cs.CVOct 23, 2025

ALICE-LRI: A General Method for Lossless Range Image Generation for Spinning LiDAR Sensors without Calibration Metadata

Authors: Samuel Soutullo, Miguel Yermo, David L. Vilariño, Óscar G. Lorenzo, José C. Cabaleiro, Francisco F. Rivera

Organizations: Centro Singular de Investigación en Tecnoloxías Intelixentes (CiTIUS), Rúa de Jenaro de la Fuente Domínguez, Santiago de Compostela, 15782, A Coruña, Spain · Departamento de Electrónica e Computación, Universidade de Santiago de Compostela, Rúa Lope Gómez de Marzoa, Santiago de Compostela, 15782, A Coruña, Spain

Abstract

3D LiDAR sensors are widely used in autonomous navigation, environmental monitoring, and precision mapping. Their point clouds are often projected into 2D range images for efficient processing, but conventional projection methods can lose points because of geometric inconsistencies. We present ALICE-LRI (Automatic LiDAR Intrinsic Calibration Estimation for Lossless Range Images), a metadata-free method for lossless range-image generation from calibrated spinning multi-beam LiDAR point clouds. It requires neither factory calibration files, packet-level data, nor beam identifiers, and targets operating regimes where scanlines contain enough returns for reliable parameter estimation. The method estimates the intrinsic calibration parameters relevant to projection, including beam configuration, angular distributions, and per-beam geometric corrections. Evaluation on the complete KITTI and DurLAR datasets yielded zero lost points across all point clouds. Reconstruction deviations remain below manufacturer-reported range-performance specifications, while the method runs in real time. A compression case study also shows improved reconstruction quality and a better quality-compression trade-off for a downstream application. These results enable range-image-based LiDAR processing in applications that require high measurement fidelity and preservation of acquired geometric information.

Figures & tables

Explore similar work

Jun 12, 2026

LV-Calib: LiDAR-Camera Extrinsic Calibration with Boundary-Response Modeling

We present LV-Calib, a calibration framework for LiDAR-camera extrinsic estimation and LiDAR boundary-response calibration using a printable planar target. The target serves as a shared observation carrier: visual fiducials provide indexed image measurements, while circular reflectivity boundaries provide LiDAR-observable structural feature points. Instead of directly fitting boundary points as ideal geometric contours, LV-Calib automatically crops background points, estimates the target plane, and iteratively refines accurate LiDAR-side 3-D feature points from intensity and geometric constraints. The refinement explicitly handles the broadened and distorted transition band induced by finite beam footprint and mixed-intensity returns around black-white reflectivity discontinuities. Given these refined LiDAR features, we formulate a weighted reprojection-consistent extrinsic optimization with LiDAR feature alignment, where image observations are kept in the reprojection domain and LiDAR feature residuals are weighted by refinement confidence. Finally, using the estimated extrinsic and the extracted transition band, LV-Calib calibrates the LiDAR boundary response by estimating pitch-yaw-range residual statistics of boundary-overlap samples. Experiments on printed-board calibration data demonstrate sub-pixel reprojection accuracy, millimeter-level LiDAR feature consistency, and improved odometry performance. Code and calibration data will be released for reproducible evaluation.
Sep 7, 2026

P2^2Calib: Utilizing Pattern Priors for LiDAR-Camera Extrinsic Calibration

Target-based LiDAR-camera extrinsic calibration is a prerequisite for multi-sensor fusion in robotics. However, in the widely adopted four-hole pipeline, \rt{calibration accuracy is limited by hole-center extraction in the LiDAR side, where sparse angular coverage and mixed-pixel returns displace the estimated centers}. This paper presents P2^2Calib, which exploits pattern priors, geometric constraints specified by the CAD model of the target board, to improve calibration accuracy. First, we incorporate the known hole radius as a fitting constraint to prevent center estimates from degrading under sparse angular coverage. Building on the improved hole estimates, we further enforce the rigid rectangular layout of the four holes as a global consistency constraint to correct residual errors across holes. Both priors are integrated into an \rt{interactive tool that runs the pipeline from target detection to the final extrinsic}. Experiments on simulated and real datasets show that P2^2Calib reduces the joint registration residual by 90% and 82% and the held-out reprojection error by 96% and 77% over the baseline. \rt{We will release the code and data\codelink{} to facilitate future research.
Oct 27, 2026

Generalizable Target-Less Joint Intrinsic-Extrinsic Camera-LiDAR Calibration using Deep Pixel-Point Correspondences

Accurate camera-LiDAR calibration is an essential prerequisite for robust multi-modal perception in robotics. Recent target-less methods based on learned pixel-point correspondences achieve high extrinsic calibration accuracy and generalize across environments. However, they operate on rectified images with known camera intrinsics, restricting their applicability to systems whose cameras have already been individually calibrated. We present a fully automatic, target-less framework that jointly estimates camera intrinsics, radial-tangential distortion, and camera-LiDAR extrinsics from raw images and LiDAR scans. Our method generalizes deep correspondence-based calibration from rectified images to raw cameras through intrinsic- and distortion-aware correspondence learning via synthetic augmentations. During calibration, we iteratively couple correspondence prediction and nonlinear optimization to jointly refine the camera parameters and relative sensor transformation. We evaluate our approach on an unseen camera-LiDAR configuration from the KITTI dataset and on three real robotic platforms in a zero-shot manner. The results demonstrate that joint calibration with our generalized pixel-point correspondence network improves extrinsic accuracy over correspondence-based methods using pre-calibrated cameras, while additionally recovering accurate intrinsics.