AI applications driven by multimodal large language models (MLLMs) are prone to hallucinations and pose considerable risks to human users. Crucially, such hallucinations are not equally problematic: some hallucination contents could be detected by human users(i.e., obvious hallucinations), while others are often missed or require more verification effort(i.e., elusive hallucinations). This indicates that multimodal AI hallucinations vary significantly in their verifiability. Yet, little research has explored how to control this property for AI applications with diverse security and usability demands. To address this gap, we construct a dataset from 4,470 human responses to AI-generated hallucinations and categorize these hallucinations into obvious and elusive types based on their verifiability by human users. Further, we propose an activation-space intervention method that learns separate probes for obvious and elusive hallucinations. We reveal that obvious and elusive hallucinations elicit different intervention probes, allowing for fine-grained control over the model's verifiability. Empirical results demonstrate the efficacy of this approach and show that targeted interventions yield superior performance in regulating corresponding verifiability. Moreover, simply mixing these interventions enables flexible control over the verifiability required for different scenarios.
Figures & tables
Figure 1: Illustration of verifiability of hallucinations. The same image–text pair can yield hallucinations that are obvious (easy to verify) or elusive (difficult to verify).
Figure 2: Overview of our data construction pipeline. (a) constructs questionnaires with candidate image-text pairs; (b) collects human judgments; (c) performs hallucination attribution to build a human-labeled dataset.
Figure 3: Joint visualization of hallucination-rate reduction under OHI and EHI across validation and test sets. Each point corresponds to a single-direction coefficient sweep, revealing a consistent spatial separation between the two interventions across three MLLMs.
Model
Type
OHS
EHS
ACC(%)
UT(%)
ACC(%)
UT(%)
Qwen2.5-VL-3B
OHI
+5.79
+26.28
+4.73
+20.3
EHI
+2.52
+17.10
+3.15
+13.50
Qwen2.5-VL-7B
OHI
+9.14
-1.08
+5.22
-0.47
EHI
+16.99
+0.43
+14.22
+0.85
LLaVA-OneVision-1.5-8B
OHI
+32.75
+2.51
+24.82
+1.76
Table 1: Effects of OHI and EHI on ACC(%) and UT(%) across different test subsets under the selected intervention settings. Values denote absolute changes relative to the baseline.
Model
OHS
EHS
OHI
EHI
Δ
OHI
EHI
Δ
Qwen2.5-VL-3B
-32.07
-19.56
+12.51
-25.04
-16.65
+8.39
Qwen2.5-VL-7B
-8.06
-17.42
-9.36
-4.76
-15.08
-10.32
LLaVA-OneVision-1.5-8B
-35.26
-17.53
+17.73
-26.58
-19.43
+7.15
Table 2: Effects of OHI and EHI on HR(%) across different test subsets under the selected intervention settings. We also report Δ , defined as the difference between the two subsets ( Δ=EHI−OHI ).
Table 3: Influence on general ability under the selected intervention coefficients. We report accuracy (%) on general understanding benchmarks. Color intensity reflects the change compare to base model. (Green for improvements, Red for declines).
Figure 4: Layer-wise cosine similarity between obvious and elusive hallucination directions.
Figure 5: Layer comparison of OHI and EHI in Qwen2.5-VL-7B and LLaVA-OneVision-1.5-8B. The figure shows the average hallucination rate over post-instruction token positions.
Figure 6: Verifiability steering via the mixed direction on Qwen2.5-VL-7B and LLaVA-OneVision-1.5-8B. We fix the ablation strength α=1 and vary the mixing coefficient λ .
Figure 7: Case studies of intervention effects on LLaVA-OneVision-1.5-8B. Hallucinated content is highlighted in red, and corrected or image-grounded content is highlighted in green. The mixed-direction intervention is performed with λ=0.5 .
Model
Type
i
l/L
hr_h_score
Δacc_nh
kl_score
Qwen2.5-VL-3B
OHI
-1
29/36
-1.01
-0.32
0.08
EHI
-2
25/36
-0.27
-0.08
0.04
Qwen2.5-VL-7B
OHI
-4
20/28
-0.54
-0.06
0.04
EHI
-5
20/28
-0.49
0.03
0.04
LLaVA-OneVision-1.5-8B
OHI
-2
26/36
-1.23
0.02
0.09
EHI
-2
23/36
-0.64
0.07
0.06
Table 4: Direction selection details for each model. Note that i=−1 indicates that the direction is selected from the last token position, i=−2 the second-to-last token position, and so on. Also note that the layer index l starts from index 0, while L indicates the total number of layers.
Model
Type
Obvious Hallucination Subset
Elusive Hallucination Subset
Non-Hallucination Subset
HR(%)
ACC(%)
UT(%)
HR(%)
ACC(%)
UT(%)
HR(%)
ACC(%)
UT(%)
Qwen2.5-VL-3B
OHI
-32.07
+5.79
+26.28
-25.04
+4.73
+20.30
-3.26
-0.64
+3.90
EHI
-19.56
+2.52
+17.10
-16.65
+3.15
+13.50
-1.26
-3.66
+4.92
Qwen2.5-VL-7B
OHI
-8.06
+9.14
-1.08
-4.76
+5.22
-0.47
-3.32
+5.74
-2.43
EHI
-17.42
+16.99
+0.43
-15.08
+14.22
+0.85
+2.72
-1.78
-0.94
LLaVA-OneVision-1.5-8B
OHI
-35.26
+32.75
+2.51
-26.58
+24.82
+1.76
-1.78
+1.39
+0.39
Table 5: Full intervention results across all test sets. For each metric, we report the absolute change in hallucination rate (HR), accuracy (ACC), and uncertain tendency (UT) under the OHI and EHI.
Figure 13
Model
αoh
αeh
Qwen2.5-VL-3B
0.90
0.90
Qwen2.5-VL-7B
0.80
0.70
LLaVA-OneVision-1.5-8B
0.80
0.80
Table 6: Selected intervention coefficients for OHI and EHI.