Learned Finite Element-based Regularization of the Inverse Problem in Electrocardiographic Imaging
Authors: Manuel Haas, Thomas Grandits, Thomas Pinetz, Thomas Beiert, Simone Pezzuto, Alexander Effland
Organizations: Institute for Applied Mathematics, University of Bonn, Germany · Department of Mathematics and Scientific Computing, University of Graz, Austria · Institute of Artificial Intelligence, Medical University of Vienna, Austria · Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Germany · Department of Mathematics, University of Trento, Italy
Electrocardiographic imaging (ECGI) seeks to reconstruct cardiac electrical activity from body-surface potentials noninvasively. However, the associated inverse problem is severely ill-posed and requires robust regularization. While classical approaches primarily employ spatial smoothing, the temporal structure of cardiac dynamics remains underexploited despite its physiological relevance. We introduce a space-time regularization framework that couples spatial regularization with a learned temporal Fields-of-Experts (FoE) prior to capture complex spatiotemporal activation patterns. We derive a finite element discretization on unstructured cardiac surface meshes, prove Mosco-convergence, and develop a scalable optimization algorithm capable of handling the FoE term. Numerical experiments on synthetic epicardial data demonstrate improved denoising and inverse reconstructions compared to handcrafted spatiotemporal methods, yielding solutions that are both robust to noise and physiologically plausible.
Figures & tables
Figure 1: Illustration of the discretized cross-correlation computation of the matrix D(t) evaluated at the nodes ts of the uniform mesh with kernel defined in T=[t−2,t2] . The integrals of the products of the overlapping hat functions give the matrix entries.
Figure 2: Lifting of the x point in a simplex at a boundary element J⊂Uh to the true domain by Hh(x)∈Je⊂Ω0 in R2 . We compute the linear projection y of x onto the boundary ThΓ , take the closest-point projection p(y) on Γ , and map x towards p(y) to compute Hh(x) .
Fréchet derivative
Discretization
DG(u,z)(x,t)=(u−z)(x,t)
∇Gh(u,z)=u−z
DG(u,z)(x,t)=A∗A[u](x,t)−A∗[z](x,t)
∇Gh(u,z)=M−1A⊤(Au−z)
DRθ(u)(x,t)=λθL∗Φ(L[u])(x,t)
∇Rθ,h(u)=λθL∗Φ(Lu)
Table 1: Fréchet derivatives and their discrete approximations employed in optimization.
Algorithm 1 Accelerated gradient descent with objective-based restart
Figure 3: Three-dimensional torso-heart model with three stimulation sites on the epicardium (apex, left and right ventricle) and human torso with 128 electrodes.
Figure 4: Extracellular potential ve on the myocardium for the 2D and 3D dataset at multiple time steps with scar tissue and normalized to [0,1] . The 2D data is visualized in a spacetime plot on the epicardium. 3D potentials are visualized restricted to the epicardium. Reduced conductivity in the scar region deforms the characteristic potentials and slows propagation.
Parameter
Value
Parameter
Value
Vrest
−85mV
Vdep
30mV
Vth
−55mV
gmax
1.4×10−3(2D)3.132×10−4(3D)
σi,l
3S/m
λLT [ 28 ]
[2.16,2.84]
ε [ 28 ]
[0.58,0.93]
α [ 28 ]
1
Cm [ 27 ]
1μF/cm2
β [ 27 ]
800cm−1(2D)179cm−1(3D)
Idur
1.2μA/cm2
Imax
100ms
Table 2: Model parameters and sampling ranges used for the generation of the synthetic datasets. Parameters are identical for the 2D and 3D models unless specified separately. Parameters are drawn uniformly at random from the indicated intervals.
Figure 5: Learned kernel functions (kh,i)i=1NC for NC=16 of the FoE approaches by denoising.
Figure 6: Denoising reconstructions of the 2D model and L2 -errors of multiple regularization approaches for an observation with a noise level of κ=0.2 applied to the ground truth, visualized in a space-time plot.
Figure 7: Denoising reconstructions of the 3D model and L2 -errors of multiple regularization approaches for an observation with a noise level of κ=0.2 applied to the ground truth, visualized on the epicardium for one timestep and as a plot over time at a randomly chosen point on the epicardium.
Table 3: Mean L2 -errors and corresponding regularization parameters for denoising reconstructions of different noise levels with standard deviation κ∈(0.05,0.1,0.2) for 2D and κ=0.2 for 3D.
Figure 8: Inverse problem reconstructions of the 2D model and L2 -errors of multiple regularization approaches with SNR of 30 dB by applying Gaussian noise to the observations, visualized in a space-time plot.
Figure 9: Inverse problem reconstructions of the 3D model and L2 -errors of multiple regularization approaches with an SNR of 30 dB by applying Gaussian noise to the observations, visualized on the epicardium for one time step and as a plot over time at a randomly chosen point on the epicardium.
Table 4: Mean L2 -errors and corresponding regularization parameters for inverse problem reconstructions at SNR (30,40,50) dB for 2D and SNR 30 dB for 3D.
Department of Computer Science and Engineering, Indian Institute of Technology Roorkee, Roorkee 247667, India · Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee 247667, India