cs.CVOct 1, 2026

CineMR: Tool-Integrated Vision-Language Reasoning for Quantitative Cardiac MRI Assessment

Authors: Kunyang Li, Hai Nguyen, Joshua Lowe, Chenguang Zhao, Peace C. Madueme, Mehdi Hedjazi Moghari, Mubarak Shah, Pegah Khosravi, +1 more

Organizations: Institute for Artificial Intelligence, University of Central Florida · Department of Clinical Sciences, College of Medicine, University of Central Florida · Nemours Cardiac Center, Nemours Children’s Hospital, Florida · Children’s Heart Center, WVU Golisano Children’s, West Virginia

Abstract

Cardiovascular magnetic resonance (CMR), including cine imaging, is a reference standard for the noninvasive assessment of cardiac morphology and ventricular function. Cine CMR interpretation integrates qualitative visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion. Current medical vision-language models (VLMs) cannot reliably derive quantitative measurements from multidimensional cine images without analysis tools. We present CineMR, a tool-augmented VLM that invokes cardiac image-analysis tools and integrates their outputs into interleaved reasoning for quantitative CMR assessment. We also construct a multi-cohort visual question answering benchmark covering quantitative metric extraction, multiclass diagnosis, and differential diagnosis, together with tools for segmentation, phase selection, volumetry, morphometry, and regional wall motion analysis. CineMR is trained with supervised fine-tuning (SFT) on tool-interaction traces followed by Group Relative Policy Optimization (GRPO) with conditional tool-use rewards. On the multi-cohort cine CMR benchmark, CineMR achieves 35.9% pass@1 and 58.9% pass@4, compared with 1.5% pass@1 for the Qwen3-VL-8B backbone and 0.0% and 7.0% pass@1 for LLaVA-Med v1.5 and MedGemma-4B, respectively. Correct tool invocation reaches 99.8% after GRPO, up from 78.9% after SFT. Live tool outputs improve ventricular measurement accuracy by 20.4--23.7% over direct model predictions, and removing all tools reduces pass@1 from 35.9% to 27.9%. These results highlight the importance of reliable tool use for quantitative cine CMR reasoning and support CineMR as a promising approach for assistive cardiac image assessment. Code, benchmark resources, and model weights are available at https://github.com/AI-MIND-Lab/CineMR.

Figures & tables

Appendix figures & tables2 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 30, 2026cs.CV

Learning Where to Look: Anatomical Grounding and Guided Attention for Cardiac MRI Vision-Language Models

Cardiac magnetic resonance imaging (CMR) enables assessment of cardiac anatomy, ventricular function, and myocardial tissue characteristics. Clinicians interpret these images by identifying cardiac structures and focusing on the regions relevant to each clinical question, motivating anatomically guided vision-language models (VLMs). Yet CMR-specific supervision for anatomical localisation and clinical question answering remains limited. To address this gap, we investigate fine-grained CMR visual question answering through anatomical grounding and guided attention. We construct 128,915 anatomical-grounding and 42,799 clinical QA pairs across short-axis cine, late gadolinium enhancement, and long-axis cine. These datasets support anatomical recognition, localisation, and clinical assessment without requiring paired reports for individual training images. To help the model learn where to look, we introduce Cardiac Anatomy-Routed Attention (CARA), which selects predicted anatomical priors according to the question and guides decoder attention with learned task-specific strengths. Combining anatomical grounding pretraining with CARA yields our model, CARA-VL. Experiments demonstrate CARA-VL's strengths in clinical assessment and regional localisation across CMR imaging settings, with promising generalization to an external clinical cohort. Together, our data and method provide a practical framework for studying and advancing cardiac visual understanding in VLMs. We will release the QA data derived from public datasets upon publication.
May 28, 2026cs.CV

CardioLens: Revealing the Clinical Reality Gap of MLLMs via Multi-Sequence Cardiac MRI Evaluations

Multimodal Large Language Models (MLLMs) have shown strong performance on public medical benchmarks, yet existing evaluations often remain weak proxies for clinical use, relying on isolated inputs and simplified recognition-style tasks. We introduce CardioLens, a leakage-resistant evaluation testbed for multi-sequence Cardiovascular Magnetic Resonance (CMR), constructed from private hospital archives through a rigorous report-to-QA construction and verification pipeline. CardioLens contains 473,896 slices and 13,494 verified QA pairs across 4D Cine, LGE, perfusion, and T2-weighted imaging, and evaluates three stages of CMR interpretation: image understanding, report generation, and disease diagnosis. Across 24 state-of-the-art MLLMs, CardioLens reveals a substantial clinical reality gap: models perform poorly overall, with performance degrading along the real CMR workflow. Confusion analysis further shows a category-collapse failure mode, where models default to frequent abnormal categories rather than distinguishing clinically distinct findings. To rule out MLLM-compatible input construction as the primary cause, we compare random, clinically motivated, and data-driven slice selection protocols under different slice budgets; performance changes only marginally, typically by about 1%. Explicit reasoning prompts also fail to rescue performance, often making models more conservative rather than improving visual evidence use. These results show that current MLLMs remain far from reliable CMR interpretation, where clinical decisions require integrating distributed evidence across sequences, views, and temporal phases. CardioLens provides a clinically grounded testbed for developing next-generation MLLMs toward real-world clinical deployment.
Sep 1, 2026cs.CV

CMRVision: A Foundation Model for Cardiac MR Image Analysis

Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.