Cone-Beam CT Image Quality Enhancement Using A Latent Diffusion Model Trained with Simulated CBCT Artifacts

Authors: Naruki Murahashi, Mitsuhiro Nakamura, Megumi Nakao

Organizations: Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, JAPAN

Abstract

Cone-beam computed tomography (CBCT) images are problematic in clinical medicine because of their low contrast and high artifact content compared with conventional CT images. Although there are some studies to improve image quality, in regions subject to organ deformation, the anatomical structure may change after such image quality improvement. In this study, we propose an overcorrection-free CBCT image quality enhancement method based on a conditional latent diffusion model using pseudo-CBCT images. Pseudo-CBCT images are created from CT images using a simple method that simulates CBCT artifacts and are spatially consistent with the CT images. By performing self-supervised learning with these spatially consistent paired images, we can improve image quality while maintaining anatomical structures. Furthermore, extending the framework of the conditional diffusion model to latent space improves the efficiency of image processing. Our model was trained on pelvic CT-pseudo-CBCT paired data and was applied to both pseudo-CBCT and real CBCT data. The experimental results using data of 75 cases show that with our proposed method, the structural changes were less than 1/1000th (in terms of the number of pixels) of those of a conventional method involving learning with real images, and the correlation coefficient between the CT value distributions of the generated and reference images was 0.916, approaching the same level as conventional methods. We also confirmed that the proposed framework achieves faster processing and superior improvement performance compared with the framework of a conditional diffusion model, even under constrained training settings.

Figures & tables

Explore similar work

Oct 5, 2026

Anatomy-preserving unpaired cone-beam CT refinement for image-guided radiotherapy using pseudo-label guided diffusion

Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy, but scatter, beam hardening, noise, truncation, and other artifacts limit image quality and CT number accuracy. Paired CBCT and CT data are difficult to obtain clinically because of motion, anatomical changes, and acquisition mismatch. We present RefineCBCT, an unpaired CBCT refinement framework that uses pseudo-label guidance and short-step diffusion to reduce artifacts while preserving patient-specific anatomy. RefineCBCT was trained and evaluated on unpaired CBCT and planning CT data from public LUNG TCIA and PELVIC TCIA datasets and compared with representative GAN and diffusion based methods. On LUNG TCIA, it achieved the best results across all metrics, with MAE 19.411, RMSE 62.758, PSNR 30.845 dB, and SSIM 0.931. On PELVIC TCIA, it achieved the best MAE, PSNR, and SSIM, with values of 14.905, 36.671 dB, and 0.876. The refined images showed fewer streaking and shading artifacts, clearer anatomical boundaries, and improved soft tissue uniformity, with line profile and ROI analyses showing closer agreement with planning CT. These results suggest that RefineCBCT provides efficient and effective CBCT refinement under clinically realistic unpaired training conditions and may support more reliable CBCT use in image-guided radiotherapy workflows. Code is publicly available on GitHub, and the evaluated datasets are available from The Cancer Imaging Archive.
May 19, 2026

EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis

Cone-beam CT (CBCT) is routinely acquired during radiotherapy for patient setup, but its quantitative reliability is degraded by scatter, noise, and reconstruction artifacts, limiting Hounsfield Unit (HU) accuracy. We propose EPC-3D-Diff, a novel conditional 3D latent diffusion framework for volumetric CBCT to CT synthesis that introduces a projection domain equivariance loss derived from acquisition physics. Unlike common image domain equivariance, we exploit the fact that an in plane rotation of the volume corresponds to an angular shift in its projections. During training, we enforce this relationship by forward projecting rotated synthesized CT volumes and matching them to appropriately angle shifted projections of the paired target CT, yielding a physics consistent equivariance constraint integrated into the diffusion objective. To capture full 3D context efficiently, conditional diffusion is performed in a compact latent space learnt by a lightweight 3D autoencoder, preserving axial depth while downsampling in plane resolution for stable training. We validate on a paired head CBCT/CT phantom dataset, including repeat scans, and paired clinical data using patient wise splits, and perform single and mixed domain training, ablations, and comparisons with diffusion and CycleGAN. EPC-3D-Diff generalizes well and achieved substantial improvements, +7.4 dB (phantom) and +1.8 dB (clinical data) in PSNR compared to state of the art methods, alongside improved SSIM and HU accuracy, within tissue boundaries. Overall, EPC-3D-Diff improves robustness and physics consistency, supporting HU aware synthesis for downstream radiotherapy workflows. The open source code for EPC-3D-Diff is available at https://github.com/ALZAHRAALTALIB/EPC-3D-Diff.
Aug 9, 2026

Toward CT-Equivalent Image Quality in Low-Dose Radiotherapy Planning: Conditional Diffusion-Based CBCT-to-CT Synthesis and the Impact of CBCT Input Representation

During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose. To mitigate this, low-dose cone-beam CT (CBCT) is routinely acquired during treatment delivery. However, CBCT image quality remains insufficient for accurate dose calculation and adaptive radiotherapy planning due to increased scatter, noise, beam hardening, and reconstruction related artifacts. This study develops a supervised deep learning based CBCT to CT synthesis framework using a conditional denoising diffusion probabilistic model (DDPM), where the generation of a CT-based planning for accurate positioning and dose calculation is obtained using generative models with low dose CBCT imaging. Beyond demonstrating CBCT to CT synthesis, the primary objective is to investigate how the representation of CBCT input data, either standard clinical DICOM CBCT images or filtered back-projection (FDK) reconstructions from raw projection data, affects the performance of diffusion based CT synthesis. The overarching aim is to assess whether physics aware CBCT representations better support CT-equivalent image quality while maintaining reduced imaging dose in radiotherapy workflows.