cs.MMJan 5, 2026

ELF: A Family of Encoder-Free ECG-Language Models

Authors: William HanTony ChenChaojing DuanXiaoyu SongYihang YaoYuzhe YangMichael A. RosenbergEmerson Liu+1 more

Abstract

ECG-Language Models (ELMs) extend recent advances in Multimodal Large Language Models (MLLMs) to automated ECG interpretation. However, most existing ELMs inherit Vision-Language Model (VLM) design choices and rely on pretrained ECG encoders, introducing substantial architectural and training complexity. Inspired by encoder-free VLMs, we introduce ELF, a family of three encoder-free ELMs that remain competitive with, and often outperform, prior state-of-the-art ELMs across two datasets despite substantially simpler architectures and training pipelines. All code and data are available at github.com/ELM-Research/ECG-Language-Models.

Explore similar work

Aug 31, 2026cs.CL

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.
Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
May 25, 2026cs.AI

A Signal-Language Foundation Model for Broad-Spectrum Cardiovascular Assessment from Routine Electrocardiography

Electrocardiography (ECG) is central to cardiovascular care, but conventional AI models are often restricted to common arrhythmias and may generalize poorly across populations or clinically subtle diseases. We developed ECG Contrastive Language-Image Pre-training (ECGCLIP), a signal-language contrastive learning framework that aligns ECG waveforms with expert diagnostic reports. ECGCLIP was pre-trained on 2,837,962 ECG studies from 1,324,856 patients and evaluated on a held-out internal test set plus nine independent external cohorts comprising about 1.5 million ECGs. Evaluation covered 89 downstream tasks, including 45 ECG diagnoses, 39 echocardiographic targets, and 5 rare cardiac diseases, using PRAUC as the primary metric. ECGCLIP consistently improved performance over random initialization and Merl-R18 baselines. On the internal test set, ECGCLIP-R34 achieved strong performance for atrial fibrillation (PRAUC 0.900) and ST-segment elevation myocardial infarction (PRAUC 0.383), with robust generalization across all external cohorts. It also improved low-prevalence and diagnostically elusive diseases, including Ebstein anomaly, constrictive pericarditis, dextrocardia, and cardiac amyloidosis, with internal PRAUC values of 0.253, 0.175, 0.121, and 0.201, respectively. ECGCLIP was data efficient, matching or exceeding full-dataset baseline performance with only 10% of training data. Feature visualization and saliency analysis suggested clinically meaningful representations aligned with established electrocardiographic criteria. These findings indicate that large-scale ECG-report contrastive pre-training can expand routine ECG interpretation beyond common arrhythmias toward broad cardiovascular assessment and opportunistic screening of echocardiographic and rare conditions.
Ziqing Yu, Yuhui Tao, Jiayu Huo +19
May 17, 2026cs.LG

How Do Electrocardiogram Models Scale?

While scaling laws have established a fundamental framework for foundation models in natural language processing, their applicability to electrocardiogram (ECG) models remains poorly characterized. Indeed, recent studies do not always yield consistent downstream gains as one increases the model size or pre-training dataset size of ECG models, leaving the exact roles of architectural inductive biases, pre-training paradigms, and expected improvements with size largely unanswered. In this work, we systematically investigate neural and loss-to-loss scaling laws within the ECG domain. By pre-training over 120120 models (ranging from 2020K to 200200M parameters) on the large-scale CODE dataset (2.32.3M records), we decouple the effects of model architecture (ResNet vs. Transformer) and pre-training paradigm, namely supervised learning (SL) versus self-supervised learning (SSL). We found that (i) SL models are data-bottlenecked in-distribution, whereas SSL models scale robustly across both model and data sizes; (ii) for out-of-distribution (OOD) generalization, ResNets are 1.31.3 to 2.52.5 times more parameter-efficient than Transformers, while SSL is up to 1616 times more data-efficient and achieves up to 7.67.6 times higher transfer efficiency than SL on unseen clinical tasks; (iii) across the observed scales, ResNet-based models generally achieve the lowest OOD loss, with SSL dominating on unseen clinical tasks and self-supervised Transformers overtaking at very large model sizes. Our results suggest that the path to effective ECG foundation models lies in the strategic alignment of architecture and paradigm rather than brute-force scaling.
Jiawei Li, Fabio Bonassi, Ming Jin +4