Ultrasound acquisition requires skilled probe manipulation and real-time adjustments. Vision-language models (VLMs) could enable autonomous ultrasound systems, but existing benchmarks evaluate only static images, not dynamic procedural understanding. We introduce ReXSonoVQA, a video QA benchmark with 514 video clips and 514 questions (249 MCQ, 265 free-response) targeting three competencies: Action-Goal Reasoning, Artifact Resolution & Optimization, and Procedure Context & Planning. Zero-shot evaluation of Gemini 3 Pro, Qwen3.5-397B, LLaVA-Video-72B, and Seed 2.0 Pro shows VLMs can extract some procedural information, but troubleshooting questions remain challenging with minimal gains over text-only baselines, exposing limitations in causal reasoning. ReXSonoVQA enables developing perception systems for ultrasound training, guidance, and robotic automation.
Figures & tables
Figure 1: A ReXSonoVQA example: Type 3 (Procedure Context & Planning, Free-Response) question requiring identification of the screening objective and anatomical transition during a transverse sweep. Gemini 3 Pro correctly identifies the anatomical transition (tendon to muscle) but fails to specify the correct screening objective, receiving a partial score (1/2). More MCQs and free-responses examples see Appendix B .
Benchmark
Modality
# Items
Diagnosis
US- Specific
Multi- Organ
Dynamic Reasoning
MCQ
Free- Response
Blind Baseline
MedMCQA
Text
193,155
✓
✗
✓
✗
✓
✗
✗
GMAI-MMBench
Image
26,000
✓
✗
✓
✗
✓
✗
✗
OmniMedVQA
Image
127,995
✓
✗
✓
✗
✓
✗
✗
VQA-RAD
Image
3,515
✓
✗
✓
✗
✓
✓
✗
ReXVQA
Image
696,000
✓
✗
✗
✗
✓
✗
✗
ReXrank
Image
600,000+
✓
✗
✗
✗
✗
✓
✗
Table 1: Comparison of ReXSonoVQA with existing medical vision-language benchmarks. Dynamic Reasoning : Requires understanding of temporal processes, actions, and causal relationships. Diagnosis : Evaluates pathology identification or diagnostic interpretation. Blind Baseline : Includes text-only evaluation to verify questions require visual input. ✓ indicates present; ✗ indicates absent.
Figure 2: End-to-end pipeline for constructing ReXSonoVQA: (1) Task Definition, (2) Data Curation & Ground Truth Construction, (3) Prompt Refinement and Quality Control Loop, and (4) Benchmark Construction & Evaluation.
Figure 3: Example of video preprocessing. We crop the original video frame to retain only the ultrasound image stream, excluding surrounding content.
Figure 4: Examples from ReXSonoVQA. Left: Time-aligned procedural events derived from instructional narration. Right: A clip-grounded question-answer item targeting action-goal reasoning.
Figure 5: ReXSonoVQA dataset composition (514 items). Distribution of questions across clinical categories by task type.
Figure 6: Multi-model zero-shot MCQ accuracy (%, left) and free-response mean score (0–2 rubric, right) by task type under paired evaluation settings. Dashed red line marks 25% random chance for MCQ.
Figure 7: Multi-model zero-shot MCQ accuracy (%, left) and free-response mean score (0–2 rubric, right) by video duration under paired evaluation settings. Dashed red line marks 25% random chance for MCQ.
Appendix figures & tables19 assets
Supplementary material from the paper’s appendix.
Appendix
Figure A1: Prompt template used for QA generation.
Figure A2: Prompt template used for QA generation (continued).
Figure A3: Prompt template used for MCQ distractor refinement.
Figure A4: Prompt template used for model inference.
Figure A5: Prompt template used for LLM-as-a-judge.
Figure A6: Exploratory evaluation. Demonstrated why GPT-5.2 and Claude Opus 4.5 were excluded from our benchmark’s baseline. Without native video support, both models hallucinate completely unrelated anatomical structures (colon/intussusception and vein/thrombosis) when provided with sequential images, scoring 0/2. In contrast, Gemini 3 Pro with native video understanding correctly identifies the anatomical transition, achieving 1/2. This stark difference motivated our focus on models with native video support.
Figure A7: Case Study 1 (Free-Response, Type 1: Action–Goal Reasoning). Gemini 3 Pro correctly identifies the probe maneuver and acquisition target.
Figure A8: Case Study 2 (Free-Response, Type 2: Artifact Resolution & Optimization). Gemini 3 Pro hallucinates a compression maneuver instead of the actual optimization action.
Figure A9: Case Study 3 (MCQ, Type 1: Action–Goal Reasoning). Gemini 3 Pro misinterprets compression behavior due to incorrect anatomy identification, leading to the wrong action–goal selection.
Figure A10: Case Study 4 (MCQ, Type 2: Artifact Resolution & Optimization). Gemini 3 Pro fails to identify the color bleeding artifact and the corresponding optimization cue.
Figure A11: Case Study 5: (MCQ, Type 3: Procedure Context & Planning) fails to recognize the vertebral acoustic shadow as the key landmark for protocol context.
Computer Aided Medical Procedures (CAMP), TU Munich, Germany · Munich Center for Machine Learning (MCML), Munich, Germany · Zhongshan Hospital, Fudan University, China +1