Generating semantically controllable 3D CT volumes from radiology reports requires more than a rich text encoder, it requires vision-language alignment grounded in volumetric space. Existing Text-to-CT approaches condition generation on encoders pretrained with language only or 2D vision-language objectives, providing conditioning signals that are linguistically expressive but volumetrically blind. We argue this is a structural limitation: the quality of 3D vision-language alignment, not the richness of the text encoder, is the primary bottleneck for semantic controllability in volumetric diffusion models. To address this, we propose a generation-oriented 3D-CLIP encoder trained with structured hard negatives that operate exclusively at the text level. This design increases contrastive difficulty without any additional 3D memory cost, overcoming the small-batch constraints inherent to volumetric encoders. The resulting encoder conditions a fully end-to-end latent diffusion model that operates directly in 3D latent space, eliminating the spatial artifacts and cross-slice inconsistencies introduced by super-resolution pipelines. Through systematic ablations, we establish a clear empirical link between grounding quality and downstream generative controllability. Evaluated on CT-RATE across 18 pathological conditions, our method achieves state-of-the-art performance on both image fidelity and factual correctness, while requiring less inference time and GPU memory than all competing methods. Code is at https://github.com/danielemolino/Text2CT.
Generative models for volumetric medical images have found many applications in medical imaging, ranging from data augmentation to serving as priors for inverse problems. For these applications, generating high-resolution 3D images with strong controllability is essential but remains highly challenging. Existing approaches typically control generation either through radiology reports used as text prompts or through full image segmentation. While text-based prompting is flexible, it provides limited spatial control over the location, shape, and boundary of abnormalities. In contrast, segmentation-based methods receive precise spatial guidance but are restrictive in requiring full-organ annotations. In this work, we propose a flexible multimodal framework for controllable volumetric image generation that supports input from radiology reports and segmentation prompts (both optional). Our approach allows users to provide segmentation of a specific anatomy or abnormality without requiring full-organ annotations. The semantic meaning of the segmentation mask is specified through an accompanying text description, resulting in a highly flexible and scalable conditioning mechanism. We develop a memory-efficient architecture based on a modified diffusion transformer that jointly processes image and segmentation tokens. The model further incorporates gated attention to effectively attend to long radiology reports. Experiments demonstrate that our method achieves state-of-the-art perceptual and semantic scores (e.g., 24% relative improvement in mean FID), generates high-resolution anatomically consistent CT volumes, and improves data efficiency when used for data augmentation. Radiologists' evaluation further confirms strong alignment between generated and real medical images.
Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning. We present CONFLUX, a latent diffusion model for chest computed tomography (CT): a 3D variational autoencoder compresses each volume, and a rectified-flow transformer generates in the latent space. Generation is conditioned on structured radiological metadata (18 abnormality findings, sex, age, and reconstruction kernel) through adaptive layer normalization. The model leads strong volumetric baselines on tri-planar Frechet distance (FID 32.3 vs. 74.6 for MAISI) while exposing direct control over clinical attributes. To strengthen that control we add an online reinforcement-learning post-training stage (group-relative policy optimization) that rewards how reliably a classifier recovers the requested findings from each generated volume. Judged by a separate, independent classifier, post-training removes 47% of the shortfall relative to real-scan reliability. We release the model and a ~200k synthetic chest-CT dataset with conditioning metadata spanning a wide variety of clinical findings.
Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge +1
Modern 3D medical vision-language models (VLMs) can generate fluent radiology-style text while exhibit critically low pathology detection and output diversity, collapsing to generic templates that under-report rare yet critical findings. We identify this failure mode as Template Collapse. This failure stems from the unique constraints of 3D medical imaging, e.g., limited data, severe label imbalance, and weak signals from volumetric encoders. Under these constraints, text-generation objectives encourage shortcut learning and fluent but weakly grounded reports. We systematically diagnose the Template Collapse through clinical fidelity, output diversity, normal-template bias, and rare-finding survival. To mitigate it, we propose CLarGen, a decoupled framework that separates what to say (clinical detection) from how to say it (language synthesis). CLarGen uses (i) a Latent Query Transformer for multi-label pathology detection, (ii) pathology-guided retrieval for clinically matched exemplars, and (iii) a medical language model to synthesize the final report from detected findings and retrieved context. Across state-of-the-art 3D CT report generation baselines, CLarGen mitigates Template Collapse and substantially improves clinical accuracy (macro-F1 0.487 vs. 0.189; CRG 0.472 vs. 0.368) while maintaining fluent reporting. Our results suggest that explicit, measurable clinical grounding is essential for template-collapse-resistant 3D CT report generation. Code is available at https://github.com/ai-med/CLarGen.