cs.CVNov 25, 2026

Where Does Free-Text 3D Grounding Fail? An Error Analysis of Report-Sentence Segmentation in Chest CT

Authors: Abdullah Arif Sheikh, Kamalaker Dadi, Raju S. Bapi

Organizations: Department of Artificial Intelligence, Vidya Jyothi Institute of Technology, Hyderabad, India · IHub-Data, International Institute of Information Technology, Hyderabad, India

Abstract

Free-text 3D grounding, segmenting in a CT volume the region described by one sentence of the radiology report, could link reports to images at scale, but it is unclear where current models fail. We analyse the publicly released VoxTell model on all 381 findings of the 200-scan ReXGroundingCT validation set, where it grounds 53.5% of findings. Its failures are rarely about which lesion or side is meant. No miss lies on the side opposite to the one named, and findings are almost never confused with one another. Instead, predictions are too large, land on a neighbouring lesion on the correct side, or are missing for small findings, and diffuse findings are rarely grounded. Removing location words halves performance, to the level of label-only prompting, and anatomical rules derived from the sentence never improve the full-sentence output. The same pattern holds on the hidden 300-scan test set. Further progress therefore depends on extent estimation and small-lesion sensitivity rather than on anatomical post-processing.

Figures & tables

Appendix figures & tables2 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 14, 2026

Decouple and Reason: Anatomically Guided Two-Stage Voxel-Level Grounding of Free-Text Findings in 3D Chest CT

Automatic voxel-level grounding of free-text findings in 3D chest Computed Tomography (CT) is critical for clinical interpretability. However, this task remains highly challenging due to the intricate spatial complexity of large 3D volumes and the heterogeneity of free-text findings. Existing end-to-end approaches often struggle to simultaneously learn the localized feature representations required for accurate 3D segmentation and the complex semantic understanding needed for text alignment, leading to suboptimal grounding performance. To overcome this fundamental limitation, we propose a novel decoupled framework that disentangles the problem into two specialized stages: (1) class-agnostic lesion segmentation and (2) text-volume reasoning. This structural separation allows the model to first extract candidate sub-volumes by localizing potential abnormalities. Subsequently, intensive cross-modal reasoning is performed to align these localized sub-volumes with free-text medical findings. To resolve the spatial ambiguities inherent in local regions, the reasoning module is augmented with explicit anatomical guidance, utilizing relative spatial coordinates and lung lobe priors. Evaluated on the ReXGroundingCT benchmark, our method achieves state-of-the-art performance in overall grounding quality on the official leaderboard. These results demonstrate that decoupling detection from reasoning is a highly effective paradigm for handling the complexity of 3D medical visual grounding. Our code is publicly available at https://github.com/khuhm/DAGG.
Nov 18, 2026

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.
Nov 23, 2026

CTLink: A Text-Prompted Segmentation Model for Linking Radiology Report Findings to 3D Chest CT Scans

Radiology reports describe findings in text only, without visually marking them on the scan, so readers cannot directly see which abnormality each reported finding refers to. We introduce CTLink, a text-prompted 3D segmentation model that segments findings described in a chest CT report. CTLink was trained on 4123 noncontrast chest CT scans with 9547 segmented report findings, including ReXGroundingCTv2, a newly annotated dataset of 1134 scans and 1895 findings with every instance of each finding segmented. On the 200 ReXGroundingCT validation scans, CTLink achieved a hit rate of 0.816, an instance F1 score of 0.456, and a mean Dice score of 0.400, compared with 0.533, 0.175, and 0.234 for VoxTell, a publicly available text-prompted segmentation model (P < .001 for all). On the test set of the MICCAI 2026 ReXGrounding challenge, an ensemble of seven CTLink models achieved the highest hit rate (0.782) and instance F1 score (0.386) of all 48 participating teams. On 50 test scans segmented twice by independent radiologists, CTLink matched or exceeded inter-rater agreement. Diffuse non-focal findings remained the main limitation, partly because their extent is outlined inconsistently even between radiologists. The CTLink model weights are available at https://huggingface.co/rajpurkarlab/CTLink, and the dataset at https://huggingface.co/datasets/rajpurkarlab/ReXGroundingCT.