cs.CVApr 11, 2026

Radiology Report Generation for Low-Quality X-Ray Images

Authors: Hongze Zhu, Chen Hu, Jiaxuan Jiang, Hong Liu, Yawen Huang, Ming Hu, Tianyu Wang, Zhijian Wu, +1 more

Organizations: Westlake University · Tencent Jarvis Lab

Abstract

Vision-Language Models (VLMs) have significantly advanced automated Radiology Report Generation (RRG). However, existing methods implicitly assume high-quality inputs, overlooking the noise and artifacts prevalent in real-world clinical environments. Consequently, current models exhibit severe performance degradation when processing suboptimal images. To bridge this gap, we propose a robust report generation framework explicitly designed for image quality variations. We first introduce an Automated Quality Assessment Agent (AQAA) to identify low-quality samples within the MIMIC-CXR dataset and establish the Low-quality Radiology Report Generation (LRRG) benchmark. To tackle degradation-induced shifts, we propose a novel Dual-loop Training Strategy leveraging bi-level optimization and gradient consistency. This approach ensures the model learns quality-agnostic diagnostic features by aligning gradient directions across varying quality regimes. Extensive experiments demonstrate that our approach effectively mitigates model performance degradation caused by image quality deterioration. The code and data will be released upon acceptance.

Figures & tables

Explore similar work

Mar 11, 2024

Multimodal Large Language Model driven Radiology Report Generation with Clinical Knowledge Enhancement

Radiology report generation (RRG) has attracted significant attention due to its potential to reduce the workload of radiologists. The performance of current RRG approaches remains unsatisfactory against clinical standards. This paper introduces a novel RRG method, MLLM-RRG, that integrates multimodal large language models (MLLMs) with various types of clinical knowledge to generate accurate and comprehensive chest X-ray reports. Our method first designs a referring anatomical feature extractor that leverages anatomical knowledge to analyze different regions of the chest X-ray image and extract visual features without explicitly detecting regions. Next, based on the MLLM's decoder, we develop a multimodal report generator that leverages multimodal prompts constructed from dedicated visual features and textual instructions to produce the radiology report in an auto-regressive way. Finally, we introduce a disease-oriented clinical classification and alignment scheme in a multi-task learning manner to leverage disease knowledge to better preserve the clinical relevance among the generated reports. Once the model is trained, we also introduce a novel clinical quality reinforcement learning strategy to enhance the MLLM with report knowledge, further refining the tones of the generated reports towards radiologists. Extensive experiments on the MIMIC-CXR and IU X-Ray datasets demonstrate the superiority of our method over the state of the art. Our codes will be available at https://github.com/viscom-tongji/MLLM-RRG.
Oct 9, 2026

CliQ-RRG: Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report Generation

Radiology reports are essential for diagnostic reasoning and patient care, yet their manual preparation is time-consuming and cognitively demanding. Automatic radiology report generation (RRG) offers a scalable alternative, but existing models often produce lengthy, unstructured narratives that overlook diagnostic cues and multi-view information. We present Clinical-Knowledge Guided Disease-aware Visual-Textual Alignment for QA-Style Radiology Report Generation (CliQ-RRG), a unified two-stage framework for interpretable and clinically grounded reporting. In Stage 1, CliQ-RRG employs a Disease-aware Visual-Textual Alignment module that aligns image and text representations using predicted disease embeddings, reinforced by a Prior-Guided Attention Module (PrAM) to capture multi-view dependencies across current and prior scans. In Stage 2, GraphRAG-guided retrieval augments intermediate textual representations with graph-grounded clinical evidence, and a large language model restructures them into concise, interpretable question-answer (QA) pairs with diagnostic summaries. Experiments on two public chest X-ray benchmarks demonstrate that CliQ-RRG consistently outperforms prior methods across both lexical and clinical metrics, generating accurate and clinically coherent QA-style radiology reports. Code is available at: https://github.com/chandravardhan-singh-raghaw/CliQ-RRG.
Aug 25, 2026

DRRG: A Discrete Diffusion Framework for Radiology Report Generation

Purpose: Automatic radiology report generation (RRG) has been widely explored to improve reporting accuracy and reduce radiologists' workload. Most existing methods rely on autoregressive (AR) frameworks that generate reports token by token and cannot revise earlier content, making them prone to error propagation and inconsistent with the iterative refinement process of radiological reporting. In contrast, discrete diffusion large language models (DLLMs) generate text through iterative denoising, naturally enabling report refinement. However, DLLMs have not been extensively investigated for RRG. In this study, we developed and evaluated a discrete diffusion framework for RRG that enables iterative refinement rather than conventional left-to-right autoregressive decoding. Materials and methods: We developed DRRG, a DLLM-based framework that formulates RRG as iterative masked-token denoising. DRRG incorporates a clinical-entities-aware complementary mask to improve token supervision coverage and emphasize clinically important entities, together with a concept-conditioning module that injects image-derived clinical concepts into visual representations. DRRG was trained and evaluated on MIMIC-CXR and CheXpert Plus. Results: On MIMIC-CXR, DRRG achieved BLEU-4 of 0.210, CheXpert-F1 of 0.549, RadGraph-F1 of 0.281, GREEN of 0.360, and RaTEScore of 0.604, outperforming the compared methods on most reported metrics, despite employing a substantially smaller LLM decoder. On CheXpert Plus, DRRG achieved the highest BLEU-4 (0.119) and CheXpert-F1 (0.347) among the compared methods. Conclusion: Discrete diffusion provides an effective alternative to autoregressive radiology report generation by enabling iterative, bidirectional report refinement. Incorporating clinically focused masking and image-derived concept conditioning improves report quality and clinical consistency.