cs.CVOct 22, 2026

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

Authors: Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo, Yuhui Deng, Huaxiong Huang

Organizations: Duke Kunshan University, Kunshan, China · University of Toronto, Toronto, Canada · Beijing Normal–Hong Kong Baptist University, Zhuhai, China · York University, Toronto, Canada

Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines (FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet) on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

Figures & tables

Appendix figures & tables23 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Mar 23, 2026

HMS-VesselNet: Hierarchical Multi-Scale Attention Network with Topology-Preserving Loss for Retinal Vessel Segmentation

Retinal vessel segmentation methods based on standard overlap losses tend to miss thin peripheral vessels because these structures occupy very few pixels and have low contrast against the background. We propose HMS-VesselNet, a hierarchical multi-scale network that processes fundus images across four parallel branches at different resolutions and combines their outputs using learned fusion weights. The training loss combines Dice, binary cross-entropy, and centerline Dice to jointly optimize area overlap and vessel continuity. Hard example mining is applied from epoch 20 onward to concentrate gradient updates on the most difficult training images. Tested on 68 images from DRIVE, STARE, and CHASE_DB1 using 5-fold cross-validation, the model achieves a mean Dice of 88.72 +/- 0.67%, Sensitivity of 90.78 +/- 1.42%, and AUC of 98.25 +/- 0.21%. In leave-one-dataset-out experiments, AUC remains above 95% on each unseen dataset. The largest improvement is in the recall of thin peripheral vessels, which are the structures most frequently missed by standard methods and most critical for early detection of diabetic retinopathy.
Oct 15, 2026

FPG-Seg: Annotation-free Retinal Vessel Topology Segmentation

State-of-the art approaches to retinal vessel segmentation typically require extensive annotations, a highly time-consuming process, reliant on clinical expertise. We present FPG-Seg, an annotation-free pipeline for retinal vessel segmentation combining classical vesselness filtering, Bayesian deep learning and topology-aware graph reconstruction to segment retinal vessel topology without manual labels. Tested across four widely used benchmark datasets for retinal vessel segmentation, FPG-Seg attains a clDice of 0.74−0.780.74{-}0.78, representing 86−98%86{-}98\% of the performance of an equivalent fully-supervised baseline, despite using no manual annotations for training or hyperparameter tuning. As part of this work, we also provide, to our knowledge, the first performance benchmark of an annotation-free vessel segmentation method on FIVES.
Sep 22, 2026

Observer Choice and Threshold Selection in Retinal Vessel Segmentation: A Subject-Separated Evaluation

The annotation used to select a segmentation threshold is part of the evaluation protocol, yet its effect is easily conflated with model quality. We examine this choice for retinal vessel segmentation using all 28 CHASE DB1 images and both human annotations. A fixed seven-fold protocol keeps both eyes of each of the 14 subjects together. Random forests and Extra Trees are fitted against observer 1 with three random seeds, yielding 42 fits. Five threshold policies share identical score maps: fixed 0.50, observer-1 tuning, observer-2 tuning, mean-observer tuning, and maximin tuning of the per-image lower observer Dice. For random forests, maximin changes the threshold in 19 of 21 fits, but worst-observer Dice decreases from 70.53 percent to 70.45 percent. The paired difference is -0.073 percentage points, with a conditional subject-bootstrap 95 percent interval of [-0.384, 0.238]. Extra Trees shows the same direction. Identical observer-1-tuned random-forest masks score 73.66 percent against observer 1 and 71.06 percent against observer 2. The results support explicit reporting of both the threshold-selection reference and evaluation reference; they do not support an accuracy benefit from maximin tuning in this cohort. All splits, raw predictions, metrics and code are supplied. AI assistance is disclosed.