cs.CVNov 21, 2026

Diagnosing Verbalized Confidence in a Medical Vision-Language Model for Selective Prediction on Colorectal Histopathology Patches

Authors: Anay Sinhal, Amit Sinhal, Ashish Pandey, Arpana Sinhal

Organizations: Department of Computer and Information Science and Engineering, University of Florida, Gainesville, FL, U.S.A. · Department of Medicine, University of Florida, Gainesville, FL, U.S.A. · Department of Computer Science and Engineering, JK Lakshmipat University, Jaipur, India. · Department of Data Science and Engineering, Manipal University Jaipur, Jaipur, India. · 

Abstract

Flagging uncertain histopathology patches for specialist review needs a confidence that is higher when the model is right. We test whether an open medical vision-language model emits one. MedGemma-27b-it and its base Gemma-3-27b-it were run zero-shot under one prompt on 10,004 PathMNIST validation patches and 7,180 patches of a patient-disjoint external cohort. Both are too inaccurate to deploy (40.6% and 35.5%); the object of study is the confidence. MedGemma's verbalized confidence puts 96% of patches at one value; its confidence-correctness AUROC is 0.499 and 0.528, and routing by it moves selective-accuracy AUC by -0.004 and +0.037. Gemma-3 spreads its confidence over nine values, reaches AUROC 0.70, and gains +0.114 and +0.115. MedGemma's label-token probabilities do not rescue it: their validation advantage reverses where the top-20 alternatives include every class. On 1,800-patch subsets of each cohort, stratified on correctness and reweighted to the full splits, agreement across five prompt variants beats random by +0.123 and +0.106, and wording-only paraphrases give +0.100 and, externally and in direction only, +0.054; agreement's external margins over confidence do not survive slide-level clustering. Under one restructured prompt variant, MedGemma's stated confidence routes (+0.112, +0.141), so the failure is tied to a prompt chosen for macro F1.

Figures & tables

Explore similar work

Nov 21, 2026

Elicitation format changes zero-shot classification accuracy in a medical vision-language model: a two-center evaluation on colorectal histopathology

Background. Verbalized confidence from a hosted medical vision-language model is usually treated as packaging around an unchanged prediction. Methods. We held a nine-class colorectal histopathology prompt fixed except for the requested response format and evaluated MedGemma-27b-it on 10,004 validation and 7,180 external-center PathMNIST patches, with preregistered endpoints, randomized ties, and random floors recomputed for each patch set. Results. Requesting probabilities over all nine classes instead of a ranked top-3 reduced accuracy by 14.8 points on validation, -0.1475 [-0.1594, -0.1353], and 13.4 at the external center, -0.1341 [-0.1484, -0.1196], against chance accuracy of 0.1111. The nine-class prompt uniquely forbade commentary, reasoning, and a chosen answer; removing that prohibition at matched cardinality and token budget recovered +0.1878 [+0.1623, +0.2134] and +0.1911 [+0.1648, +0.2181], while changing cardinality with the prohibition absent moved accuracy by -0.0013 [-0.0300, +0.0280] and -0.0214 [-0.0494, +0.0071]. The nine-class format returned no parseable distribution on 7.6 and 7.7 percent of patches, mostly zero vectors in the two least-textured classes, and deferring these failures first explained its measurable selective-prediction gain. Across four vision-capable models, accuracy did not grade the cost: two models matched on accuracy differed five- to sevenfold. First-token logit entropy routed better than any elicited signal, +0.1820 [+0.1722, +0.1974] versus +0.0493 [+0.0377, +0.0649] relative to each signal's random floor. Conclusions. Response format changes a medical vision-language classifier, and the operative component here was the instruction suppressing an answer. Use logits when available; otherwise request a short ranked list without prohibiting reasoning or a chosen answer.
Oct 23, 2026

PathJev: Decision-Native Vision-Language Modelling for Histopathology

Vision-language models used for decisions in histopathology rarely return calibrated probabilities over the candidates a user cares about. Decision-native models write a question and a candidate set chosen at run time into the input and return a normalised distribution from a small decision head in one forward pass. We build PathJev-P, a decision-native model for histopathology: MedGemma-1.5-4B with LoRA adapters and a decision head, trained on 40,000 patch states from three public collections whose expert labels are turned into typed questions with organ-specific candidate sets and a "none of these" option. In a comparison over 3 seeds with an analysis plan fixed before testing, on test sets without documented overlap with the training data of the backbone, PathJev-P is more accurate than a generative model trained with the same backbone, data and selection rule, the zero-shot pathology model CONCH and a general medical decision model (balanced accuracy 0.541 against 0.492, 0.345 and 0.213); its advantage over the generative model comes from two organs absent from training. The calibration advantage depends on how the generative model's probabilities are read out. With the summed candidate log-likelihood used in previous work, PathJev-P has the lower calibration error (ECE 0.204 against 0.279); with a length-normalised read-out of the same generative model, examined post hoc, the two have similar mean calibration error (0.201) and the generative model is better calibrated on the unseen organs, where PathJev-P remains over-confident. A supervised linear probe on a pathology foundation model is better calibrated in every setting. In a qualitative whole-slide demonstration, PathJev-P labels unsupervised tissue clusters with abstention and separates carcinoma from other tissue while running the model on a fraction of the tiles.
Jun 14, 2026

Adapt or Calibrate? How Local Labels Buy Certified Coverage in Medical VQA

An answer from a vision-language model (VLM) to a medical image question can be accepted without review only under a threshold bounding the error of accepted answers, and certifying that bound costs local labels. We ask what such labels can certify for nine confidence estimators on five general-purpose open-weight VLMs and three medical VQA benchmarks under Learn-then-Test, with the question as the exchangeable unit. Estimators trained on natural images transfer poorly: the best pooled certificate covers 11.5% of SLAKE answers at a 20% error tolerance and nothing on PATH-VQA. With 1,000 labeled SLAKE questions, adapting a probe on half of them raises pooled certified coverage from 6.8% to 37.6% (0.0% to 30.6% with the image as the unit), above the best threshold-only estimator (11.3%). On PATH-VQA, adaptation certifies 11.4% with 2,500 labels; thresholds alone certify nothing. Yet for strong single models, small budgets are better spent on the threshold. A question-only classifier recovers much of adaptation's ranking gain but certifies far less. Neither procedure yields a pooled certificate at 10%, and nothing is certified at 5%. A blank image removes 61% of correct answers, yet on GMAI-MMBench no trained probe is less confident on answers unchanged by image replacement.