How Long short-term memory artificial neural network, synthetic data, and fine-tuning improve the classification of raw EEG data
Authors: Albert Nasybullin, Vladimir Maksimenko, Semen Kurkin
Organizations: Laboratory of Data Analysis and Bioinformatics, Center for Artificial Intelligence, Innopolis University, Innopolis, Russia · Neuroscience and Cognitive Technology Laboratory, Center for Technologies in Robotics and Mechatronics Components, Innopolis University, Innopolis, Russia
In this paper, we discuss a Machine Learning pipeline for the classification of EEG data. We propose a combination of synthetic data generation, long short-term memory artificial neural network (LSTM), and fine-tuning to solve classification problems for experiments with implicit visual stimuli, such as the Necker cube with different levels of ambiguity. The developed approach increased the quality of the classification model of raw EEG data.
Figures & tables
Fig. 1: Ambiguous values of the Necker cube in visual stimulus [ 9 ]
Class labels
”Left”
”High-ambiguity”
”Right”
Ambiguity values
0.15, 0.25
0.4, 0.45, 0.55, 0.6
0.75, 0.85
Total dataset size
997
2 000
1 003
Train subset size
598
1 200
602
Test subset size
399
800
401
TABLE I: Original dataset structure
Fig. 2: The architecture of the Long short-term memory artificial neural network model used for classification.
Fig. 3: We build our intuition behind data expanding strategy on a difference created in a signal by band-pass filtering.
Training data subset
F-1 score
Original
Theta
Alpha
Beta
0.63
+
0.78
+
+
0.71
+
+
0.69
+
+
0.73
+
+
+
+
TABLE II: Model evaluation with different pre-trained weights
We investigate whether a generative model can supply useful synthetic motor-imagery (MI) electroencephalography (EEG) trials that improve the accuracy of independent downstream classifiers. We train a class-conditional variational autoencoder (CVAE) with an integrated latent classifier on the Zhou motor-imagery dataset, using the learned per-class prior as a generator: sampling the prior for a given label and decoding it into a synthetic, label-consistent signal. A constraint on the covariance matrix of the generated data encourages preservation of covariance structure, and the model is trained with a schedule that alternates ordinary VAE training with a decoder-focused phase that sharpens the generative pathway used for augmentation. We measure the effect of adding synthetic trials to the training set under two evaluation protocols -- within-user (pooled 60/20/20 split across subjects) and cross-user (leave-one-subject-out, LOSO) -- across four representative EEG classification pipelines: Common Spatial Patterns with Linear Discriminant Analysis (CSP+LDA), tangent-space features with a Support Vector Machine (TGSP+SVM), Minimum Distance to Riemannian Mean (MDM), and a neural network based on EEGNetv4 (henceforth EEGNet). Results are aggregated across independent augmentation draws, random seeds (within-user), or leave-one-subject-out folds (cross-user), with uncertainty reported as 95% confidence intervals (Student's t-distribution) computed over per-seed/per-fold averages. We find that synthetic EEG from the CVAE is most credible as a source of class-structured, covariance-like data rather than as a substitute for real raw EEG: it can raise the point estimate for MDM, but the broader augmentation claim remains conservative -- observed gains are small and classifier-dependent.
Matei Moldoveanu, Alain Sirois, Claire Ben Ali +2
Naqi Logix, Paris, France · Inria Center at Univ. Bordeaux / LaBRI, Talence, France · LITIS, INSA Rouen-Normandy, France
In this paper, we consider applying computer vision algorithms for the classification problem one faces in neuroscience during EEG data analysis. Our approach is to apply a combination of computer vision and neural network methods to solve human brain activity classification problems during hand movement. We pre-processed raw EEG signals and generated 2D EEG topograms. Later, we developed supervised and semi-supervised neural networks to classify different motor cortex activities.
Albert Nasybullin, Semen Kurkin
Faculty of Computer Science and Engineering, Innopolis University, Innopolis, Russia · Neuroscience and Cognitive Technology Laboratory, Center for Technologies in Robotics and Mechatronics Components, Innopolis University, Innopolis, Russia
Electroencephalography (EEG) is a promising, non-invasive, and cost-effective modality for Alzheimer's disease (AD) detection, but deep learning methods are limited by small and imbalanced clinical datasets. Generative augmentation offers a solution, yet existing approaches rely on inefficient class-specific models or fail to capture complex spatial and temporal brain dynamics. To address this, we propose GraM-Diff, a unified classifier-guided Graph-Mamba diffusion framework for EEG synthesis. It embeds Graph Convolutional Networks within a diffusion U-Net to model inter-electrode connectivity and Bidirectional Mamba state-space blocks for linear-complexity long-range temporal modeling. Latent-space classifier guidance lets a single model generate both healthy and pathological EEG within a shared representation, avoiding fragmented per-cohort pipelines. Across four EEG-based AD benchmarks, synthetic augmentation improves classification, yields superior Context-FID and correlation scores over strong generative baselines, and enhances robustness in data-scarce settings.
M. Tanveer, Ayush Singh Rana, Sanskriti Jain +5