cs.CVApr 6, 2026

No-reference based automatic parameter optimization for iterative reconstruction using a novel search space aware crow search algorithm

Authors: Poorya MohammadiNasab, Ander Biguri, Philipp Steininger, Peter Keuschnigg, Lukas Lamminger, Agnieszka Lach, S M Ragib Shahriar Islam, Anna Breger, +4 more

Organizations: Department of Medicine, Danube Private University (DPU), Krems, Austria · Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria · Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge, United Kingdom · MedPhoton GmbH, Salzburg, Austria · Austrian Center for Medical Innovation and Technology (ACMIT), Wiener Neustadt, Austria · Faculty of Mathematics, University of Vienna, Vienna, Austria

Abstract

Iterative reconstruction technique's ability to reduce radiation exposure by using fewer projections has attracted significant attention. However, these methods typically require a precise tuning of several hyperparameters, which can have a major impact on reconstruction quality. Manually setting these parameters is time-consuming and increases the workload for human operators. In this paper, we introduce a novel fully automatic parameter optimization framework that can be applied to a wide range of Cone-beam computed tomography (CBCT) iterative reconstruction algorithms to determine optimal parameters without requiring a reference reconstruction. The proposed method incorporates a modified crow search algorithm (CSA) featuring a superior set-dependent local search mechanism, a search-space-aware global search strategy, and an objective-driven balance between local and global search. Additionally, to ensure an effective initial population, we propose a chaotic diagonal linear uniform initialization scheme that accelerates algorithm convergence. The performance of the proposed framework was evaluated on three imaging machines and four real datasets, as well as three different iterative reconstruction methods with the highest number of tunable parameters, representing the most challenging senario. The results indicate that the proposed method could outperform manual settings and CSA, with an 4.19% improvement in average fitness and 4.89% and 3.82% improvements on CHILL@UK and RPI_AXIS, respectively, which are two benchmark no-reference learning-based quality metrics. In addition, the qualitative results clearly show the superiority of the proposed method by maintaining fine details sharply. The overall performance of the proposed framework across different comparison scenarios demonstrates its effectiveness and robustness across all cases.

Figures & tables

Explore similar work

Sep 10, 2026

Task-Based CT Protocol Optimization Using Reinforcement Learning and Virtual Imaging Trials

Protocol optimization in computed tomography (CT) aims to improve diagnostic image quality while reducing radiation dose, but the interdependence of acquisition and reconstruction parameters makes exhaustive testing impractical. We propose a virtual imaging trial framework with reinforcement learning for efficient CT protocol optimization. Sixty-three computational human models with liver lesions were imaged using a validated CT simulator across 468 combinations of acquisition and reconstruction parameters, including tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization objective balanced liver lesion detectability, quantified by detectability index d-prime, against radiation dose. A Proximal Policy Optimization agent was trained and conditioned on patient-specific CT localizer embeddings derived from a pretrained vision transformer. On held-out patients, evaluating only 8 protocols per patient, about 2% of exhaustive testing, recovered 98.2% of the exhaustive-search oracle objective. With no patient-specific simulation, surrogate scoring alone achieved 89.7% recovery. Conditioning on the localizer improved zero-simulation recovery by 10.7 percentage points over the localizer-blind policy (paired 95% CI 2.9-19.5; p=0.02). These results show that the proposed framework can substantially reduce exhaustive protocol testing while enabling task-based, dose-aware protocol selection before the diagnostic scan.
Jun 25, 2026

Enabling self-supervised learned primal dual with Noise2Inverse

X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete. While learned reconstruction methods such as the Learned Primal-Dual algorithm achieve strong performance, they typically rely on supervised training with access to ground-truth data, which is often unavailable in practice. In this work, we propose a self-supervised reconstruction method by extending the Noise2Inverse framework to the Learned Primal-Dual algorithm. The resulting approach, called Noise2Inverse Learned Primal-Dual (N2I-LPD), enables training of a learned iterative reconstruction operator without ground-truth images by exploiting the statistical independence of noise in distinct measurements with respect to angular rotation of the CT-scan. We compare the proposed method with classical reconstruction methods, as well as neural network-based approaches such as a U-Net trained within the same N2I framework. The results demonstrate that N2I-LPD achieves improved reconstruction quality, highlighting the potential of combining learned reconstruction operators with self-supervised training strategies for practical CT imaging scenarios where ground-truth data is unavailable.
Jul 4, 2026

SAVER: Stochastic Adaptive Variance-Driven Exploration and Reconstruction for Low-Dose Computed Tomography

Computed Tomography (CT) is indispensable in clinical diagnostics, yet minimizing radiation dose without compromising image quality remains a critical challenge. Conventional low-dose protocols often rely on fixed, uniform angular sampling, independent of the underlying structural complexity of organs of individual patients. We propose ``Stochastic Adaptive Variance-Driven Exploration and Reconstruction'' (SAVER), an adaptive data acquisition framework that selects projection angles in real-time based on the statistical variance of acquired data. Utilizing a Softmax-based stochastic scheduling scheme with simulated annealing, SAVER prioritizes directions with high structural information while maintaining necessary exploration. Numerical experiments across 8 diverse phantoms demonstrate that SAVER achieves consistently higher reconstruction fidelity than conventional random sampling, particularly for objects with high structural anisotropy. Furthermore, the proposed method exhibits robust performance under significant measurement noise. By dynamically reallocating radiation dose to the most informative projections, SAVER provides a mathematically-grounded approach to maximize diagnostic quality per unit of radiation dose, marking a shift toward sample-dependent, data-driven CT acquisition.