Location-Aware Pretraining for Medical Difference Visual Question Answering
Organizations: Department of Electrical and Computer Engineering, Carnegie Mellon University, Kigali, Rwanda · University of Melbourne, Melbourne, Australia.
Abstract
Differential medical VQA models compare multiple images to identify clinically meaningful changes and rely on vision encoders to capture fine-grained visual differences that reflect radiologists' comparative diagnostic workflows. However, vision encoders trained using standard contrastive or classification objectives often fail to capture the subtle variations needed to distinguish true disease progression from acquisition-related variability. To address this limitation, we introduce a location-aware pretraining framework that incorporates automatic referring expressions (AREF), grounded captioning (GCAP), and conditional automatic referring expressions (CAREF). These tasks promote the learning of fine-grained, spatially grounded visual representations. When integrated with a language model, our approach achieves state-of-the-art performance on medical difference VQA by accurately identifying and reasoning about clinically relevant changes in chest X-ray images.
Figures & tables
| BLEU-4 | METEOR | ROUGE-L | CIDEr |
|---|---|---|---|
| 0.476 | 0.501 | 0.593 | 1.201 |
| Method | BLEU-4 | METEOR | ROUGE-L | CIDEr | BertScore |
|---|---|---|---|---|---|
| Location Aware Pretraining (Ours) | 0.594 | 0.425 | 0.747 | 2.997 | 0.972 |
| Global Contrastive Pretraining | 0.291 | 0.300 | 0.407 | 0.550 | 0.850 |
| Regional Contrastive Pretraining | 0.360 | 0.338 | 0.465 | 0.635 | 0.956 |
| BLIP-2 ( Li et al., 2023b ) | 0.375 | 0.350 | 0.545 | 0.801 | 0.960 |
| CapPa ( Tschannen et al., 2023 ) | 0.350 | 0.327 | 0.529 | 0.675 | 0.948 |
| RG-AG ( Serra et al., 2025 ) | 0.551 | 0.384 | 0.668 | 2.198 | 0.965 |
| Case I | Case II | Case III |
| Reference Main | Reference Main | Reference Main |
| Q : What has changed compared to the reference image? | Q : What has changed compared to the reference image? | Q : What has changed compared to the reference image? |
| GT : the main image has additional findings of lung opacity , and atelectasis than the reference image. | GT : the main image has an additional finding of atelectasis than the reference image. | GT : the main image has additional findings of cardiomegaly, edema , atelectasis , and pleural effusion than the reference image. the main image is missing the findings of lung opacity , and pneumonia than the reference image. |
| Ours : the main image has additional findings of lung opacity , and atelectasis than the reference image. | Ours : the main image has an additional finding of atelectasis than the reference image. | Ours : the main image has additional findings of atelectasis , and pleural effusion than the reference image. the main image is missing the findings of lung opacity , and pneumonia than the reference image. |
| ReAL : the main image has additional findings of lung opacity , and atelectasis than the reference image. | ReAL : the main image has additional findings of pleural effusion , and atelectasis than the reference image. | ReAL : the main image has additional findings of atelectasis , and lung opacity than the reference image. |
| AREF | GCAP | CAREF | CAP | BLEU-4 | METEOR | ROUGE-L | CIDEr |
|---|---|---|---|---|---|---|---|
| ✓ | ✓ | ✓ | ✓ | 0.594 | 0.425 | 0.747 | 2.997 |
| ✗ | ✓ | ✓ | ✓ | 0.283 | 0.244 | 0.379 | 0.850 |
| ✓ | ✗ | ✓ | ✓ | 0.347 | 0.318 | 0.527 | 0.945 |
| ✓ | ✓ | ✗ | ✓ | 0.347 | 0.316 | 0.533 | 0.946 |
| ✗ | ✗ | ✗ | ✓ | 0.350 | 0.317 | 0.529 | 0.950 |
| Image resolution | BLEU-4 | METEOR | ROUGE_L |
|---|---|---|---|
| 0.384 | 0.356 | 0.504 | |
| 0.594 | 0.425 | 0.747 |
| Parallel (%) | BLEU-4 | METEOR | ROUGE-L |
|---|---|---|---|
| 0 | 0.301 | 0.304 | 0.448 |
| 25 | 0.594 | 0.425 | 0.747 |
| 50 | 0.358 | 0.339 | 0.484 |
Medical VQA
Medical visual question answering studies how AI systems answer clinical questions using medical images and related patient or report data.
See all 175 papers