cs.CVMar 16, 2026

Beyond the Embedding Bottleneck: Adaptive Retrieval-Augmented 3D CT Report Generation

Authors: Renjie Liang, Yiling Ma, Yang Xing, Zhengkang Fan, Jinqian Pan, Chengkun Sun, Li Li, Kuang Gong, +1 more

Organizations: University of Florida · Yale University · University of Southern California

Abstract

Automated radiology report generation from 3D CT volumes often suffers from incomplete pathology coverage. We provide empirical evidence that this limitation stems from a representational bottleneck: contrastive 3D CT embeddings encode discriminative pathology signals, yet exhibit severe dimensional concentration, with as few as 2 effective dimensions out of 512. Corroborating this, scaling the language model yields no measurable improvement, suggesting that the bottleneck lies in the visual representation rather than the generator. This bottleneck limits both generation and retrieval; naive static retrieval fails to improve clinical efficacy and can even degrade performance. We propose \textbf{AdaRAG-CT}, an adaptive augmentation framework that compensates for this visual bottleneck by introducing supplementary textual information through controlled retrieval and selectively integrating it during generation. On the CT-RATE benchmark, AdaRAG-CT achieves state-of-the-art clinical efficacy, improving Clinical F1 from 0.420 (CT-Agent) to 0.480 (+6 points); ablation studies confirm that both the retrieval and generation components contribute to the improvement. Code is available at https://github.com/renjie-liang/Adaptive-RAG-for-3DCT-Report-Generation.

Figures & tables

Appendix figures & tables7 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 29, 2026cs.CV

Generating Reports or Repeating Templates? Measuring and Mitigating Template Collapse in 3D CT Report Generation

Modern 3D medical vision-language models (VLMs) can generate fluent radiology-style text while exhibit critically low pathology detection and output diversity, collapsing to generic templates that under-report rare yet critical findings. We identify this failure mode as Template Collapse. This failure stems from the unique constraints of 3D medical imaging, e.g., limited data, severe label imbalance, and weak signals from volumetric encoders. Under these constraints, text-generation objectives encourage shortcut learning and fluent but weakly grounded reports. We systematically diagnose the Template Collapse through clinical fidelity, output diversity, normal-template bias, and rare-finding survival. To mitigate it, we propose CLarGen, a decoupled framework that separates what to say (clinical detection) from how to say it (language synthesis). CLarGen uses (i) a Latent Query Transformer for multi-label pathology detection, (ii) pathology-guided retrieval for clinically matched exemplars, and (iii) a medical language model to synthesize the final report from detected findings and retrieved context. Across state-of-the-art 3D CT report generation baselines, CLarGen mitigates Template Collapse and substantially improves clinical accuracy (macro-F1 0.487 vs. 0.189; CRG 0.472 vs. 0.368) while maintaining fluent reporting. Our results suggest that explicit, measurable clinical grounding is essential for template-collapse-resistant 3D CT report generation. Code is available at https://github.com/ai-med/CLarGen.
Apr 16, 2026cs.AI

RadAgent: A tool-using AI agent for stepwise interpretation of chest computed tomography

Vision-language models (VLM) have markedly advanced AI-driven interpretation and reporting of complex medical imaging, such as computed tomography (CT). Yet, existing methods largely relegate clinicians to passive observers of final outputs, offering no interpretable reasoning trace for them to inspect, validate, or refine. To address this, we introduce RadAgent, a tool-using AI agent that generates CT reports through a stepwise and interpretable process. Each resulting report is accompanied by a fully inspectable trace of intermediate decisions and tool interactions, allowing clinicians to examine how the reported findings are derived. In our experiments, we observe that RadAgent improves chest CT report generation over its 3D VLM counterpart, CT-Chat, across three dimensions. Clinical accuracy improves by 5.8 points (35.4% relative) in macro-F1 and 5.1 points (18.6% relative) in micro-F1. Robustness under adversarial conditions improves by 24.7 points (41.9% relative). Furthermore, RadAgent achieves 37.0% in faithfulness, a new capability entirely absent in its 3D VLM counterpart. By structuring the interpretation of chest CT as an explicit, tool-augmented and iterative reasoning trace, RadAgent brings us closer toward transparent and reliable AI for radiology.
Jul 15, 2026cs.CV

MonteRET: AI Agent Enhancing Multimodal LLMs with Multi-granularity Knowledge Retrieval for Chest CT Report Generation

Automated chest CT report generation remains challenging because clinically faithful reporting requires both whole-volume understanding and accurate description of localized anatomical findings. Here we developed and retrospectively evaluated MonteRET, a region-aware retrieval-enhanced framework for generating chest CT findings sections. MonteRET integrates global CT features with region-level anatomical representations, retrieves clinically relevant knowledge using predicted medical conditions and region-level vision-language alignment, and refines initial reports through a knowledge-guided report rewriting agent. We trained our model on a public cohort with 24,128 CT scans from RadGenome-ChestCT. We evaluated MonteRET on the public RadGenome-ChestCT test set of 1,564 CT scans and an external cohort of 82 CT scans from NewYork-Presbyterian/Weill Cornell Medical Center. MonteRET improved report quality, semantic similarity, and clinical efficacy compared with a matched baseline and several state-of-the-art methods. Gains were most pronounced for recall, suggesting fewer omitted findings. Human expert evaluation by radiology residents also favored MonteRET.