AI dose-prediction models generate patient-specific 3D dose distributions from patient anatomy. Yet these predictions can still miss structure-level clinical dose targets. Once deployed, most existing predictors offer no direct mechanism to correct such deviations, deferring target enforcement to downstream plan optimization. We introduce DoseSteer, an inference-time framework that steers frozen diffusion-based dose prediction models towards specified clinical targets without retraining. To meet clinical targets while preserving overall dose prediction quality, we propose Dual-Response Guidance (DRG), a structure-centric algorithm that probes the model's responses to perturbations in each structure's noisy dose and context and jointly solves for per-structure steering strengths. Across five dataset-model configurations spanning three diffusion architectures and three datasets, DRG outperforms 12 training-free baselines under identical reference-derived target proxies, removing at least 97% of the target error, reducing the official dose error by 7.8% on average, and improving dose fidelity outside the steered structures. DoseSteer reconciles learned anatomical dose priors with explicit structure-level targets at test time, establishing a principled, training-free mechanism to refine AI dose predictions prior to plan optimization. Code is available at https://github.com/csp2002/DoseSteer.
Figures & tables
Figure 1: Motivation of DoseSteer. (a) A dose predictor usually maps patient anatomy to a dose with no direct control during prediction, deferring clinical targets to downstream plan optimization. (b) In DoseSteer, clinical targets (e.g., PTV D95 or OAR mean dose) enter at inference, where DRG steers a frozen diffusion predictor to resolve deviations (e.g., bringing larynx mean dose from 36.9 Gy to its 23.2 Gy target) prior to plan optimization.
Figure 2: Geometric intuition for the two levers of DRG. Solid curve: surface Mc of plausible doses under c ; gray plane: target-satisfying surface. (a) The noise response Nk≈J1k moves x^0 along Mc . (b) The context response Ck jumps towards a neighboring surface where structure k is re-weighted. (c, d) Solving jointly for all 2K strengths combines context jumps across neighboring surfaces with within-surface noise steps to reach the target surface near the model’s re-weighted belief ( Sec. 3.4 ). Note that the tip-to-tail path in (d) is a geometric decomposition of the single simultaneous update Δ=∑k(αkNk+βkCk) , not a sequential structure-by-structure pass.
Dataset
Source
Site
Technique
Image
Train / val / test plans
OARs
PTVs
K
OpenKBP
Challenge
Head and neck
IMRT
CT
200 / 40 / 100
1–7 (6)
1–3 (2)
2–9 (8)
GDP-HMM
Challenge
Head and neck, lung
IMRT, VMAT
CT
2727 / 148 / 356
8–27 (17)
1–3 (2)
9–28 (19)
Local
In-house
Brain
GK
MR
101 / 16 / 38
2–5 (2)
1–3 (1)
3–7 (3)
Table 1: Dataset statistics. Dataset splits, and the steered structures of a test plan: OARs, PTVs and their total K , as range (median).
Target error
Official metric
DVH score
Outside error
Method
DD
MD
DiT
GDP
Local
DD
MD
DiT
GDP
Local
DD
MD
DiT
GDP
Local
DD
MD
DiT
GDP
Local
Clean-space correction and alternating inference
Direct edit
100.0
100.0
100.0
100.0
100.0
0.8
−0.5
1.0
3.6
3.0
40.5
42.9
43.5
43.8
44.7
0.0
0.0
0.0
0.0
0.0
DDNM [ 56 ]
99.9
99.9
100.0
100.0
100.0
1.0
−0.3
2.6
8.9
2.2
42.4
42.1
45.9
50.0
42.4
0.4
0.7
1.8
4.2
−2.0
DiffPIR [ 65 ]
99.9
99.9
100.0
100.0
100.0
1.1
−0.3
2.6
9.8
2.3
42.4
41.8
45.3
49.1
43.1
0.5
0.7
1.7
5.0
−1.8
DAPS [ 62 ]
9.6
10.3
13.8
1.3
−1.0
−2.7
−2.9
−1.9
−2.1
−8.4
5.7
3.7
7.7
3.0
5.2
−2.7
−2.6
−1.7
−2.1
−5.1
Table 2: Main quantitative comparison across five settings. Percentage error reduction relative to unsteered predictions (higher is better) on OpenKBP with DoseDiff (DD), MD-Dose (MD), and DoseDiT (DiT), GDP-HMM with DoseDiff (GDP), and the local cohort with DoseDiff (Local). All methods share identical targets, initial noise, and validation rules. Best per column in bold (target-error column unbolded as direct edit, DDNM, and DiffPIR enforce targets directly to ≥99.9% , while DRG achieves ≥97.4% ).
Figure 3: DRG can meet the targets while reducing overall dose error. Target error reduction against the gain in the official metric, both relative to the unsteered prediction ( Tab. 2 ); color: method category, marker: method. The direct edit, DDNM and DiffPIR sit at 100% with smaller official gains; every other method removes at most 84% of the target error (DNO on GDP-HMM).
Variant
DD
MD
DiT
GDP
Local
No price ( μ→0 )
3.3
4.5
4.2
7.7
15.0
No shape term ( λ=0 )
2.9
4.8
4.5
–
14.2
No price, no shape term
1.7
3.5
4.2
7.7
11.9
Noise lever only
1.1
5.4
5.1
11.0
13.1
Context lever only
2.6
−0.1
2.9
1.3
6.0
DRG (full)
3.2
5.0
4.9
11.0
14.6
Table 3: Ablation results on key designs of DRG. Official metric gain (%) on test sets when removing the price, the shape term, or both (top), or restricting DRG’s structure-wise joint solver to a single lever (bottom). On GDP-HMM the validated λ is 0 , so there is no shape term to remove and the third row equals the first.
Figure 4: Ablation on DDIM steps and steering steps. (a) Official error of the unsteered predictors against the number of DDIM steps, relative to 8 steps (positive: worse); two steps are off the scale on four settings (triangles, values printed). (b) Gain in the official metric when DRG corrects the steps t=s,…,0 , for every start step s ; hollow markers: not significantly different from s=3 ; the curves of MD-Dose and DoseDiT nearly coincide.
Figure 5: DRG leans on the lever that works. Points: share of the target residual removed at each steering step, 1−∑k∣rk∣ after the step’s correction over ∑k∣rk∣ before, by the noise or context lever alone, and DRG, mean over the test plans. Bars: DRG’s split of the linearized metric change, ∥GNα∥/(∥GNα∥+∥GCβ∥) for the noise lever, mean over the cases.
Figure 6: Qualitative results. Axial slices from (a) OpenKBP and (b) GDP-HMM test cases with DoseDiff, comparing unsteered predictions, the top baseline from each category (DiffPIR, Π GDM, DNO), and DRG (top: dose; bottom: absolute error saturated at 8 Gy). DRG achieves the lowest error both inside and outside the steered structures.
Appendix figures & tables6 assets
Supplementary material from the paper’s appendix.
Appendix
Figure 7: Architecture of DoseDiT. Two 12-layer ViT encoders read the CT and the 20 structure channels (SDM); their layers 2, 5, 8 and 11 are added to the dose tokens after the first four DiT blocks, before a fusion transformer and twelve DiT blocks with U-ViT skip connections. Right: one DiT block, with RMSNorm, attention with rotary position embeddings, a SwiGLU feed-forward layer and adaLN-Zero modulation by the timestep embedding.
OpenKBP
GDP-HMM
Local
DoseDiff
MD-Dose
DoseDiT
DoseDiff
DoseDiff
γ
3
0.1
0.003
0.1
0.3
λ
0.1
0.03
0.1
0
1
Appendix
Table 4: The two hyperparameters of DRG chosen on validation data, per model: γ , which sets σβ=0.03γ , and λ .
Method
Param.
DD
MD
DiT
GDP
Local
DiffPIR
ζ
0.1
0.3
1
1
1
DPS
ζ
1
1
1
3
0.3
TMPD
σy
0.1
0.1
0.3
0.3
0.3
TFG
μˉ
0.25
0.0625
0.25
0
0.0625
ρˉ
0.25
0.25
0.25
1
0.0625
DAPS
lr
3⋅10−6
3⋅10−6
3⋅10−6
3⋅10−6
3⋅10−6
Appendix
Table 5: Hyperparameters of the comparison methods: the value chosen on validation cases per setting (DD, MD, DiT, GDP, Local as in Tab. 2 ).
Target error
Official metric
Method
DD
MD
DiT
GDP
Local
DD
MD
DiT
GDP
Local
Unsteered
1.417
2.494
1.415
1.039
0.555
2.707
4.308
2.756
2.508
0.710
Clean-space correction and alternating inference
Direct edit
0.000
0.000
0.000
0.000
0.000
2.685
4.332
2.728
2.419
0.688
DDNM [ 56 ]
0.001
0.002
0.001
0.000
0.000
2.680
4.322
2.684
2.284
0.694
DiffPIR [ 65 ]
0.001
0.003
0.001
0.000
0.000
2.677
4.321
2.683
2.263
0.693
Appendix
Table 6: The errors of Tab. 2 in absolute values. Cohort-mean errors on the test sets in Gy, lower is better: the target error, the official metric, the DVH score and the outside error ( Sec. 4.1 ) of the unsteered prediction and of every method, on the settings of Tab. 2 , whose cells are 100(1−e/eunsteered) of these values before rounding. Best per column in bold, none in the target-error block because direct edit enforces target error to 0.
Figure 8: Official gain against compute. Gain in the official metric ( Tab. 2 ) against the number of network function evaluations (NFE) per case, on a log scale; color: method category, marker: method, as in Fig. 3 ; cross: unsteered prediction. One evaluation is a network pass over all slices of a case; a pass over part of the slices counts pro rata and a backward pass as two.
Figure 9: Robustness to counterfactual targets on OpenKBP with DoseDiff. One OAR’s mean-dose target is lowered by r (marker size; r=0 : the clinical targets of Tab. 2 , on the cases with that OAR), every other target is clinical; panel titles: the lowered OAR and its number of organs. Horizontal: reduction of the target error, measured against the lowered target (higher is better). Vertical: gain in the official metric (first and third rows) and in the outside error (second and fourth rows), both measured against the original clinical dose: they show how far a method moves from the original plan. All values are relative to the unsteered prediction, in %.
Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.
Voxel-wise dose prediction is a critical yet challenging task in practical radiotherapy (RT) planning, as bespoke models trained from scratch often struggle to generalize across diverse clinical settings. Meanwhile, generative models trained on billion-scale datasets from vision domains have achieved impressive performance. Herein, we propose DiffKT3D, a unified Any2Any 3D diffusion framework that leverages prior knowledge from pretrained video diffusion models for efficient and clinically meaningful dose prediction. To enable flexible conditioning across multiple clinical modalities (CT, anatomical structures, body, beam settings, etc.), we introduce an Any2Any conditional paradigm utilizing modality-specific embeddings without cross-attention overhead. Further, we design a novel reinforcement learning (RL) post-training mechanism guided by a clinically-informed Scorecard explicitly tailored to institutional treatment preferences. Compared with winner of GDP-HMM challenge, DiffKT3D sets a new state-of-the-art in dose prediction by reducing voxel-level MAE from 2.07 to 1.93. In addition, DiffKT3D achieves superior image quality and preference match. These results demonstrate that transferring diffusion priors via modality-aware conditioning and clinically aligned RL post-training can provide a robust and generalizable solution for RT planning across various clinical scenarios.
Yuhan Wang, Zihan Li, Han Liu +7
1UC Santa Cruz · 2Siemens Healthineers · University of Washington
Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage (D95), though statistical analysis revealed a marginal reduction in target homogeneity (p<0.001) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing (p<0.001). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in 11 out of 14 Moderate Hypofraction Arm plans and 9 out of 12 Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.