cs.CVMar 31, 2026

Less Is More? Selective Visual Attention to High-Importance Regions for Multimodal Radiology Summarization

Authors: Mst. Fahmida Sultana Naznin, Adnan Ibney Faruq, Mushfiqur Rahman, Niloy Kumar Mondal, Md. Mehedi Hasan Shawon, Md Rakibul Hasan

Organizations: Bangladesh University of Engineering and Technology, Dhaka 1000, Bangladesh · BRAC University, Dhaka 1212, Bangladesh · Curtin University, Bentley, WA 6102, Australia

Abstract

Automated radiology report summarization aims to distill verbose findings into concise clinical impressions, but existing multimodal models often struggle with visual noise and fail to meaningfully improve over strong text-only baselines in the FINDINGS →\to IMPRESSION transformation. We challenge two prevailing assumptions: (1) that more visual input is always better, and (2) that multimodal models add limited value when findings already contain rich image-derived detail. Through controlled ablations on MIMIC-CXR benchmark, we show that selectively focusing on pathology-relevant visual patches rather than full images yields substantially better performance. We introduce ViTAS, Visual-Text Attention Summarizer, a multi-stage pipeline that combines ensemble-guided MedSAM2 lung segmentation, bidirectional cross-attention for multi-view fusion, Shapley-guided adaptive patch clustering, and hierarchical visual tokenization feeding a ViT. ViTAS achieves SOTA results with 29.25% BLEU-4 and 69.83% ROUGE-L, improved factual alignment in qualitative analysis, and the highest expert-rated human evaluation scores. Our findings demonstrate that less but more relevant visual input is not only sufficient but superior for multimodal radiology summarization.

Figures & tables

Explore similar work

Jul 7, 2026

Harrison.Rad 1.5 Technical Report: A radiology foundation model that can draft reports from images, priors and clinical context

Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone. The most direct opportunity is reducing the time and effort radiologists spend producing reports, a task that requires interpreting images, integrating clinical history and prior studies, and drafting structured findings. We present Harrison.Rad 1.5 (HR1.5), a radiology-specific multimodal large language model that accepts interleaved text and visual inputs and generates structured and unstructured text across plain-film radiology, spanning computed radiography, chest, musculoskeletal, abdominal, spine, and pelvic x-rays, and mammography. HR1.5 is trained through a three-stage pipeline: domain adaptation of a base language model on radiology reports, contrastive vision-encoder training with curriculum-based hard negatives on ~6 million image-report instances, and visual-question-answering fine-tuning on multi-turn conversations. We evaluate it with a Findings-Diagnosis scoring framework that extends RadGraph-XL entity extraction with ontology-based synonym matching and polarity-contradiction detection, benchmarked on RadBench, a simulated FRCR 2B Short Case examination scored against Angoff-method thresholds, ReXGradient, and internal multi-modality datasets. HR1.5 is the only system evaluated to meet the simulated FRCR passing standard and achieves the highest accuracy on closed-format clinical questions, across anatomical regions, on internal multi-body-part and mammography reporting, and on the primary clinically-aligned score for public chest reporting. We further examine explainability and model behaviour, including question-sensitive Grad-CAM heatmaps, attention analysis, and confidence estimation, to support responsible future evaluation toward clinical use, and a framework for clinically grounded assessment of report quality.
Jun 16, 2026

Vision-language models for chest radiography do not always need the image

Vision-language models that answer questions about chest radiographs are evaluated by their accuracy on labels derived from radiology reports. High benchmark accuracy is often interpreted as evidence that the model uses the image. A model that answers from the finding named in the question can score as well as a model that uses the radiograph. Keeping the question fixed, we audit eight open-weight systems by swapping in another patient's radiograph with the same or the opposite label, occluding the radiologist-marked region or an equal region elsewhere, and removing the radiograph or replacing it with noise or a photograph. On 2,548 yes-or-no questions from MIMIC-CXR, one multimodal model answers Yes regardless of the image, another multimodal model changes its answers without following the label, and four systems use the image but keep about half of their correct answers when the radiograph is swapped for an opposite-label radiograph. A medical model that receives only the question text scores 55.3% on the pooled questions, higher than two multimodal systems. It scores 91.8% where every finding is present, and answering Yes to every question scores 100% there. Where the image is necessary, the best multimodal system exceeds this model by 10.4% in balanced accuracy. The categories are unchanged on CheXpert. Confidence is not higher when a correct answer depends on the marked region. In a reader study with three radiologists, the two radiologists who read a balanced set of 200 cases score 86.0% and 82.0%, and the systems score 50.0% to 73.0%. Accuracy does not establish image use, but an intervention on the image can test it.
Mar 24, 2026

RadTimeline: Timeline Summarization for Longitudinal Radiological Lung Findings

Tracking findings in longitudinal radiology reports is crucial for accurately identifying disease progression, and the time-consuming process would benefit from automatic summarization. This work introduces a structured summarization task, where we frame longitudinal report summarization as a timeline generation task, with dated findings organized in columns and temporally related findings grouped in rows. This structured summarization format enables straightforward comparison of findings across time and facilitates fact-checking against the associated reports. The timeline is generated using a 3-step LLM process of extracting findings, generating group names, and using the names to group the findings. To evaluate such systems, we create RadTimeline, a timeline dataset focused on tracking lung-related radiologic findings in chest-related imaging reports. Experiments on RadTimeline show tradeoffs of different-sized LLMs and prompting strategies. Our results highlight that group name generation as an intermediate step is critical for effective finding grouping. The best configuration has some irrelevant findings but very good recall, and grouping performance is comparable to human annotators.