cs.AINov 5, 2026

Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

Authors: Yu Cao, Haiyan Xu, Xiaohan Li, Jian Yang, Yuqing Feng, Wei Wang, Haomin Li

Organizations: Clinical Data Center, Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Children and Adolescent's Health and Diseases, China · ECG Department, Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Children and Adolescent's Health and Diseases, China · The College of Biomedical Engineering and Instrument Science, Zhejiang University, China · Department of Cardiology, Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Children and Adolescent's Health and Diseases, China

Abstract

Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.

Explore similar work

May 1, 2026

Label-Conditioned Cross-Modal Fusion for Adult-to-Pediatric ECG Transfer via Curriculum-Gated Contrastive Alignment

Automated pediatric electrocardiogram (ECG) interpretation remains challenging because developmental differences in heart rate, intervals, and waveforms limit the transferability of models trained mainly on adult data, while expert-labeled pediatric ECG cohorts are scarce. We propose PEACE (Pediatric-Adult ECG Alignment via Cross-modal Enhancement), an adult-to-pediatric ECG transfer framework pretrained on MIMIC-IV ECGs and adapted to pediatric targets. PEACE integrates label-specific bidirectional contrastive learning (LSBC) to align ECG representations with diagnostic semantics and curriculum adaptive fusion (CAF) to stabilize optimization under limited pediatric supervision. Label-conditioned short text descriptors provide auxiliary semantic supervision during training, whereas inference requires ECG signals only. On ZZU-pECG, PEACE achieves macro-average AUCs of 59.39%, 81.74%, and 91.56% under zero-shot, 50-shot, and full fine-tuning settings, respectively, outperforming ECG-only, multimodal, and generic domain adaptation baselines including DANN and MMD. On PTB-XL, it reaches 96.90% macro-average AUC after full fine-tuning over nine harmonized labels with nonzero mapped incidence. Gradient-based attention maps show increased saliency around QRS voltage and morphology regions for chamber-related RVH and around QRS-to-T/repolarization intervals for LQTS, broadly consistent with ECG regions commonly inspected during routine interpretation. These results suggest that adult-scale ECG pretraining coupled with rhythm, morphology, and ST-T repolarization semantic descriptors improves transferable pediatric diagnosis under label scarcity while preserving clinically interpretable waveform focus.
Jul 17, 2026

Knowledge-Guided Cross-Modal Fusion for Adult-to-Pediatric ECG Transfer via Label-Conditioned Contrastive Alignment

Adult and pediatric electrocardiogram (ECG) interpretation relies on age-sensitive criteria, and models pretrained mainly on adult ECGs often transfer poorly to pediatric populations when pediatric labels are scarce. Existing multimodal ECG--text methods typically align waveforms and text at the global sample level, entangling evidence from co-occurring diagnoses and limiting transfer under this gap. We propose Pediatric-Adult ECG Alignment via Cross-modal Enhancement (PEACE), a knowledge-guided framework pretrained on the largely adult MIMIC-IV ECG corpus. PEACE describes each diagnosis along rhythm, morphology, and ST--T axes and, per recording, composes only positive-label descriptors into three axis tokens and a fused embedding. A label query network (LQN) uses diagnostic labels as queries to cross-attend over ECG tokens and axis tokens, while label set aware bidirectional contrastive learning (LSBC) aligns pooled ECG features with the fused embedding when recordings share diagnoses. Curriculum adaptive fusion (CAF) gates alignment strength according to smoothed classification loss and training progress, limiting disruption during early optimization. The knowledge branch is used only for training supervision; inference uses ECG signals alone. On ZZU-pECG, PEACE reaches macro average AUCs of 59.39%, 81.74%, and 91.56% under zero-shot, 50-shot, and full fine-tuning, with the clearest gains over foundation and knowledge-pretraining baselines under limited supervision; versus domain adaptation initializations, zero-shot improves substantially while 50-shot AUC is comparable to DANN. After fine-tuning on PTB-XL, PEACE reaches 96.90% macro average AUC over nine harmonized labels. Ablations confirm that label-conditioned knowledge alignment, rather than global text fusion, is the key driver of pediatric transfer gains.
Apr 25, 2026

Domain-Adapted Fine-Tuning of ECG Foundation Models for Multi-Label Structural Heart Disease Screening

Transthoracic echocardiography is the reference standard for confirming structural heart disease (SHD), but first-line screening is limited by cost, workflow burden, and specialist availability. We evaluated whether open pretrained electrocardiogram (ECG) foundation models can support echo-confirmed multi-label SHD detection using the public EchoNext Mini-Model benchmark. Six echocardiography-derived abnormalities were targeted: reduced left ventricular ejection fraction, increased left ventricular wall thickness, aortic stenosis, mitral regurgitation, tricuspid regurgitation, and right ventricular systolic dysfunction. Under a common pipeline, we compared engineered ECG features with gradient boosting, end-to-end waveform learning from scratch, and transfer from open ECG foundation models. We then applied in-domain self-supervised adaptation of an ECG foundation model (ECG-FM) on EchoNext waveforms followed by selective supervised fine-tuning, and evaluated trade-offs between discrimination and adaptation cost. Adapted ECG-FM models achieved the best overall performance: peak macro-AUROC 0.8509 and macro-AUPRC 0.4297, while a parameter-efficient operating point preserved AUROC (0.8501) and attained the highest fixed-threshold macro-F1 0.3691. Late fusion with covariates did not improve threshold-independent discrimination, and evaluated LoRA, alternative backbones, and mixture-of-foundations strategies did not surpass the best adapted single-backbone models. These results indicate that for ECG-based case finding and echocardiography triage, combining target-domain self-supervised adaptation with selective supervised updating of a pretrained ECG backbone is the most effective transfer strategy.