Deep Learning for Sleep Heart Rate Estimation from Accelerometers: Toward Population-Scale Cardiac Insight Without Optical Sensors
Authors: Tanbin Islam Rohan, Pranjol Sen Gupta, Tanusree Debi, Nazmus Sakib
Organizations: Department of Information Technology Kennesaw State University Kennesaw, GA, USA · School of Computing University of Georgia Athens, GA, USA
Large longitudinal cohorts often contain wrist accelerometry without optical heart-rate sensing, motivating recovery of cardiac information from motion signals already collected during sleep. We present SeqSmoother, a transformer-based temporal corrector for sleep heart rate (HR) estimation from wrist accelerometry. SeqSmoother combines spectral descriptors with an intermediate Nightbeat-derived frequency anchor and a physics-motivated sub-harmonic feature designed to identify harmonic frequency lock-on. All inference-time features are derived from wrist accelerometry, while ECG is used only to construct reference HR labels and training-label quality weights. We evaluate SeqSmoother using 13 participant-disjoint held-out folds and compare it with the official Nightbeat implementation under a matched 60-s window and 15-s step protocol. Across all out-of-fold predictions, SeqSmoother achieved a participant-macro MAE of 1.60 bpm. On Nightbeat-retained matched intervals, Nightbeat achieved lower absolute error than SeqSmoother (0.615 versus 1.091 bpm), while SeqSmoother provided estimates over a larger portion of the eligible recording; Nightbeat produced final estimates for 72.85% of the SeqSmoother-eligible out-of-fold grid. Separately, the proposed sub-harmonic ratio achieved an AUROC of 0.972 for identifying reference-defined harmonic lock-on candidates. These findings reveal an accuracy-availability trade-off between learned temporal modeling and quality-gated signal processing while providing empirical support for a physics-informed approach to identifying frequency-tracking failures in accelerometer-based sleep HR estimation.
Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics. Existing signal-processing methods degrade under strong motion, while unconstrained deep learning approaches often lack physiological interpretability and identifiable structure. We propose a Physically-Constrained Harmonic Separation (PCHS) framework that formulates HR and RR estimation from wrist PPG as an analysis-by-synthesis problem, where accelerometer measurements condition artifact separation rather than directly regressing vital signs. A physics-guided harmonic generator decomposes the observed signal into quasi-periodic physiological components and a motion-related residual, enabling HR recovery from the fundamental frequency and RR prediction from respiratory-driven modulations of the harmonic parameters. Robust reconstruction objectives, separation constraints, and uncertainty-aware weighting stabilize the decomposition under motion. Experiments on the motion-intensive PPG-DaLiA dataset demonstrate that PCHS outperforms state-of-the-art methods while yielding interpretable signal decompositions that effectively disentangle physiological activity from motion artifacts.
1TICLab, International University of Rabat, Morocco · College of Computing, Mohammed VI Polytechnic University, Morocco · Faculty of Engineering, University of Leeds, UK
Short-term Heart Rate Variability (HRV) forecasting could provide clinicians with actionable lead time for detecting autonomic dysfunction and adverse cardiac events. Consumer wearable devices generate fragmented, artifact-rich HRV signals that challenge conventional forecasting approaches. In this study, we evaluated the forecasting ability of three Time Series Foundation Models (TSFMs), TimesFM, Chronos, and MOIRAI, against traditional baselines (Mean, Exponential Smoothing, and Exponentially Weighted Moving Average) on real-world wearable data collected from 49 healthy individuals. To address data fragmentation, we introduce a variability-preserving imputation method that augments linear interpolation with locally adaptive stochastic noise, retaining physiological dynamics essential for accurate forecasting. The results show that TSFMs outperformed all baselines without fine-tuning, achieving average Mean Absolute Scaled Error (MASE) between 0.81 and 0.87 across TSFMs and both context lengths (32 and 64 time steps), with Chronos and TimesFM as the top models, though MOIRAI showed limited gains over baselines. With up to a 2-hour forecast horizon, the results establish a baseline for TSFMs' performance on a real-world dataset, highlighting domain-specific fine-tuning as a promising direction for clinical deployment.
Luukas Peräkylä, Fahad Sohrab, Ville Hautamäki +3
Tampere University, Tampere, Finland · University of Eastern Finland, Finland
Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments. Remote photoplethysmography (rPPG) enables non-contact heart-rate (HR) estimation from an RGB camera, making it a promising sensing modality for robot-mounted vision systems. However, illumination variation remains a major barrier to robust deployment. This paper presents an end-to-end spatial-temporal transformer framework for remote HR estimation on a new dataset with varied illumination. Our estimator integrates PRNet-based 3D face alignment, clip-level illumination augmentation, the Residual Temporal Standardization Module, and controlled hybrid temporal-frequency supervision. The training objective combines a Soft-Shifted Pearson waveform loss with a spectral Kullback-Leibler divergence loss, where a tuned weight (β) controls the contribution of frequency-domain heart-rate guidance. Experiments on a static all-level mix protocol covering three illumination levels show that β=5 provides the strongest result among the tested beta settings, achieving a best-run HR mean absolute error (MAE) of 0.79 bpm and an HR correlation of 0.982. Compared with the PhysFormer baseline evaluated on our dataset, our estimator reduces HR MAE by 93.6 %, while increasing HR correlation from 0.088 to 0.982, making it usable when illumination varies.
Zhi Wei Xu, Torbjörn E. M. Nordling
Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan.