Electroencephalography (EEG) provides a non-invasive window into neural dynamics at high temporal resolution and plays a pivotal role in clinical neuroscience research. Despite this potential, prevailing computational approaches to EEG analysis remain largely confined to task-specific classification objectives or coarse-grained pattern recognition, offering limited support for clinically meaningful interpretation. To address these limitations, we introduce NeuroNarrator, the first generalist EEG-to-text foundation model designed to translate electrophysiological segments into precise clinical narratives. A cornerstone of this framework is the curation of NeuroCorpus-160K, the first harmonized large-scale resource pairing over 160,000 EEG segments with structured, clinically grounded natural-language descriptions. Our architecture first aligns temporal EEG waveforms with spatial topographic maps via a rigorous contrastive objective, establishing spectro-spatially grounded representations. Building on this grounding, we condition a Large Language Model through a state-space-inspired formulation that integrates historical temporal and spectral context to support coherent clinical narrative generation. This approach establishes a principled bridge between continuous signal dynamics and discrete clinical language, enabling interpretable narrative generation that facilitates expert interpretation and supports clinical reporting workflows. Extensive evaluations across diverse benchmarks and zero-shot transfer tasks highlight NeuroNarrator's capacity to integrate temporal, spectral, and spatial dynamics, positioning it as a foundational framework for time-frequency-aware, open-ended clinical interpretation of electrophysiological data.
Figures & tables
Figure 1: Illustrative example of segment-level, clinically grounded EEG interpretation. In contrast to coarse recording-level interpretaion, this sample demonstrates the generation of a fine-grained clinical narrative for a 10-second segment. The generated text systematically synthesizes four dimensions of electrophysiological analysis: (i) Event & Clinical Labels, identifying specific morphological abnormalities (e.g., spike-and-slow-wave complexes); (ii) Spatial Energy Distribution, capturing prominent signal and energy variations in specific anatomical regions (e.g., right fronto-temporal); (iii) Frequency-Domain Features, identifying the dominant spectral bands; and (iv) Temporal Context, characterizing the non-stationary evolution of brain states relative to preceding segments.
Figure 2: NeuroNarrator architecture for spectro–spatially grounded and temporally coherent EEG-to-text generation. (a) Dual-stream spectro–spatial grounding encodes each EEG segment using a pretrained EEG encoder operating on multichannel waveforms and a frozen vision encoder processing the corresponding scalp topographic map. Modality-specific features are projected into a shared latent space and aligned via a contrastive objective, enforcing correspondence between spectral dynamics and spatial energy distributions. (b) State-space–inspired generative modeling conditions text generation on both the aligned spectro–spatial embedding of the current segment and a short trajectory of preceding EEG segments, serving as a proxy for latent brain-state evolution. These continuous embeddings are injected as soft prompt tokens, replacing designated placeholder positions in the language-model prompt alongside task instructions, enabling the synthesis of clinically grounded narratives that preserve waveform morphology, dominant frequency structure, spatial localization, and temporal dynamics.
Figure 3: Overview of NeuroCorpus-160K construction. (a) Distribution of the aggregated datasets across major clinical domains. (b) The unified data processing workflow, which transforms raw recordings into clinically grounded narratives via three stages: signal preprocessing, structured feature extraction, and LLM-driven description refinement.
Dataset
Task
Train
Test
Samples
Hours
Samples
Hours
AD-65 Miltiadous et al. (2023)
Alzheimer’s Disease Detection
5,460
15.17
1,382
3.84
ADHD-Child Nasrabadi et al. (2020)
ADHD Detection
1,147
3.19
330
0.92
Grasp-and-Lift Luciw et al. (2014)
Hand Manipulation Event Detection
2,531
7.03
894
2.48
HMC Alvarez-Estevez and Rijsman (2021)
Sleep Stage Classification
25,000
69.44
1,000
2.78
MDD-64 Mumtaz (2016)
Major Depressive Disorder Detection
5,738
15.94
1,466
4.07
Table 1: Constituent datasets and split statistics for NeuroCorpus-160K. Summary of the 16 public EEG datasets integrated into NeuroCorpus-160K, including the associated task and the sizes of the training and held-out test splits, reported as the number of non-overlapping 10-s segments (Samples) and total recording duration (Hours).
Component
Structured Template
LLM Refined Descriptions
Event & Clinical Labels
This EEG segment from a 19-year-old female subject is recorded during a mental arithmetic task with cognitive load.
In this EEG segment from a 19-year-old female subject recorded during a mental arithmetic task with cognitive load, the observed patterns reflect task-related dynamics across frequency bands and scalp regions.
Frequency-Domain Features(Conditioned on {xt−k}k=1N,xt )
The delta frequency band (0–4 Hz) exhibits the highest power and shows a moderate decrease. Theta activity (4–8 Hz) shows a noticeable increase, while the alpha band (8–12 Hz) presents a significant decrease. Stable readings are observed in both the beta (12–30 Hz) and gamma (30–50 Hz) bands, while the high-gamma band (50–75 Hz) remains consistently low.
The EEG power is predominantly concentrated in the fronto-central and parietal regions, with the C4 channel maintaining the highest energy levels.
Table 2: Example of the transformation from structured quantitative scaffolds to clinically grounded narratives. This comparison demonstrates the synthesis of rigid feature templates (left) into a fluent, coherent description (right). Note that while the Frequency-Domain refinement is conditioned on the spectral history of preceding segments ( {xt−k}k=1N ) alongside the current segment ( xt ) to infer temporal trends, only the current segment’s features are listed here for conciseness.
Dataset
Topographic Map Retrieval
EEG Signal Retrieval
R@1
R@5
R@10
MeanR
R@1
R@5
R@10
MeanR
AD-65 Miltiadous et al. (2023)
88.35
98.91
99.71
1.38
92.04
98.99
99.78
1.22
ADHD-Child Nasrabadi et al. (2020)
87.27
96.06
98.48
2.58
88.79
96.97
98.18
1.87
Grasp_and_Lift Luciw et al. (2014)
74.72
93.96
97.32
2.19
77.63
95.19
97.87
1.88
MDD-64 Mumtaz (2016)
85.95
97.82
99.11
1.50
87.65
98.29
99.05
1.51
Motor Imagery Schalk et al. (2004)
71.45
91.94
95.89
2.94
75.82
93.70
96.47
2.54
Table 3: Quantitative assessment of bidirectional spectro-spatial retrieval. The table reports cross-modal retrieval performance across 16 heterogeneous datasets, evaluating the alignment accuracy between temporal EEG embeddings and spatial topographic map embeddings. Metrics include Recall@K ( R@1,R@5,R@10 ; higher is better) and Mean Rank ( MeanR ; lower is better).
Figure 4: Visualization of the learned spectro-spatial manifold via t-SNE Maaten and Hinton (2008) projection. The plots depict the latent distribution of EEG segments (triangles) and corresponding topographic maps (circles) sampled from the held-out NeuroCorpus-160K evaluation split. Left: In the absence of contrastive alignment, the representations exhibit a distinct modality gap, with temporal and spatial features forming fragmented, disjoint clusters. Right: Following contrastive optimization, the embedding space demonstrates a rigorous topological correspondence; matched EEG and topographic map pairs are tightly co-located within dataset-specific clusters.
Figure 5: Statistical validation of the learned spectro-spatial metric space. Left: Cosine similarity matrix. The pronounced diagonal dominance confirms a rigorous one-to-one correspondence between temporal EEG embeddings and spatial topographic map embeddings, effectively minimizing off-diagonal ambiguity. Right: Distribution of cosine similarity scores for matched versus mismatched pairs.
Figure 6: Multi-dimensional clinical evaluation of generated narratives. We assess the physiological fidelity of NeuroNarrator on the held-out NeuroCorpus-160K test set using a structured GPT-4.1 adjudicator. To capture the complexity of expert interpretation, each generated narrative is scored against the ground truth along five complementary axes: (i) clinical event or condition identification, (ii) dominant brain region localization, (iii) dominant frequency band classification, (iv) temporal trend description, and (v) detection of salient non-dominant spectral changes, with each axis contributing one point to a maximum score of 5.
Figure 7: Alignment of human and automated scoring distributions. Comparison of clinical fidelity scores assigned by human experts versus the GPT-4.1 adjudicator on a stratified subset of 1,500 narratives.
Dataset
BERTScore
Fact-F1
ROUGE-L
AD-65 Miltiadous et al. (2023)
0.750 ± 0.045
0.665 ± 0.237
0.419 ± 0.079
ADHD-Child Nasrabadi et al. (2020)
0.743 ± 0.049
0.706 ± 0.218
0.411 ± 0.084
Grasp and Lift Luciw et al. (2014)
0.728 ± 0.044
0.737 ± 0.251
0.365 ± 0.078
MDD-64 Mumtaz (2016)
0.732 ± 0.044
0.747 ± 0.209
0.386 ± 0.079
Motor Imagery Schalk et al. (2004)
0.718 ± 0.044
0.692 ± 0.247
0.353 ± 0.076
PD-31 Rockhill et al. (2021)
0.741 ± 0.053
0.683 ± 0.235
0.397 ± 0.091
Table 4: Quantitative assessment of linguistic and semantic fidelity on NeuroCorpus-160K. Performance of NeuroNarrator across all held-out benchmark datasets is evaluated using complementary automated metrics: BERTScore, Rule-based Fact-F1 and ROUGE-L.
Methods
TUAB
TUEV
TUSL
SEED
HMC
Workload
Non-LLM Models
EEGNet Lawhern et al. (2018)
79.3 ± 0.3
35.7 ± 1.0
36.1 ± 3.8
47.1 ± 0.8
62.2 ± 0.8
61.1 ± 5.5
EEGConformer Song et al. (2022)
80.1 ± 0.3
32.1 ± 1.0
44.9 ± 2.1
44.9 ± 0.8
49.5 ± 0.8
75.5 ± 4.0
SPaRCNet Jing et al. (2023)
79.8 ± 1.1
31.4 ± 3.6
40.0 ± 3.2
48.6 ± 2.4
66.0 ± 1.7
73.2 ± 4.9
ContraWR Yang et al. (2023b)
82.3 ± 0.3
42.2 ± 1.4
39.9 ± 1.4
56.4 ± 2.8
69.8 ± 0.8
63.3 ± 3.1
CNN-Transformer Peh et al. (2022)
82.2 ± 0.6
36.0 ± 4.7
35.5 ± 3.1
56.2 ± 1.2
69.9 ± 0.5
58.3 ± 7.7
Table 5: Benchmarking Open-Vocabulary Interpretation Against Specialized Closed-Set Baselines. We report Balanced Accuracy across six representative subsets of NeuroCorpus-160K. The evaluation contrasts NeuroNarrator (an open-vocabulary generative model) against two categories of discriminative baselines: conventional non-LLM deep learning models and NeuroLM, a closed-set LLM baseline.
Figure 8: Cross-domain zero-shot generalization and architectural ablation analysis. (a) Zero-shot classification performance on three external datasets (Depression-122, Siena, and SEED-IV) strictly excluded from NeuroCorpus-160K. (b) Ablation study on NeuroCorpus-160K quantifying the contribution of specific modules to clinical narrative fidelity.
Electroencephalography (EEG) foundation models learn reusable representations of brain signals for transfer across people, tasks, and recording setups.
X-LANCE Lab, Shanghai Jiao Tong University, Shanghai, China · Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China