cs.LGOct 27, 2026

Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability

Authors: Bartosz Morawski, Samuel J. Ward, Alex Touze, Lin-Thiri Toon, Paul R. Roberts, John Paisey, Alain B. Zemkoho

Organizations: School of Mathematical Sciences, University of Southampton, UK · School of Human Development and Health, Faculty of Medicine, University of Southampton, UK · Department of Cardiology, University Hospital Southampton NHS Foundation Trust, Southampton, UK

Abstract

This paper studies two non-transvenous implantable cardioverter-defibrillators (ICDs), namely the Subcutaneous ICD (S-ICD) and the Extravascular ICD (EV-ICD). Both avoid the complications of transvenous leads but are prone to oversensing, which can trigger inappropriate shocks associated with increased mortality. Oversensing risk is predicted by the ratio of T- or P-wave amplitude to R-wave amplitude (T:R, P:R), and these ratios vary over a 24-hour period. Yet S-ICD screening uses a single 10-second electrocardiogram (ECG) segment, and the EV-ICD has no formal screening protocol whatsoever. We present a 24-hour ambulatory screening framework for both devices which includes the first T:R analysis in an EV-ICD cohort and the first full evaluation of P:R prediction. We introduce AmpRatioNet, a family of 1D convolutional neural network architectures operating directly on the ECG signal, and benchmark it against the best existing approach - based on 2D phase space reconstruction images. Evaluation uses 4,605 clinician-annotated 10-second segments from 89 patients, with patient-level 10-fold cross-validation and bootstrap confidence intervals. AmpRatioNet-SE demonstrates superior performance on every metric in each setting with no device- or ratio-specific redesign. An explainability analysis against interpretable classical peak labelling algorithms shows that AmpRatioNet-SE's increase in error on oversensing-prone segments is up to 14 times smaller than theirs. Segment-level predictions are aggregated into a 24-hour timeline, extending S-ICD screening beyond 10 seconds and offering a plausible EV-ICD screening pathway pending device-level validation.

Figures & tables

Appendix figures & tables5 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 8, 2026

Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.
Jul 27, 2026

Automated ECG Interval Measurement and Wave Delineation Using Fast Fourier Convolution ResNet

Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts. We bridge this gap by evaluating a complete end-to-end pipeline on 10,646 clinical 12-lead ECGs and reporting the first large-scale interval measurement accuracy study with full statistical characterisation, including bias, 95% limits of agreement (Bland-Altman), bootstrap confidence intervals, and rhythm-stratified error analysis. The underlying delineation is performed by a Fast Fourier Convolution ResNet (FFCResNet), adapting local temporal convolutions with global spectral processing via FFT and augmented with register tokens for contextual feature learning. Three per-wave models (P, QRS, and T) are trained on six public databases with ECG-specific augmentation. On 10,646 ECGs, the system achieves a QT MAE of 17.5 ms [95% CI: 16.9-18.2], with a Bland-Altman bias of +8.5 ms (LoA: -68.5 to +85.5 ms); a QRS duration MAE of 14.8 ms [95% CI: 14.6-15.0], with a bias of +12.6 ms (LoA: -12.3 to +37.6 ms); and a ventricular rate MAE of 0.8 beats/min. All biases are statistically significant by the Wilcoxon signed-rank test (p < 0.001) but remain within or near published inter-observer variability bounds for sinus rhythms. Rhythm-stratified analysis reveals substantially higher QT errors for supraventricular tachycardias (SVT MAE: 75.0 ms; AVRT MAE: 85.3 ms) than for sinus bradycardia (SB MAE: 9.3 ms) and sinus rhythm (SR MAE: 8.9 ms), providing an honest characterisation of the deployment scope. Wave segmentation achieves internal Dice scores of 95.5%, 98.2%, and 96.1% for P, QRS, and T waves, respectively, and cross-database Dice scores of 78.1%, 85.5%, and 74.2%.
Aug 16, 2026

Characterising cardiac tissue properties with graph neural networks

Characterising electrophysiological properties of cardiac tissue efficiently and accurately from spatially sparse intracardiac measurements is clinically important for localising ablation targets and improving arrhythmia treatment. We developed a graph neural network-based framework trained on synthetic electrogram signals on 2D flat surfaces to identify areas of interest in the context of cardiac ablation for premature ventricular complexes (PVCs). Our method achieved an average precision of 0.96, 0.97, and 0.95 for the detection of single-patch fibrosis, rapid depolarisation and high excitability, respectively. The trained model can then be applied to 2D curved surfaces with few-shot fine-tuning, demonstrating its generalisation capability. Future work will develop this framework further for clinical use in PVC ablation.