cs.LGDate pending

A Dataset and Benchmarks for Atrial Fibrillation Detection from Electrocardiograms of Intensive Care Unit Patients

Authors: Sarah NassarNooshin MaghsoodiSophia ManninaShamel AddasStephanie SibleyGabor FichtingerDavid PichoraDavid Maslove+2 more

Abstract

Objective: Atrial fibrillation (AF) is the most common cardiac arrhythmia experienced by intensive care unit (ICU) patients and can cause adverse health effects. In this study, we publish a labelled ICU dataset and benchmarks for AF detection. Methods: We compared machine learning models across three data-driven artificial intelligence (AI) approaches: feature-based classifiers, deep learning (DL), and ECG foundation models (FMs). This comparison addresses a critical gap in the literature and aims to pinpoint which AI approach is best for accurate AF detection. Electrocardiograms (ECGs) from a Canadian ICU and the 2021 PhysioNet/Computing in Cardiology Challenge were used to conduct the experiments. Multiple training configurations were tested, ranging from zero-shot inference to transfer learning. Results: On average and across both datasets, ECG FMs performed best, followed by DL, then feature-based classifiers. The model that achieved the top F1 score on our ICU test set was ECG-FM through a transfer learning strategy (F1=0.89). Conclusion: This study demonstrates promising potential for using AI to build an automatic patient monitoring system. Significance: By publishing our labelled ICU dataset (LinkToBeAdded) and performance benchmarks, this work enables the research community to continue advancing the state-of-the-art in AF detection in the ICU. https://physionet.org/content/kingston-icu-af/

Explore similar work

Aug 4, 2026cs.AI

FOUND-AF: Benchmarking ECG Foundation Models for Atrial Fibrillation Detection

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and is associated with increased risks of stroke, heart failure, and mortality. Recent ECG foundation models offer transferable representations for automated AF detection. However, their relative effectiveness remains unclear because existing studies use different datasets, preprocessing procedures, classifiers, and validation protocols. This study presents FOUND-AF, a unified, leakage-controlled, and deployment-oriented benchmarking framework that evaluates the quality of pretrained ECG representations under identical experimental conditions. Nine publicly available foundation models from five families, including HuBERT-ECG, CLEF, ST-MEM, ECG-JEPA, and ECGFounder, were evaluated across four heterogeneous ECG datasets, namely AFDB, CinC2017, CPSC2021, and LTAFDB. All models were used as frozen feature extractors with standardized preprocessing, model-native resampling, a fixed XGBoost classifier, and recording-level grouped cross-validation. The evaluation included classification metrics, receiver operating characteristic analysis, paired recording-level bootstrap comparisons with Holm correction, embedding-space visualization, and computational efficiency profiling. The ECGFounder model consistently achieved the strongest overall performance across datasets while offering a favorable trade-off between accuracy, model size, inference time, and memory usage. FOUND-AF therefore provides a reproducible framework for selecting ECG foundation models and demonstrates that compact, clinically pretrained encoders can support robust and computationally efficient AF detection across heterogeneous acquisition settings.
Amirhossein Taleshinosrati, Yangyang Wang, Atitaya Phoemsuk +5
Jun 9, 2026cs.LG

Pre-AF 13: An Interpretable Atrial Fibrillation Risk Score Mined from Discharge Reports

Background. Atrial fibrillation (AF) is the most prevalent cardiac arrhythmia and a major determinant of prognosis. Established AF risk scores rely on factors (older age, hypertension) nearly ubiquitous among patients with cardiovascular disease (CVD), offering limited stratification in this high-risk group. Most target long-term (5-10 year) rather than medium-term prediction. We developed interpretable ML models predicting AF risk over a 24-month and entire follow-up horizon in CVD patients using routinely collected hospital data. Methods. Single-center retrospective study of electronic health records from the National Research Cardiology Center (Russia) for patients aged >=18 with CVD but without pre-existing AF, hospitalized more than once between January 2012 and May 2019. A custom NLP pipeline transformed unstructured discharge reports into 73 structured features, combining a rule-based parser with transformer-based NER. Using LightAutoML we built a full model (73 features), a simple model (reduced subset), and a linear model for a bedside risk score. Performance was assessed by ROC AUC, compared with CHARGE-AF, C2HEST, MHS, and HAVOC, and interpreted via SHAP. Results. Of 80,576 records from 45,000 patients, 17,562 met inclusion criteria; 1,438 (8.19%) developed AF. The full model reached ROC AUC 0.735 (24-month) and 0.696 (entire follow-up); the simple model was nearly identical (0.725, 0.696). All non-linear models outperformed the four clinical risk scores (ROC AUC 0.53-0.64). The simple model uses 13 features and is named Pre-AF 13. SHAP identified age and left atrial volume as dominant predictors. A linear risk score (Pre-AF 9) stratified observed 24-month AF incidence from ~7% to 36%. Conclusion. Interpretable ML models built from routinely collected EHR data identify high-AF-risk CVD patients, outperforming established clinical risk scores.
Olga Shakhmatova, Dmitrii Kriukov, Daniil Larionov +10
May 25, 2026cs.AI

A Signal-Language Foundation Model for Broad-Spectrum Cardiovascular Assessment from Routine Electrocardiography

Electrocardiography (ECG) is central to cardiovascular care, but conventional AI models are often restricted to common arrhythmias and may generalize poorly across populations or clinically subtle diseases. We developed ECG Contrastive Language-Image Pre-training (ECGCLIP), a signal-language contrastive learning framework that aligns ECG waveforms with expert diagnostic reports. ECGCLIP was pre-trained on 2,837,962 ECG studies from 1,324,856 patients and evaluated on a held-out internal test set plus nine independent external cohorts comprising about 1.5 million ECGs. Evaluation covered 89 downstream tasks, including 45 ECG diagnoses, 39 echocardiographic targets, and 5 rare cardiac diseases, using PRAUC as the primary metric. ECGCLIP consistently improved performance over random initialization and Merl-R18 baselines. On the internal test set, ECGCLIP-R34 achieved strong performance for atrial fibrillation (PRAUC 0.900) and ST-segment elevation myocardial infarction (PRAUC 0.383), with robust generalization across all external cohorts. It also improved low-prevalence and diagnostically elusive diseases, including Ebstein anomaly, constrictive pericarditis, dextrocardia, and cardiac amyloidosis, with internal PRAUC values of 0.253, 0.175, 0.121, and 0.201, respectively. ECGCLIP was data efficient, matching or exceeding full-dataset baseline performance with only 10% of training data. Feature visualization and saliency analysis suggested clinically meaningful representations aligned with established electrocardiographic criteria. These findings indicate that large-scale ECG-report contrastive pre-training can expand routine ECG interpretation beyond common arrhythmias toward broad cardiovascular assessment and opportunistic screening of echocardiographic and rare conditions.