Superellipse Function: A Powerful Geometric Tool for the Design and Deformation Modeling of Tendon-Driven Continuum Manipulators With Flexural Patterns Experiencing Tension Loss
Authors: Yang Liu, Farshid Alambeigi
Organizations: Y. Liu is with the Walker Department of Mechanical Engineering at the University of Texas at Austin, Austin, TX, 78712, USA. · F. Alambeigi is with the Department of Mechanical Engineering at Rice University, and The Bookout Center at Houston Methodist Research Institute.
In this article, we feature the Superellipse function as a geometric and versatile tool for effective design and modeling of flexural patterns (FPs) in tendon-driven continuum manipulators (TD-CMs) with discontinuous cross section geometries. We also propose a unique complementary mathematical framework and solution algorithm for modeling the effects of distributed and concentrated friction forces- caused by partially-constrained tendons- on tension loss and deformation behavior of a TD-CM designed using a Superellipse function. Particularly, by employing this geometric function, we establish four intuitive functional mappings relating the manipulator's geometric parameters, kinematics, and deformation behavior. Thanks to the features of these intuitive mappings and Superellipse function, we then introduce the concepts of design space and design curve to facilitate intuitive design of a TD-CM with a generic FP geometry experiencing tendon tension loss. To thoroughly evaluate the performance of this novel framework and its aforementioned features, we performed various simulation and experimental studies on TD-CMs designed and fabricated based on a Superellipse function. Results were then analyzed and compared using different error metrics.
Figures & tables
Fig. 1: Conceptual illustration of a superellipse function (SEF) serving as a geometric tool for design of TD-CMs with discontinuous cross-section geometries. As shown, simply by changing the exponent n in an SEF parametric formulation, different geometric shapes can be assumed for FPs of a TD-CM.
Fig. 2: Conceptual illustration of a TD-CM with circular cross sectional geometry and N evenly and symmetrically distributed FPs designed based on an SEF. Figure also shows the parameters and reference frames used to model such TD-CMs.
Fig. 3: Figure shows the internal forces acting on the tendon within the Dnotched and Dtubular domains including the tendon tension T(s) , distributed normal force fn(s) , and distributed friction force ff(s) ), as well as the concentrated normal force FN(s) , and concentrated friction force FF(s) at the exit and entry points from one domain to the other one.
Fig. 4: Simulation results of TD-CMs with three different superellipse-geometric FPS (i.e., S1⋆∼S3⋆ ) actuated with an identical input tension Tbase= 30 N and considered friction coefficient μ = 0.5: (a) Comparison and illustration of the TD-CMs’ deformation behaviors; (b) Comparison of the midline curvatures along midline arc length s for the considered TD-CMs; (c) Comparison of the tendon tension distribution between the scenarios S1⋆∼S3⋆ ; (d) Comparison of internal distributed forces along the tendon channel for the three selected TD-CMs; (e) Comparison of concentrated forces at the discontinuity between S1⋆∼S3⋆ ; (f) The surface represents the design space showing the space of all possible exponent value n and tip displacement d when the input tension is changing from T= 0 ∼ 30 N. The design space also includes design curves S1∼S3 representing the tip Deflection d of TD-CMs with specific FP geometries corresponding to exponent n =1, 3, and 5 in ( 1 ).
Fig. 5: Simulation results of TD-CMs with three different friction coefficients (i.e., M1⋆∼M3⋆ ) actuated with an identical input tension Tbase= 30 N: (a) Comparison and illustration of the TD-CMs’ deformation behaviors; (b) Comparison of the midline curvatures along midline arc length s for the considered friction coefficients; (c) Comparison of the tendon tension distribution between these scenarios M1⋆∼M3⋆ ; (d) Comparison of internal distributed forces along the tendon channel for the three selected friction coefficients; (e) Comparison of concentrated forces at the discontinuity between M1⋆∼M3⋆ ; (f) The surface represents the design space showing the space of all possible friction coefficients μ , and tip displacement d when the input tension is changing from Tbase= 0 ∼ 30 N. The design space also includes design curves M1∼M3 representing the tip Deflection d of TD-CMs with specific friction coefficients corresponding to μ = 0.1, 0.5, and 1 in ( 19 ).
Fig. 6: (a) Overview of the utilized experimental setup comprising of an additively manufactured TD-CM, tension sensor for measuring the tendon tension, linear stage for actuation of the manipulator, and the Vicon motion capture system used to measure the deformation behavior of the manipulator during actuation; (b) Figure shows the geometry of the considered FPs for the fabricated TD-CMs corresponding to the exponent value n= 1, 2, and 3 in the SEF.
Fig. 7: Figures (a)-(c) compare the experimental results and the model predictions of the midline shape for TD-CMs with three different FPs based on the SEF geometry defined by exponent values n= 1, 2, and 3 at three different input tensions Tbase= 12, 16, and 20 N, respectively. Figures 7 (d)-(f) also show the corresponding estimated tendon tension loss in the considered cases calculated by the proposed modeling framework.
Input Tension
Exponent Value n
1
2
3
Tbase= 12 N
dsim
3.68 mm
5.61 mm
6.79 mm
dmean, exp
6.34 mm
7.85 mm
9.25 mm
σ
0.13 mm
0.58 mm
0.40 mm
MAPE
41.81%
28.38%
26.53%
MAE
2.65 mm
2.23 mm
2.45 mm
Eshape
0.88 mm
0.82 mm
0.75 mm
TABLE I: Experimental results for the TD-CM’s tip deflection at Tbase= 12 N, 16 N and 20 N in three repeated trials with four different FPs (i.e., exponent value n= 1, 2, 3). σ represents the standard deviation of TD-CM’s tip deflection between experiments and model outputs.
Fig. 8: Figure compares MAE and Eshape with the averaged measured tip deflection in three repeated trials ( dmean, exp ) for Tbase= 12 N, 16 N and 20 N and three different FPs (i.e., exponent value n= 1, 2, 3).
Rerouting the tendon path in tendon driven continuum manipulators (TDCMs) enables a broad range of deformation modes. This work presents a Reconfigurable TDCM design which allows independent rotation of intermediate spacer disks, thereby locally rerouting the tendon and achieving non-trivial backbone spatial deformations. Two such designs, (a) Manual Disk Locked (MDL) and (b) Continuous Disk Rotor (CDR) manipulators are presented to achieve disk rotations before and during operation, respectively. A predictive static model based on the piecewise constant strain (PCS) assumption is developed within a potential energy minimization framework, incorporating (a) disk rotations, (b) discrete tendon paths between disk segments, (c) rigid thickness of spacer disks, and (d) elasticity of the tendons. The model is validated against experimental results, demonstrating an average tip error of 1.2% of the manipulator's total length for parallel tendon routing and around 3% for the case when multiple disks are rotated. The computation time is an order of magnitude lower than the state of the art Cosserat rod solver.
Sabyasachi Dash, Yangkun Liu, Will Hunter +2
Department of Industrial & Enterprise Systems Engineering, University of Illinois Urbana-Champaign · Department of Mechanical Science & Engineering, University of Illinois Urbana-Champaign
In tendon driven continuum manipulators (TDCMs), reconfiguring the tendon routing enables tailored spatial deformation of the backbone. This work presents a design in which tendons can be rerouted either prior to or after actuation by actively rotating the individual spacer disks. Each disk rotation thus adds a degree of freedom to the actuation space, complicating the mapping from a desired backbone curve to the corresponding actuator inputs. However, when the backbone shape is projected into an intermediate space defined by curvature and torsion (C-T), patterns emerge that highlight which disks are most influential in achieving a global shape. This insight enables a simplified, sequential shape-matching strategy: first, the proximal and intermediate disks are rotated to approximate the global shape; then, the distal disks are adjusted to fine-tune the end-effector position with minimal impact on the overall shape. The proposed actuation framework offers a model-free alternative to conventional control approaches, bypassing the complexities of modeling reconfigurable TDCMs.
Sabyasachi Dash, John Golden, Girish Krishnan
Department of Industrial and Enterprise Systems Engineering, University of Illinois Urbana-Champaign · Department of Mechanical Science and Engineering, University of Illinois, Urbana-Champaign
Many planning and control tasks for tendon-driven continuum robots (TDCRs) require the complete Cartesian backbone geometry. We present a reduced Cartesian framework for planar, axially compressible TDCRs that propagates equilibrium configurations along prescribed tendon-force and tendon-displacement trajectories. The backbone is represented by two global position fields. Following exact variation, a Taylor-Galerkin reduction condenses prescribed spatial properties and distributed loads into offline moment vectors, yielding analytic reduced residuals and Jacobians without online spatial quadrature or numerical differentiation. Analytical differentiation and residual correction yield first-order rate systems requiring one fixed-dimensional linear solve per rate evaluation after initial equilibrium alignment on a regular branch. Across four simulated cases covering variable tendon routing, nonuniform geometry, axial compression, and their combined effects, the propagated Cartesian shapes and distributed strains closely match pointwise geometrically variable-strain (GVS) equilibrium solutions. Residual correction suppresses propagation drift across the tested step sizes while adding only about 0.98% to the mean update time of uncorrected Euler. The proposed method requires 0.508 ms per update on average, approximately 11 times faster than pointwise GVS solves. Displacement-driven experiments yield a maximum normalized mean backbone position error of 1.02% and a maximum end-effector position error of 0.28%. These results support efficient and accurate Cartesian full-shape prediction along prescribed actuation paths.