series forecasting, it achieved the best horizon-averaged MSE on four benchmarks and outperformed the forecasting model it extends on 20 of 24 dataset-horizon settings under matched three-seed training. An ablation study indicated that the relative bias, not content matching, carried the alignment.

Explore similar work

Jun 13, 2026eess.SP

CAP: Towards PPG Universal Representation Learning with Patient-level Supervision

Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support. Yet existing approaches to universal PPG representation learning largely focus on signal-level objectives and often overlook patient-level health context, which limits generalization to complex clinical tasks and heterogeneous cohorts. To address this gap, we construct a large-scale paired PPG-EHR multimodal dataset by distilling fragmented medical histories and clinical records into cohesive, patient-level electronic health records (EHR). Building on this resource, we propose Clinical Anchored Pretraining for PPG (CAP). During pretraining, CAP performs cross-modal contrastive alignment that anchors PPG representations to patient-level clinical semantics, guiding the encoder beyond waveform fitting toward modeling consistency in a patient's overall physiological state. During downstream adaptation, the pretrained PPG encoder provides clinically grounded representations that strengthen inductive bias and improve robustness and transferability. Experiments demonstrate that CAP consistently outperforms strong baselines on four diverse downstream tasks. CAP achieves a particularly large gain on respiratory rate prediction (up to +87.6% relative improvement over the state-of-the-art baseline) and delivers an average relative +26.7% across all tasks. We further enhance the interpretability of our approach through comprehensive analyses, including ablations and multiple complementary visualizations of the learned representations. The code for our experiments is available at: https://github.com/gody123gody/CAP .
Chenyang He, Xinyi Shao, Shun Huang +4
May 1, 2026cs.LG

Physiology-Aware Masked Cross-Modal Reconstruction for Biosignal Representation Learning

Biosignals acquired from different locations on the body often provide temporally ordered views of the same underlying physiological process. However, most existing self supervised learning methods treat these signals as interchangeable views, overlooking the directional temporal dynamics that link them. A canonical example is the relationship between electrocardiography (ECG), which captures the electrical activation initiating each heartbeat, and photoplethysmography (PPG), which records the resulting peripheral pulse delayed by vascular dynamics. To capture this structured relationship, we introduce xMAE, a biosignal pretraining framework that leverages masked cross modal reconstruction across temporally ordered biosignals as a training time constraint to encourage physiologically meaningful timing structure in the learned representations. We show that pretraining with xMAE yields representations that outperform both unimodal and multimodal baselines on 15 of 19 downstream tasks, including cardiovascular outcome prediction, abnormal laboratory test detection, sleep staging, and demographic inference, while generalizing across devices, body locations, and acquisition settings. Further analysis suggests that the ECG PPG timing structure is reflected in the learned PPG representations. More broadly, xMAE demonstrates the effectiveness of incorporating temporal structure into multimodal pretraining when signals observe different stages of a shared underlying process. Code is available at https://github.com/hzhou3/xMAE.
Hao Zhou, Simon A. Lee, Cyrus Tanade +12
Jul 22, 2026cs.LG

Zero-Shot Heart Rate Variability Forecasting from Consumer Wearables Using Time Series Foundation Models

Short-term Heart Rate Variability (HRV) forecasting could provide clinicians with actionable lead time for detecting autonomic dysfunction and adverse cardiac events. Consumer wearable devices generate fragmented, artifact-rich HRV signals that challenge conventional forecasting approaches. In this study, we evaluated the forecasting ability of three Time Series Foundation Models (TSFMs), TimesFM, Chronos, and MOIRAI, against traditional baselines (Mean, Exponential Smoothing, and Exponentially Weighted Moving Average) on real-world wearable data collected from 49 healthy individuals. To address data fragmentation, we introduce a variability-preserving imputation method that augments linear interpolation with locally adaptive stochastic noise, retaining physiological dynamics essential for accurate forecasting. The results show that TSFMs outperformed all baselines without fine-tuning, achieving average Mean Absolute Scaled Error (MASE) between 0.81 and 0.87 across TSFMs and both context lengths (32 and 64 time steps), with Chronos and TimesFM as the top models, though MOIRAI showed limited gains over baselines. With up to a 2-hour forecast horizon, the results establish a baseline for TSFMs' performance on a real-world dataset, highlighting domain-specific fine-tuning as a promising direction for clinical deployment.
Luukas Peräkylä, Fahad Sohrab, Ville Hautamäki +3