cs.CVMar 31, 2026

Clinical DVH metrics as a loss function for 3D dose prediction in head and neck radiotherapy

Authors: Ruochen Gao, Marius Staring, Frank Dankers

Organizations: Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands. · Department of Radiation Oncology, Leiden University Medical Center, Leiden, the Netherlands.

Abstract

Purpose: Deep-learning-based three-dimensional (3D) dose prediction is widely used in automated radiotherapy workflows. However, most existing models are trained with voxel-wise regression losses, which are poorly aligned with clinical plan evaluation criteria based on dose-volume histogram (DVH) metrics. This study aims to develop a clinically guided loss formulation that directly optimizes clinically used DVH metrics while remaining computationally efficient for head and neck (H&N) dose prediction. Methods: We propose a clinical DVH metric loss (CDM loss) that incorporates differentiable D-metrics and surrogate V-metrics, together with a lossless bit-mask region-of-interest (ROI) encoding to improve training efficiency. The method was evaluated on 174 H&N patients using a temporal split (137 training, 37 testing). Results: Compared with MAE- and DVH-curve based losses, CDM loss substantially improved target coverage and satisfied all clinical constraints. Using a standard 3D U-Net, the PTV Score was reduced from 1.544 (MAE) to 0.491 (MAE + CDM), while OAR sparing remained comparable. Bit-mask encoding reduced training time by 83% and lowered GPU memory usage. Conclusion: Directly optimizing clinically used DVH metrics enables 3D dose predictions that are better aligned with clinical treatment planning criteria than conventional voxel-wise or DVH-curve-based supervision. The proposed CDM loss, combined with efficient ROI bit-mask encoding, provides a practical and scalable framework for H&N dose prediction.

Figures & tables

Explore similar work

Apr 11, 2026

Improving Deep Learning-Based Target Volume Auto-Delineation for Adaptive MR-Guided Radiotherapy in Head and Neck Cancer: Impact of a Volume-Aware Dice Loss

Background: Manual delineation of target volumes in head and neck cancer (HNC) remains a significant bottleneck in radiotherapy planning, characterized by high inter-observer variability and time consumption. This study evaluates the integration of a Volume-Aware (VA) Dice loss function into a self-configuring deep learning framework to enhance the auto-segmentation of primary tumors (PT) and metastatic lymph nodes (LN) for adaptive MR-guided radiotherapy. We investigate how volume-sensitive weighting affects the detection of small, anatomically complex nodal metastases compared to conventional loss functions. Methods: Utilizing the HNTS-MRG 2024 dataset, we implemented an nnU-Net ResEnc M architecture. We conducted a multi-label segmentation task, comparing a standard Dice loss baseline against two Volume-Aware configurations: a "Dual Mask" setup (VA loss on both PT and LN) and a "Selective LN Mask" setup (VA loss on LN only). Evaluation metrics included volumetric Dice scores, surface-based metrics (SDS, MSD, HD95), and lesion-wise binary detection sensitivity and precision. Results: The Selective LN Mask configuration achieved the highest LN Volumetric Dice Score (0.758 vs. 0.734 baseline) and significantly improved LN Lesion-Wise Detection Sensitivity (84.93% vs. 81.80%). However, a critical trade-off was observed; PT detection precision declined significantly in the selective setup (63.65% vs. 81.27%). The Dual Mask configuration provided the most balanced performance across both targets, maintaining primary tumor precision at 82.04% while improving LN sensitivity to 83.46%. Conclusions: A volume-sensitive loss function mitigated the under-representation of small metastatic lesions in HNC. While selective weighting yielded the best nodal detection, a dual-mask approach is required in multi-label tasks to maintain segmentation accuracy for larger primary tumor volumes.
Oct 19, 2026

Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning

Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.
Aug 27, 2026

Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning

Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage (D95D_{95}), though statistical analysis revealed a marginal reduction in target homogeneity (p<0.001p<0.001) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing (p<0.001p<0.001). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in 1111 out of 1414 Moderate Hypofraction Arm plans and 99 out of 1212 Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.