physics.opticsSep 27, 2026

Multi-Aperture PPG with MAPIS: Spatial Optical and Temporal Coherence Fields

Authors: Shuguang Wang, Yuanjing Wang

Abstract

Conventional reflectance photoplethysmography (PPG) typically reduces tissue optical responses to one or a few detector channels. Matrix Pinhole Image Sensing (MAPIS) instead simultaneously samples multiple aperture-dependent optical signals. We analyzed 44 recordings of 30 seconds each from a single MAPIS device to characterize the spatial relationships among DC intensity, pulsatile AC, perfusion index (PI), and temporal coherence across Red and infrared channels. AC increased sublinearly with DC at both wavelengths, resulting in higher PI toward lower-DC apertures, consistent with a first-order relative path-sensitivity interpretation. A second counterintuitive spatial trend was observed in temporal coherence: lower-DC and lower-AC apertures exhibited higher autocorrelation and greater cardiac-periodic spectral concentration. IR signals also showed consistently higher temporal coherence than corresponding Red signals. These observations demonstrate that multi-aperture PPG resolves reproducible spatial relationships among optical intensity, fractional pulsatile sensitivity, and waveform coherence that are largely averaged together in conventional single-channel PPG. The present study establishes within-device relationships and motivates controlled studies of the underlying photon-path mechanisms.

Figures & tables

Explore similar work

Jun 2, 2026cs.CV

Spatial Artifact Coherence Determines Codec Robustness in Patch-Based rPPG

Remote photoplethysmography (rPPG) achieves low heart-rate error on uncompressed benchmarks yet is deployed over compressed video channels in telehealth, neonatal ICU, and driver fatigue applications. No prior work identifies the physical quantity determining when spatial decomposition outperforms global-projection methods under codec compression. We propose Spatial Artifact Coherence (SAC), defined as the ratio of off-diagonal to diagonal energy in the 4x4 inter-patch Green-channel covariance matrix (bandpass 0.75-2.5 Hz), and the PatchPCA algorithm family (four codec-aware rPPG algorithms). We evaluate 280 subjects across three public datasets, 11 codec degradation variants (MPEG-4, H.265, H.264, JPEG, chroma subsampling), and 13 algorithms via Wilcoxon tests (BH-FDR, q < 0.05, 904 tests). SAC explains 93.8% of between-variant variance in PCA advantage (r = +0.969), with zero overlap between codec families: non-MPEG-4 variants cluster at SAC 0.10-0.18 with 84-90% PCA win rates, while MPEG-4 variants cluster at SAC 0.48-0.59 with 61% win rate and a 5.8x reduction in mean improvement. Within subjects, 78% confirm the expected pattern (p < 10^-22, dz = 0.73). Within-variant subject-level SAC correlation is r = +0.099, confirming SAC classifies codec families rather than predicting individual outcomes. MPEG-4's effect is structural (macroblock DCT geometry, not noise amplitude), governed by source codec state, not resolution. P-Hybrid is identified as the most deployment-robust algorithm. Two necessary operating conditions for PatchPCA advantage are established: SAC < 0.30 and low-to-moderate motion, directly ruling out raw-to-MPEG-4 transcoding pipelines. SAC provides a physically grounded metric for codec-aware rPPG algorithm selection in clinical remote monitoring systems.
May 21, 2026eess.IV

Time-varying rPPG signal separation via block-sparse signal model

Remote photoplethysmography (rPPG) enables non-contact measurement of cardiac pulse signals by analyzing subtle color changes in facial videos. Nevertheless, extracting rPPG signals remains challenging because of their extremely weak signal strength and susceptibility to illumination noise. In this paper, we propose an rPPG signal extraction method that exploits the quasi-periodic characteristics of rPPG signals. Our approach models quasi-periodicity of the rPPG signal, which arises from the stable cardiac cycle, as a block-sparse structure in the time-frequency domain. To incorporate a block-sparse model and enable adaptive signal separation under illumination fluctuations, we construct a time-varying signal separation framework. Experiments using a public dataset demonstrate the effectiveness of our method.
May 19, 2026physics.med-ph

Cross-View Attention Fusion Net: A Prior-Guided Dual-View Representation Learning for Cardiac Output Estimation from Short-Term PPG Signals

Accurate cardiac output (CO) estimation from photoplethysmography (PPG) is promising for unobtrusive hemodynamic monitoring, but remains difficult since CO is jointly determined by cardiac function and vascular tone. Conventional feature-based models use physiologically meaningful PPG descriptors, yet depend on accurate pulse detection and may miss latent temporal relationships. In contrast, fully end-to-end deep learning models learn directly from raw PPG but often underuse established PPG-derived prior information. Here, we introduce the Cross-View Attention Fusion Network (CVAF-Net), a prior-guided dual-view deep learning model for CO estimation from short, fixed-length PPG segments. CVAF-Net processes raw PPG as a temporal view and a feature sequence map (FSM) as a structured prior-guided view, and fuses the two representations through cross-view attention. The model was independently evaluated using 5-, 15-, and 30-s segments from three datasets: simulated pulse waves (3323 subjects), vasoconstriction provocation (79 subjects), and resting/cycling activities (10 subjects), and was compared with multiple machine learning and deep learning benchmarks. CVAF-Net outperformed most benchmark methods and achieved performance comparable to a state-of-the-art Transformer-based model, with a mean absolute error (MAE) of 0.19 L/min (MAPE: 3.95%) on simulated data and high accuracy in real-world settings (minimum MAE: 1.20 L/min). Importantly, CVAF-Net reduced FLOPs by twelvefold compared with the leading Transformer-based model. Plausibility analysis showed physiologically consistent CO estimates, with expected correlations with age (ρ=−0.274ρ= -0.274), heart rate (ρ=0.894ρ= 0.894), and systemic vascular resistance (ρ=−0.740ρ= -0.740). These findings indicate that CVAF-Net provides an accurate, computationally efficient, and generalizable approach for continuous wearable-based CO monitoring.