Distilling Photon-Counting CT into Routine Chest CT through Clinically Validated Degradation Modeling

Authors: Junqi Liu, Xinze Zhou, Wenxuan Li, Scott Ye, Arkadiusz Sitek, Xiaofeng Yang, Yucheng Tang, Daguang Xu, 

Organizations: Johns Hopkins University · University of California, San Francisco · Harvard Medical School · Emory University · 

Abstract

Photon-counting CT (PCCT) provides superior image quality with higher spatial resolution and lower noise compared to conventional energy-integrating CT (EICT), but its limited clinical availability restricts large-scale research and clinical deployment. To bridge this gap, we propose SUMI, a simulated degradation-to-enhancement method that learns to reverse realistic acquisition artifacts in low-quality EICT by leveraging high-quality PCCT as reference. Our central insight is to explicitly model realistic acquisition degradations, transforming PCCT into clinically plausible lower-quality counterparts and learning to invert this process. The simulated degradations were validated for clinical realism by board-certified radiologists, enabling faithful supervision without requiring paired acquisitions at scale. As outcomes of this technical contribution, we: (1) train a latent diffusion model on 1,046 PCCTs, using an autoencoder first pre-trained on both these PCCTs and 405,379 EICTs from 145 hospitals to extract general CT latent features that we release for reuse in other generative medical imaging tasks; (2) construct a large-scale dataset of over 17,316 publicly available EICTs enhanced to PCCT-like quality, with radiologist-validated voxel-wise annotations of airway trees, arteries, veins, lungs, and lobes; and (3) demonstrate substantial improvements: across external data, SUMI outperforms state-of-the-art image translation methods by 15% in SSIM and 20% in PSNR, improves radiologist-rated clinical utility in reader studies, and enhances downstream top-ranking lesion detection performance, increasing sensitivity by up to 15% and F1 score by up to 10%. Our results suggest that emerging imaging advances can be systematically distilled into routine EICT using limited high-quality scans as reference.

Figures & tables

Explore similar work

May 14, 2026

CT-DegradBench: A Physics-Informed Benchmark for CT Degradation Detection and Severity Estimation

Computed tomography (CT) images are frequently degraded by acquisition artifacts, including noise, blur, streaking, aliasing, and metal artifacts. Yet CT enhancement is still largely evaluated using image quality metrics with limited perceptual and clinical validity, while existing datasets remain focused on isolated restoration tasks, hindering unified benchmarking across diverse degradation types. We present CT-DegradBench, a dataset and benchmark for CT degradation detection and severity estimation under controlled single- and mixed-artifact settings. CT-DegradBench enables systematic evaluation across multiple degradation families and severity levels within a common experimental framework. We further propose SeSpeCT (Semantic-Spectral CT degradation estimation), a framework that combines semantic priors from medical vision-language models with complementary frequency-domain cues for artifact analysis. SeSpeCT constructs a training-free semantic quality axis in the multimodal embedding space using radiology-informed text prompts, without task-specific fine-tuning, and combines it with spectral features that capture degradation-specific frequency patterns. The resulting representation enables joint prediction of artifact type and severity. Experimental results show that SeSpeCT consistently outperforms the evaluated baselines under both single- and mixed-degradation settings. The framework is available at https://github.com/yousranb/CT-DEGRADBENCH.
Mar 27, 2026

Cone-Beam CT Image Quality Enhancement Using A Latent Diffusion Model Trained with Simulated CBCT Artifacts

Cone-beam computed tomography (CBCT) images are problematic in clinical medicine because of their low contrast and high artifact content compared with conventional CT images. Although there are some studies to improve image quality, in regions subject to organ deformation, the anatomical structure may change after such image quality improvement. In this study, we propose an overcorrection-free CBCT image quality enhancement method based on a conditional latent diffusion model using pseudo-CBCT images. Pseudo-CBCT images are created from CT images using a simple method that simulates CBCT artifacts and are spatially consistent with the CT images. By performing self-supervised learning with these spatially consistent paired images, we can improve image quality while maintaining anatomical structures. Furthermore, extending the framework of the conditional diffusion model to latent space improves the efficiency of image processing. Our model was trained on pelvic CT-pseudo-CBCT paired data and was applied to both pseudo-CBCT and real CBCT data. The experimental results using data of 75 cases show that with our proposed method, the structural changes were less than 1/1000th (in terms of the number of pixels) of those of a conventional method involving learning with real images, and the correlation coefficient between the CT value distributions of the generated and reference images was 0.916, approaching the same level as conventional methods. We also confirmed that the proposed framework achieves faster processing and superior improvement performance compared with the framework of a conditional diffusion model, even under constrained training settings.
Oct 7, 2026

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.