An anatomical pose provides interpretable joint structure, but no fixed set of physical landmarks can fully specify a person's movement. We introduce PRISM, a complementary representation that characterizes repetitive movement using tracked masks and dense optical flow. Torso-relative flow measures intensity, frame-wise mask variation measures spatial extent, signed-flow recurrence estimates frequency, and persistent sliding-window geometry describes the rhythmicity of the movement. Across 1,890 synthetic conditions, the measurements recover controlled speed, amplitude, and frequency while exposing observation limits. An idealized hand-motion experiment demonstrates variation omitted by identical exact COCO-17 trajectories; controlled corruption experiments separately examine measurement sensitivity. Audits of two pose methods on the same data cohort and 36,930 external skeleton clips document incomplete observation and dependence on processing choices. In 1,404 annotated complex stereotypical motor movement bouts from six autistic participants, total flow converges with pose motion, while matched-coordinate examples and repeated-session profiles show differences in intensity, extent, frequency, and rhythmicity within behavior labels. A separate VLM comparison evaluates quantitative frequency estimation, and a profile-conditioned decoder links the measurements to illustrative skeletal movements. PRISM connects numerical profiles to visible examples, providing an interpretable way to compare how the same behavior is expressed beyond its label or event count.
Figures & tables
Figure 1: PRISM overview. The tracked mask defines target-person support. Torso-relative flow yields intensity; camera-corrected total signed flow yields recurrence frequency and sliding-window periodicity. Common-grid masks independently yield frame-wise RMS extent. Event boundaries yield duration and between-bout timing.
Geometry
Iρ
Eρ
fρ
Arm flapping
0.973
0.969
0.962
Body rocking
0.933
0.974
0.970
Hand flapping
—
0.950
0.960
Head banging
0.984
0.958
0.966
Head shaking
0.699
0.858
0.980
Table 1: Clean construct recovery. Spearman correlations across 225 conditions per geometry. Intensity is compared with projected speed, extent with angular excursion, and frequency with generating rate.
Phase modulation ε
Mean PS
Mean cycle CV
0
.949
.000
.15
.788
.034
.30
.672
.068
.60
.514
.135
Table 2: Matched Eulerian controls. Eight seeds per modulation level. Intensity, extent, and estimated frequency are matched before persistence is computed. Measurements use exact fields, isolating the descriptors from optical-flow estimation error.
Figure 2: Complementary real-video measurements. Selected bouts share participant, behavior, and source recording. The shaded coordinate is matched within six percentile points, while other coordinate ranks can differ. Matching one measurement does not establish equivalent underlying movement or exclude observation error.
Figure 3: Repeated-session movement profiles. Points show behavior-specific medians and bars show bout-level interquartile ranges for Participants 1 and 4. Squares and circles distinguish studies; lines connect recordings within a study. Each summary requires at least three available bouts for that coordinate. Same-day recordings have separate run labels. The profiles are descriptive and do not establish a population-level longitudinal effect.
Method
MAE (Hz)
Answered
Success
PRISM
0.178
40/40
85.0%
Grok 4.20
2.225
40/40
7.5%
Grok 4.3 (low)
0.393
14/40
17.5%
Grok 4.7 (low)
0.419
37/40
47.5%
Qwen3-VL 2B (4-bit)
0.617
40/40
40.0%
Table 3: Frequency measurement at 10 fps. MAE is computed over valid answers; success is the percentage of all 40 clips within 20% of the generating frequency. PRISM additionally receives tracked masks.
Figure 4: Skeleton Lab controls. Five repetitive geometries vary generating movement properties. Observation perturbations test measurement sensitivity under the benchmark conditions.
Figure 5: Construct and availability logic. Movements sharing a behavior label can differ in their expression. The framework reports complementary measurements together with availability; unavailable estimates are not interpreted as zero movement or zero organization.
Figure 6: Construct recovery across movement geometries. The unperturbed benchmark contains 1,125 clips spanning five movement geometries, five frequencies, five durations, three amplitudes, and three seeds. Intensity and extent are compared with references in different units, so their agreement concerns whether they follow changes in speed and excursion rather than numerical equality. Estimated and generating frequencies are both measured in Hz. These comparisons assess recovery within the tested geometries and recording conditions.
Figure 7: Sensitivity to observation perturbations. Perturbed clips are compared with matched unperturbed counterparts to examine how observation changes affect each PRISM measurement. Camera-motion conditions use the known synthetic transforms for correction; they therefore test downstream measurements under exact correction rather than the accuracy of estimated camera stabilization.
Figure 8: Sensitivity to observation perturbations, continued. Silhouette extent under the tested observation perturbations, compared with matched unperturbed counterparts.
Figure 9: Sensitivity to observation perturbations, continued. Estimated frequency under the tested observation perturbations, compared with matched unperturbed counterparts.
Figure 10: Sensitivity to observation perturbations, continued. Rhythmicity under the tested observation perturbations, compared with matched unperturbed counterparts.
Behavior
Intensity
Extent
Frequency (Hz)
PS
Duration (s)
IBI (s)
Flap
0.094 [0.062,0.135]
0.319 [0.267,0.380]
0.641 [0.363,1.119]
0.032 [0.012,0.058]
2.586 [1.663,4.381]
3.511 [1.037,10.715]
Flap–rock
0.192 [0.123,0.270]
0.482 [0.395,0.567]
1.141 [0.849,1.682]
0.131 [0.073,0.236]
4.288 [2.939,6.457]
2.501 [0.439,8.505]
Rock
0.173 [0.114,0.239]
0.418 [0.349,0.533]
0.763 [0.662,0.836]
0.352 [0.187,0.477]
6.241 [3.134,12.943]
4.421 [1.563,13.984]
Table 4: Real-video distributions. Median [Q25,Q75] for each available measurement in the primary frequency analysis. Intensity is in approximate tracked body heights/s, frequency in Hz, and duration and IBI in seconds. Extent measures area-normalized silhouette RMS variation. Available bout counts differ across measurements.
Label
Total
I
E
f
PS
Flap
616
616
616
199
218
Flap–rock
188
186
188
76
111
Rock
600
597
599
440
433
Table 5: Measurement availability. Available counts among all bouts with each label. Frequency uses the primary quality-control rule.
Comparison
Bouts
Pooled ρ [95% CI]
Within-stratum rank association [95% CI]
Total motion
1379
0.817 [0.680,0.907]
0.764 [0.715,0.820]
Articulated / residual
1376
0.695 [0.548,0.777]
0.657 [0.578,0.732]
Torso translation
1376
0.734 [0.544,0.876]
0.628 [0.554,0.706]
Table 6: Pose–flow agreement. Pooled Spearman correlations and correlations of ranks within participant and behavior. Intervals are participant-clustered 95% bootstrap intervals from 2,000 successful replicates.
Source
Units
c=.3
c=.5
c=.7
MediaPipe, same cohort
1,404
76.5%
73.8%
64.7%
SAM-crop pose, same cohort
1,404
69.9%
64.2%
58.3%
ASDMotion, external
36,930
57.9%
51.4%
39.8%
Table 7: Pose coverage after confidence filtering. Median fraction of retained landmark observations per unit at threshold c . The two AQSM sources cover the same cohort, while ASDMotion is external. Thresholds use each system’s own confidence scale, and coverage does not measure accuracy.
Figure 11: Illustrative pose sequences. Examples give context for the coverage and continuity audits. Abrupt changes are candidates for inspection, not verified pose errors; quantitative counts are reported in the audit tables.
Observation
Intensity
Extent
Frequency
Calibrated multiview
12.80
3.61
0.20
Favorable single view
14.87
1.11
0.24
Random single view
17.76
6.20
0.20
Unfavorable single view
21.35
4.32
0.45
Table 8: Landmark recovery across observation conditions. Pooled median calibrated relative error, expressed as a percentage. This experiment evaluates landmark measurements separately from the main PRISM profiles.
Training
Median error
f MAE
PS MAE
Clipped
144
0.196
0.127
0.110
15
576
0.135
0.108
0.086
3
1440
0.087
0.114
0.070
0
Table 9: Neural sample-size comparison. Architecture, target profiles, and reference scales are held fixed. Frequency MAE is measured in Hz.
Method
Median error
f MAE
PS MAE
≤.35
Neural
0.087
0.114
0.070
47/54
Random mean
0.598
0.483
0.182
0/54
Retrieval
0.068
0.058
0.020
54/54
Without PS
0.230
0.032
0.159
35/54
Table 10: Comparison with 1,440 library clips. All methods use the same 54 targets and reference scales. Frequency MAE is in Hz; the last column counts profile errors at most .35.
Humans recognize movements effortlessly, even from noisy and complex visual input. But what information in the stimulus allows humans to rapidly classify movements? No framework has systematically compared different strategies of movement analysis to address this question. Here, we used videos of 16 daily activities from the MoVi dataset and compared three strategies: Temporal Movement Primitives (TMPs), which decompose movements into weighted sums of temporally smooth basis functions; Legendre polynomial coefficients, which project joint-coordinate trajectories onto an orthogonal polynomial basis; and Autoencoder latent embeddings. Legendre coefficients and TMPs achieved the highest classifier accuracy, followed by autoencoders. We found two discriminative features for movement classification. The most informative is the general posture of the body, the average spatial configuration that distinguishes one activity from another. Additionally, we identified 9 critical joints that are most predictive for movement classification. Interestingly, good classification accuracy did not automatically lead to good movement generation: when we reconstructed movements for each activity, TMPs preserved the temporal dynamics and produced perceptually natural motion, whereas reconstructions from Legendre coefficients retained only the average posture and appeared frozen. These results reveal a dissociation in how movement information is organized: the static configuration of the body suffices to classify what activity is performed, but the temporal dynamics of movement are required to reconstruct how it unfolds. This distinction clarifies which features the visual system may rely upon for rapid action recognition, and suggests that postural features could enable efficient movement screening in clinical applications, while dynamic information remain essential wherever movement generation is the goal.
Arefeh Farahmandi, Gunnar Blohm
Centre for Neuroscience Studies Queen’s University Kingson, Ontario, Canada
Voluntary movements have long been hypothesised to be comprised of discrete primitives called submovements, as a descriptive model of human motor behaviour. However, existing methods scale poorly, and no principled method exists to determine whether a decomposition is informative. We propose a spatiotemporal kernel correlation between primitive pairs as an identifiability criterion. Submovement-Identifiable Decomposition (Sub-ID) embeds this criterion in its adaptive-ridge regularisation, biasing the optimiser toward low-correlation solutions. Identifiability is lost when primitives become collinear and recovered when they diverge spatially. On synthetic data, Sub-ID recovers ground-truth parameter distributions where existing methods fail; furthermore, when primitives overlap too heavily to be distinguished, the method explicitly detects this ambiguity rather than outputting misleading results. Sub-ID extracts submovements from real three-dimensional, long-horizon movements, a regime no prior method addresses. This method has the potential to identify physiologically grounded primitives for motor control research and imitation learning.
Adrian Prados, James Hermus, Ramon Barber +1
Universidad Carlos III de Madrid, Leganes, Spain · Idiap Research Institute, Martigny, Switzerland · Ecole Polytechnique F´ed´erale de Lausanne (EPFL), Lausanne, Switzerland
Recovering 3D human motion from sparse wearable sensors is challenging due to the inherent noise, occlusion, and instability of real-world tracking signals. Existing approaches are restricted to fixed sensor configurations and, when built on diffusion models, are computationally prohibitive for real-time deployment. We propose OmniPoser, a universal framework that recovers full-body SMPL motion from a flexible combination of heterogeneous inputs, such as 3D keypoints, sparse IMU rotations, head-mounted 6-DoF poses, or any subset thereof, within a single model. OmniPoser introduces a cross-modal masking mechanism paired with a Masked Conditioning Encoder, enabling one architecture to incorporate diverse sensor configurations through a masked design. A decoupled dual-stream generative backbone generates complete motion via Conditional Flow Matching, requiring only a single ODE integration step at inference. Across three settings and seven benchmarks, including in-the-wild Nymeria and Ego-Exo4D datasets, OmniPoser performs on par with state-of-the-art methods while running at over 700 FPS. The project page is available at https://jamesbridgewater51.github.io/omniposer-eccv/.
Minghao Liu, Tutian Tang
Shanghai Jiao Tong University, China · Shanghai Artificial Intelligence Laboratory, China