cs.ROOct 8, 2026

FallGown: A Soft Pneumatic Wearable Device for Fall Prevention

Authors: Megan C. Coram, Haoran Lei, Steven H. Collins, Steve B. Cousins, Michelle Baldonado, Cynthia Sung, Allison M. Okamura

Organizations: Department of Mechanical Engineering and Robotics Center, Stanford University, Stanford, CA, 94305, USA · General Robotics, Automation, Sensing & Perception (GRASP) Lab, University of Pennsylvania, Philadelphia, PA 19104, USA

Abstract

Concerns about falling and potential resulting injuries prevent many older adults from participating in forms of health-improving exercise such as walking, dance, and tai chi. Existing passive devices like walkers require use of the arms for support, and active devices like exoskeletons and robotic frames are often rigid, bulky, and stigmatized, which limits their use. The FallGown is a soft wearable support structure consisting of pressurized pneumatic pouches within a fabric shell; it can support the full weight of a user's body and aims to prevent falls. It is portable (6.9 kg and 0.051 m3 when stored), minimally burdensome (7.24-20.8 N drag force depending on floor type and whether an optional rolling base frame is used), and convenient (less than 2.5 minutes on average to don and less than 0.5 minutes on average to doff). The optional rolling base lowers friction with the floor, but reduces portability and skirt deformation (which can be useful to fit through doors and other tight spaces). Fall prevention testing with a single user revealed a tradeoff between device size and stability against tipping; a skirt with 12 pneumatic pouches and a floor diameter of 1.4 meters with a base frame prevented all falls except in one case with a mechanical failure. On-board pressure sensors can sense the user's weight distribution, providing an opportunity for monitored exercise and adaptive support.

Figures & tables

Explore similar work

Jun 1, 2026

Improved Postural Stability Using a Lightweight Semi-Active Soft Back Support Device Under Standing Perturbations

Older adults are particularly susceptible to falls following perturbations during standing, such as forward loss of balance. Back support devices that assist trunk extension may help mitigate fall risk by preventing excessive trunk flexion. Previous studies have investigated heavy back support devices; however, these systems often introduced adverse effects on stability due to their added mass, which shifted the body's natural center of mass unfavorably. In contrast, lightweight passive devices have shown limited benefits, as they can generate only modest assistive forces during the relatively small trunk flexion associated with forward balance loss. In this study, we evaluated the effects of a lightweight semi-active soft back support device on postural stability following standing perturbations. Our device combines an active element (a pneumatic artificial muscle) in parallel with a passive elastic band. The active element rapidly provides assistive force following a perturbation, overcoming the limitations of passive devices. Experiments conducted with five healthy individuals demonstrated that the semi-active device significantly reduced whole-body angular momentum and increased the margin of stability, indicating improved balance recovery performance. These results highlight the promise of semi-active soft wearable robots as an effective and lightweight strategy for fall prevention during standing perturbations.
Jun 1, 2026

Impact of a Soft Wearable Back-Support Device on Postural Stability during Trip-Like Perturbations

The effectiveness of a soft wearable back-support device in enhancing postural stability was investigated under trip-like perturbations using two experimental paradigms: perturbed standing and perturbed walking. Healthy subjects completed trials under three different back-support conditions: no device, device worn with low stiffness, and device activated with high stiffness. Whole-body stability was quantified using the minimum Margin of Stability (MOS) at the point of maximal instability. Results demonstrated increased MOS during device use, indicating enhanced postural stability. In standing, MOS increased significantly with device stiffness, whereas in walking, both device conditions improved MOS relative to no device but did not differ significantly from each other. These findings highlight the potential of soft wearable back-support devices with adjustable stiffness to improve reactive balance control against external perturbations, with important implications for fall prevention. Future research should explore personalized stiffness optimization and evaluate efficacy in populations at elevated risk of falls.
May 19, 2026

You Don't Need Attention: Gated Convolutional Modeling for Watch-Based Fall Detection

Existing deep learning approaches for wearable fall detection systems rely on self-attention mechanisms that impose quadratic computational overhead, distributing weights across all time steps. This global weight distribution impairs the precise localization of the brief impact signatures that characterize falls within short, fixed-length windows. To overcome this challenge, we propose Gated-CNN, a lightweight dual-stream architecture that processes accelerometer and gyroscope streams through independent one-dimensional convolutional feature extractors, followed by (i) a sigmoid gating module that selectively suppresses uninformative background activations while amplifying fall-discriminative features, (ii) a global average pooling layer that compresses each stream into a compact fixed-length descriptor, and (iii) a shared classification head that fuses both descriptors for binary fall prediction. For offline evaluation, we evaluate the model across five wrist-mounted inertial measurement unit (IMU) datasets, achieving average F1-scores of 93%, 93%, 90%, 91%, and 90% on SmartFallMM, WEDA-Fall, FallAllD, UMAFall, and UP-Fall, outperforming Transformer baselines. For real-time evaluation, we deployed the model on a Google Pixel Watch 3 and tested across 12 participants. The model achieves an average F1-score of 97% and an accuracy of 98% with zero missed falls, showing that sigmoid gating offers a more structurally aligned and computationally efficient alternative to attention for commodity smartwatch-based fall detection.